Amphenol Socapex │ POWERSAFE
POWERSAFE / VG96944 - JAM NUT REDUCED FLANGE RECEPTACLE
Reduced flange receptacles are derived from 38999 series III Jam nut receptacles and dedicated for applications where size & weight are critical, offering un smaller footprint and higher contact density
Main features
With Castle nut *
- For Jam nut receptacle (TV07/TVS07). - Higher density on panel: 41% average footprint surface less. - Lighter: 20% average lighter than standard 38999 - Mates with standard Power Safe plug and caps. - Matches the Power Safe performances. - Improved design of the o’ring groove allowing the o’ring to stay in place.
* Please consult us if you need a safety catle nut with lock (wiring possibility)
MATED PAIR
RECEPTACLE FRONT FACE
Jam nut Receptacle TV*07***
Reduced flange Receptacle TV*07***F312
Footprint savings Average 41% footprint reduction:
Reduced flange Receptacle F312
PowerSafe Reduced flange (F312) ØB MAX (mm)
Jam nut Receptacle
Standard PowerSafe ØA MAX (mm)
Size
Ø Reduction
13 15 17 21 23 25
38.4 41.6 44.8 52.7 55.9
28.1 32.1 36.1 41.1 44.1 48.1
46% 40% 35% 39% 38% 34%
59
All others dimensions remain the same in jam nut or reduced flange receptacles (lengths, threads, etc.). See page 13 for all other receptacle dimensions Panel hole dimensions
ØG +0.1 0
H +0.1 0 22.3 25.5 30.3 35.1 38.3 41.5
E recommended
Size
13 15 17 21 23 25
31.4 34.5 37.7 43.7 46.9 51.0
23 27 31 36 39 43
Tooling
Specific tightening tool for castle nut
Size
Tool reference
13 15 17 21 23 25
809683 809684 809685 809687 809688 809689
All dimensions are given for information only and are in mm, except as otherwise specified │ *in mm: 1mm=0.03937 inch
Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex