8431 Murphy Drive Middleton, WI 53562
Telephone: 608-836-4400 Facsimile: 608-831-9279 www.intertek.com/building
TEST REPORT FOR HY-C COMPANY, LLC Report No.: 104415176MID-002AR2 Date: 11/09/21
REPORT ISSUED TO HY-C COMPANY, LLC 10950 Linpage Place St Louis, MO 63132 SECTION 1 SCOPE
Intertek Building & Construction (B&C) was contracted by HY-C Company, LLC to perform testing in accordance with EPA 40 CFR Part 60, “Standards of Performance for New Residential Wood Heaters, New Residential Hydronic Heaters and Forced-Air Furnaces,” ASTM E2515-11, "Standard Test Method for Determination of Particulate Matter Emissions Collected by a Dilution Tunnel," CSA B415.1-10, "Performance Testing of Solid-Fuel-Burning Heating Appliances", and ALT-134 EPA Alternate Test Method Letter, issued by the U.S. EPA on August 19, 2019. Results obtained are tested values and were secured by using the designated test method(s). Testing was conducted at Intertek test facility in Middleton, WI. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. SECTION 2 SUMMARY OF TEST RESULTS The appliance tests resulted in the following performance: Particulate Emissions: 0.14 lb/MMBtu Output Carbon Monoxide Emissions: 1.73 g/min
Heating Efficiency: 40.27% (Higher Heating Value Basis – Direct Output) Heating Efficiency: 69.57% (Higher Heating Value Basis – Stack Loss)
For INTERTEK B&C: COMPLETED BY: Ken Slater
REVIEWED BY: Brian Ziegler
Associate Engineer - Hearth
Technical Team Leader - Hearth
TITLE:
TITLE:
SIGNATURE:
SIGNATURE:
DATE:
DATE:
11/09/21
11/09/21
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample(s) tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
Version: 03/13/18
Page 2 of 25
RT-L-AMER-Test-3778
Made with FlippingBook - professional solution for displaying marketing and sales documents online