Philip Payne

195

MULTI-ZONE SPECTOWEB | PHILIP PAYNE UP TO 64 CONNECTED LUMINAIRES/SIGNS

3A fused unswitched mains supply

3A fused unswitched mains supply

Transmits test results to the SpectoWeb monitoring website

e-mails of test reports sent to authorised personnel

Transmits test results to the SpectoWeb monitoring website

e-mails of test reports sent to authorised personnel

SpectoWeb Controller

SpectoWeb Controller

Specto Distribution Terminal

CANbus Data Circuit

WWW

WWW

SpectoController to Luminaire + DALI

DALI Data Circuit

DALI Data Circuit

Mains in

Unswitched Mains Local Lighting Sub-Circuit 1

Unswitched Mains Local Lighting Sub-Circuit 1

SpectoWeb Luminaire

SpectoWeb Luminaire

SpectoWeb Luminaire

SpectoWeb Luminaire

SpectoWeb Luminaire

SpectoWeb Luminaire

Zone 1 Maximum 64 luminaires

Zone 1 does not reqire a separate SZT or SDT

Unswitched Mains Local Lighting Sub Circuit 2

Unswitched Mains Local Lighting Sub Circuit 2

Unswitched mains supply

RJ45 to SZT

to SpectoController or next SDT

SDT

DALI Data Circuit

SpectoWeb Luminaire

SpectoWeb Luminaire

SpectoWeb Luminaire

SpectoWeb Luminaire

SpectoWeb Luminaire

SpectoWeb Luminaire

SpectoWebDistribution Terminal (SDT)

SDT

Zone 2 Maximum 30 Luminaires 1 x SDT & SZT required

LUMINAIRES - up to 30 per SDT max.

SpectoWebZone Terminal (SZT)

Unswitched Mains Local Lighting Sub-Circuit 3

Unswitched Mains Local Lighting Sub-Circuit 3

Unswitched mains supply

DALI Data Circuit

Specto Zone Terminal

SpectoWeb Luminaire

SpectoWeb Luminaire

SpectoWeb Luminaire

SpectoWeb Luminaire

SpectoWeb Luminaire

SpectoWeb Luminaire

SpectoWebDistribution Terminal (SDT)

Zone 3 Maximum 30 Luminaires 1 x SDT & SZT required

Key switch

SpectoWebZone Terminal (SZT)

Specto Distribution Unit

= Junction Box

= Junction Box • 230V supply cables are 1.5mm² - 2.5mm² • DALI data circuits run directly from SpectoWeb controller to luminaires - DALI cables are 1.0mm² or 1.5mm² two core mains rated (please do not use mains cable colours)

• 230V supply cables are 1.5mm² - 2.5mm² • CANbus data circuit runs from the SpectoWeb Controller to the SDT’s - CANbus cabels are a special specification (please contact Phillip Payne Ltd.) - Maximum total CANbus circuit cabel length = 1000m - CANbus Data Circuits are polarity sensitive - DONOT CROSS CONNECTWIRES

Specto Zone Terminal

TonextSDT

- 1.0mm² = 200mmaximum cable length - 1.5mm² = 300mmaximum cable length - DALI data circuits are non-polarity sensitive

• DALI data circuits run from SDT’s to Luminaires - DALI cabels are 1.0mm² or 1.5mm² two core mains rated (please do not use mains cable colours)

• Maximum 64 luminaires in SINGLE ZONE

- 1.0mm² = 200mmaximum cable length per zone - 1.5mm² = 300mmaximum cable length per zone - DALI data circuits are non-polarity sensitive

• Maximum 50 zones. 1 x SDT and SZT are required per zone (except Zone 1 - no SDT or SZT required) • Maximum 30 luminaires per zone (except Zone 1 - maximum 64 luminaires)

Made with FlippingBook - Online Brochure Maker