catalog PowerSafe

Amphenol Socapex │ POWERSAFE

POWERSAFE / VG96944 - JAM NUT REDUCED FLANGE RECEPTACLE

Reduced flange receptacles are derived from 38999 series III Jam nut receptacles and dedicated for applications where size & weight are critical, offering un smaller footprint and higher contact density

Main features

With Castle nut *

- For Jam nut receptacle (TV07/TVS07). - Higher density on panel: 41% average footprint surface less. - Lighter: 20% average lighter than standard 38999 - Mates with standard Power Safe plug and caps. - Matches the Power Safe performances. - Improved design of the o’ring groove allowing the o’ring to stay in place.

* Please consult us if you need a safety catle nut with lock (wiring possibility)

MATED PAIR

RECEPTACLE FRONT FACE

Jam nut Receptacle TV*07***

Reduced flange Receptacle TV*07***F312

Footprint savings Average 41% footprint reduction:

Reduced flange Receptacle F312

PowerSafe Reduced flange (F312) ØB MAX (mm)

Jam nut Receptacle

Standard PowerSafe ØA MAX (mm)

Size

Ø Reduction

13 15 17 21 23 25

38.4 41.6 44.8 52.7 55.9

28.1 32.1 36.1 41.1 44.1 48.1

46% 40% 35% 39% 38% 34%

59

All others dimensions remain the same in jam nut or reduced flange receptacles (lengths, threads, etc.). See page 13 for all other receptacle dimensions Panel hole dimensions

ØG +0.1 0

H +0.1 0 22.3 25.5 30.3 35.1 38.3 41.5

E recommended

Size

13 15 17 21 23 25

31.4 34.5 37.7 43.7 46.9 51.0

23 27 31 36 39 43

Tooling

Specific tightening tool for castle nut

Size

Tool reference

13 15 17 21 23 25

809683 809684 809685 809687 809688 809689