Catalog PCB connectors SIAL SIHD

SIAL PCB connector is a modular high-density interconnection system developed by Amphenol Socapex for use in severe environments, such as commercial and military aerospace and C5ISR applications. This hybrid connector is designed to work with thermal clamps and exceeds MIL-DTL-55302 requirements, making it a robust and reliable technology. SIAL comes in 13 different arrangements with 18 to 392 contacts.

SIAL / SIHD CONNECTORS

I

AMPHENOLSOCAPEX.COM

OUR RESOURCES

Access everything you need to simplify your projects. More than just a technical guide, our catalog opens the door to a multitude of services and practical tools. All the information below is available on our website or by clicking on the digital PDF.

CAD FILES & PRODUCT SELECTOR Streamline your design process with our 3D connector models. Downloadable in many formats.

FIND PRODUCT AVAILABILITY AT OUR DISTRIBUTORS With your part number, find product availability in just a few clicks!

TECHNICAL SUPPORT We’ll answer all your questions.

ONLINE QUOTATION Simply fill out our online form to receive your pricing

PRODUCT ASSEMBLY VIDEO

TECHNICAL CATALOGS

PRODUCT FAQ Answers to your most important questions.

OUR CERTIFICATIONS

MY AMPHENOL Follow our orders and delivery dates

EXPORT CONTROL CLASSIFICATION

2

OUR OFFER

38999 SERIES

RUGGED ETHERNET, USB & DISPLAY CONNECTORS

2M MICRO MINIATURE

ACCESSORIES

PT/451 - 26482 SERIES

SL61 & SOCA

RFM SERIES

PCB CONNECTORS

FIBER OPTIC SOLUTIONS

CONTACTS

ETHERNET SWITCH & MEDIA CONVERTER

USB KEYS & EXTENDERS

PS SERIES : Power Devices Solutions

CORDSETS & JUMPERS

CABLE ASSEMBLY

HARNESS IN THE BOX

From cable assembly to customized solutions, we’re here to add value to your projects. We look forward to hearing from you. CUSTOMIZED PRODUCTS AND SOLUTIONS

CONSULT US

3

OUR COMPANY

Since 1947, Amphenol Socapex has prescribed, designed and manufactured reliable and innovative interconnection solutions for harsh environments, specializing in standard and customized electrical and fiber optic connectors, contacts, accessories and cabling solutions. Amphenol Socapex, based in the Mont Blanc region of France and with operations in India and Tunisia, has a global presence in over 100 countries.

OUR MARKETS

BATTLEFIELD COMMUNICATION

GROUND VEHICLES

MILITARY AIRCRAFT / STRUCTURE

COMMERCIAL AVIATION

OTHERS

4

TECHNOLOGIES & INNOVATIONS RESEARCH & DEVELOPMENT

» ENGINEERING LABORATORY: 320m2 state-of-the-art facilities in France and India with advanced testing and analysis equipment. » EXPERTISE: 30+ specialists handling 300+ product tests and 1,400+ metrology requests annually. » TECHNOLOGY : Plating engineering, material development, high voltage analysis, 3D EM simulation, fiber optics, and assembly. » METROLOGY: Internal verification of the conformity of measuring instruments and ensuring that our measurement management system complies with the recommendations of ISO 10012.

OUR WORKSHOPS

Our workshops located in France & India provide consistent quality adapted to your volume requirements. » MOLDING: Solid expertise in thermoplastic elastomer and thermoset molding » MACHINING: Manufacturing of cylindrical shells and rectangular shells » SCREW MACHINING: Manufacturing of electrical contacts » PLATING: Plating with cadmium, nickel, electroless nickel, silver, black zinc nickel, gold » ASSEMBLY: Connector and harness assembly (electrical & optical) » AUTOMATION & TOOLING: Tools for our different activities : molding, machining, assembly

JOIN US ! WE’RE HIRING

5

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

6

Amphenol Socapex │ SIAL-SIHD

Table of Contents About Amphenol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 SIAL - The hybrid connector for use with thermal clamps SIAL product range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Signal contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Special contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Signal modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Hybrid modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Fittings and guiding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Keying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Realignment capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Mating sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 SIAL signal version typical arrangements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 SIAL signal version layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 SIAL coaxial version typical arrangements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 SIAL coaxial version layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Tooling.............................................................................................................. 24 SIHD - The monolithic connector for use with thermal clamps SIHD product range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Female signal contacts for plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Malesignalcontactsforreceptacles.................................................................................. 31 Groundstrips........................................................................................................ 31 Guiding / Keying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Mating sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Realignment capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Fixing accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 SIHD without ground strip typical arrangements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 SIHDwithgroundstriptypicalarrangements......................................................................... 35 SIHD without ground strip layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 SIHDwithgroundstriplayouts....................................................................................... 37

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

7

Amphenol Socapex │ SIAL

SIAL

The hybrid connector for use with thermal clamps

SIAL is a modular high density interconnection system that has the capability to mix signal and coax contacts. The contact technology developed for this connector allows the use of thermal clamps. With 3 sizes of modules, the SIAL connectors provide the arrangement needed, from 18 to 392 contacts. In a staggered grid pattern (2.54 x 1.905 [.100x.075]), this connector houses 5 rows of contacts in a low prole board to board format. Additionally, SIAL connectors provide shielding on both plug & receptacle, which allows the dissipation of all the electrical charge while mating.

The concept 3 standard modules are available with 18, 58 and 98 signal contacts on 5 rows. These allow arrangements up to 392 contacts. The various modules are maintained in a metallic shell, allowing both protection of male contacts on the plug, and a mix of signal and coax modules. Compatible with the use of thermal clamps Its standard contact technology, already used in the monolithic SIHD connector, permits the lateral displacement (±0.25 [.010]) of the pin into the socket without generating any stress on the contact termination on the PCB. This feature allows the use of thermal clamps to keep the daughter board in position after mating, as well as the dissipation of energy generated by the components on the board from the heat sink (thermal drain) to the cold wall (liquid cooled) or to the chassis. The locking of the thermal clamps provides the lateral movement of the plug into the receptacle. The SIAL allows this lateral displacement of ±0.25 [.010] without creating stress on the solder joints or on the contact area. A complete range for test, programming, maintenance E = Female receptacle for mother board F = Male plug for daughter board T = Female test receptacle for daughter board S = Male test plug P = Female extender receptacle

QUICK SELECTION GUIDE

Signal contacts 

Coax contacts 

Modules 

Fittings & Guiding 

Keying 

FEMALE MALE for receptacles for plugs

FITTING

COAX SIZE 12

NUMBER OF SIGNAL CONTACTS 018, 036, 058, 076, 098, 116, 156, 196, 214, 254, 312, 370, 392 NUMBER OF COAX CONTACTS Size 12: 03 Size 16: 05, 10

5 polarizing pins / connector

COAX SIZE 16

for extender receptacles

FEMALE SOCKET GUIDE

3 COAX / MODULE

5 COAX / MODULE

MALE GUIDE PIN

for test plugs

PAGE 13 PAGE 12

PAGE 14

PAGE 16

PAGE 17

PAGE 17

The SIAL series serves various markets, including:

Commercial avionics & airframe

Military avionics & airframe

Space

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

8

Amphenol Socapex │ SIAL

SIAL Series

Lateral displacement compatibility

Table of contents

SIAL product range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Signal contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Special contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Signal modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Hybrid modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Fittings and guiding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Keying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Realignment capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Mating sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

SIAL signal version typical arrangements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 SIAL signal version layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

SIAL coaxial version typical arrangements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 SIAL coaxial version layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Tooling.............................................................................................................. 24

The SIAL series serves various markets , including:

Commercial Avionics & Airframe

Military Avionics & Airframe

Space

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

9

Amphenol Socapex │ SIAL

SIAL>>> GENERAL SPECIFICATIONS

MEDIUM DENSITY

• Modular connector mixing signal and coax contacts in many arrangements • Lateral displacement capability allowing the use of thermal clamps: ± 0.25 [ ± .010] • Complete range for test, programming and maintenance • Designed for severe mechanical environments • 2.54 [.100] staggered grid (1.27 [.050] oset), 1.905 [.075] between rows

Markets

Main characteristics •

Medium density: 0.14 cts/mm² [90 cts/inch²]

• 13 arrangements on 5 rows of contacts, from 18 to 392 signal contacts • 6 hybrid arrangements mixing coax and signal contacts • 3 A per signal contacts / DWV: 750 Vrms • Lateral rails to protect the male contacts from external damage • Repairable contacts for easy maintenance

Main applications

Recommended congurations

Terminations

Standard

CECC 75101-012

MIL-DTL-55302

How to order

000 500

No coaxial contact / standard

Coax after signal contacts

NX KX

NT KT

16 12

For receptacle (E, P / T)

501*

5 right & 5 left coax, for size 156 only

T Female test receptacle S Male test plug P Female extender receptacle E Female receptacle F Male plug Connector type

502 000

Coax before signal contacts

No coaxial contact

Blank

C

E, F / T

Coax after signal contacts

Female receptacle (E, P / T)

Male plug (F / S)

For plug (F / S)

001*

5 right & 5 left coax, for size 156 only

Size

Blank

P / S

002

Coax before signal contacts

Coaxial module

Deviation

Fitting

Termination plating Tin lead Blank Lead free LF

---

ASL -

---

---

-

--

---

-

--

Number of signal contacts

Signal contact type (see pages 12 to 13)

Number of coax contacts Size Number of coax

Signal contacts only

Mix of signal & coaxial contacts 018 (+3) 058 (+3) or (+5) 098 (+3)

Male contacts (for F)

Male contacts (for S)

Female contacts (for E)

Female contacts (for P / for T)

No coaxial contact

Blank

156 196 214 254 312 370 392

Straight PC tail

Y04

Y04

Y09 or Y19

018 036 058 076 098 116

03

Size 12 Size 16

90° PC tail Y01 or Y02 Y03 or Y02

Y01 or Y02 U04, U05, U06, U07 or U08

05 or 10 for size 156*

156 (+10) 196 (+5) * 254 (+5) *

U04, U05, U06, U07 or U08

SMT

* For standard application (P, E, F) only

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

10

Amphenol Socapex │ SIAL

SIAL>>> TECHNICAL SPECIFICATIONS

Dimensional characteristics

L= 22.86[.900] to 231.14[9.100] for signal version L= 53.34[2.100] to 180.34[7.100] for hybrid version A= 12.1 MAX [.476] H= 6.41 MAX [.252] for plug H= 10.26 MAX [.404]

L

Female contact

Male contact

Cross cavity by Amphenol: lateral displacement compatible • Cross section of the lateral displacement of the male contact inside the female cavity • Maintains 2 points of contact • Allows a ± 0.25 [± .010] lateral displacement • No stress on solder joints or on the contact area L

Mating end size: 0.6 x 1.2 [.047 x .024]

Contact section (mating side) : 0.72mm² [.001 in²]

Material: beryllium copper (stamped)

Plating: •

Material: beryllium copper (stamped)

Termination: tin lead or lead free Active contact area: gold over nickel

•

Plating: •

Termination: tin lead or lead free Active contact area: gold over nickel

Materials •

•

Fixing devices: anodized aluminium Guiding devices: passivated stainless steel Polarizing pins: passivated stainless steel Metallic rails: passivated stainless steel

• • • •

Plastic inserts: thermoset DAP, 30% glass-fiber filled

MECHANICAL CHARACTERISTICS Backo  1 (mm) Mating force per contact (N) Unmating force per contact (N)

< 0.8 [.031]

1 : When both connectors are fully mated, the backoff is the maximum distance the connectors can be unmated while functioning properly

0.58 MAX

0.16 < F < 0.58

Durability cycles 500 Sinusoidal vibrations (10 to 2000 Hz) micro discontinuity 2ns 10 g Random vibrations (10 to 2000 Hz) micro discontinuity 2ns 0.15 g² / Hz Shocks micro discontinuity 1ns 100 g ENVIRONMENTAL CHARACTERISTICS Thermal shocks (°C) -55 / +125 Salt Spray (hours) 144* or 96

ELECTRICAL CHARACTERISTICS Current rating per contacts (A)

3

Insulation resistance (at 500Vdc) (GΩ)

5 MIN

Contact resistance (mΩ)

25 MAX

Dielectric Withstanding Voltage (Vrms) Capacitance between contacts (pF)

750

1.5 MAX

Service voltage (at 50 Hz) (Vrms)

250

* “C” standard version

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

11

Amphenol Socapex │ SIAL

SIAL >>> SIGNAL CONTACTS (  ) MALE CONTACTS FOR PLUGS

Right angle PC tail

Right angle PC tail

- Thru hole soldering - Daughter board - PCB thickness: 3.1 MAX [.122]

- Thru hole soldering - Daughter board - PCB thickness: 2.6 MAX [.102]

L

L

Y01

Y02

Termination style

Termination style

SMT double side PCB, centered

Straight PC tail

L

L

L

- SMT soldering - Double-sided daughter board, centered - PCB thickness: 2.6 ± 0.235 [.102 ± .009]

- Thru hole soldering - Daughter board - PCB thickness: 4.5 ± 0.45 [.177 ± .018]

L

L

A

A

Plan originel ECHELLE

DESSIN: BOTOMA le

Plan originel ECHELLE

DESSIN: BOTOMA le

Amphenol Socapex

Amphenol Socapex

Y04

U04

Termination style

Termination style

1,000

TECHNIQUE:

1,000

TECHNIQUE:

BP 29 - 74311 THYEZ CEDEX

BP 29 - 74311 THYEZ CEDEX

1/1

1/1

SMT double side, centered

SMT double side, centered

A

Plan originel ECHELLE

DESSIN: BOTOMA le

Amphenol Socapex

- SMT soldering - Double-sided daughter board, centered - PCB thickness: 1.6 ± 0.160 [.063 ± .006]

1,000

TECHNIQUE:

1/1 - SMT soldering - Double-sided daughter board, centered - PCB thickness: 2 ± 0.2 [.079 ± .008]

BP 29 - 74311 THYEZ CEDEX

L

L

U06

Termination style

U05

Termination style

Plan originel ECHELLE

DESSIN: BOTOMA le

Amphenol Socapex

1,000

TECHNIQUE:

BP 29 - 74311 THYEZ CEDEX

1/1

SMT double side, o centered

SMT double side, o centered

L

L

L

- SMT soldering - Double-sided daughter board, offset - PCB thickness: 2.44 ± 0.42 [.096 ± .016]

- SMT soldering - Double-sided daughter board, offset - PCB thickness: 2.6 ± 0.235 [.102 ± .009]

L

L

U07

Termination style

U08

Termination style

A

Plan originel ECHELLE

DESSIN: BOTOMA le

Plan originel ECHELLE

DESSIN: BOTOMA le

Amphenol Socapex

Amphenol Socapex

1,000

1,000

TECHNIQUE:

TECHNIQUE:

BP 29 - 74311 THYEZ CEDEX

BP 29 - 74311 THYEZ CEDEX

1/1

1/1

Y01

Y02

Y04

U04

U05

U06

U07

U08

4.2 ± 0.2 [.165 ± .008] Plan originel ECHELLE

3.7 ± 0.2 [.146 ± .008] Amphenol Socapex

2.6 ± 0.235 [.102 ± .009]

2 ± 0.2 [.079 ± .008]

A 1.6 ± 0.160 [.063 ± .006]

2.44 ± 0.42 [.096 ± .016]

2.6 ± 0.235 [.102 ± .009]

L MAX

6 [.236] DESSIN: BOTOMA le

A

Plan originel ECHELLE

DESSIN: BOTOMA le

Amphenol Socapex

1,000

1,000

TECHNIQUE:

TECHNIQUE:

Termination section

Ø 0.4 ± 0.03 [.016 ± .001] BP 29 - 74311 THYEZ CEDEX

0.3 x 0.8 [.012 x .031]

BP 29 - 74311 THYEZ CEDEX

1/1

1/1

Mating end size

1.2 x 0.6 [.047 x .024] 2 [.079] Ni + 1[.039] Au

Active contact area plating µm[µin]

2 [.079] Ni + 3 [.118] SnPb or bright pure Sn for RoHS version

2 [.079] Ni + 7 [.276] SnPb or bright pure Sn for RoHS version

Termination plating µm [µin]

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

12

Amphenol Socapex │ SIAL

SIAL>>> SIGNAL CONTACTS (  ) MALE CONTACT FOR TEST PLUGS

Right angle PC tail

L

- Thru hole soldering - Daughter board - PCB thickness: 1.6 ± 0.16 [.063 ± .006]

L

L

Y03

Termination style

FEMALE CONTACTS FOR RECEPTACLES

Straight PC tail, standard length

Straight PC tail, short length

L

L

- Thru hole soldering - Mother board - PCB thickness: up to 2 ± 0.2 [.079 ± .008]

- Thru hole soldering - Mother board - PCB thickness: 3.75 ± 0.75 [.148 ± .030]

A

A

Plan originel ECHELLE

DESSIN: BOTOMA le

Plan originel ECHELLE

Amphenol Socapex

Amphenol Socapex

Y09

Y19

Termination style

Termination style

1,000

1,000

TECHNIQUE:

BP 29 - 74311 THYEZ CEDEX

BP 29 - 74311 THYEZ CEDEX

1/1

FEMALE CONTACT FOR EXTENDER RECEPTACLES Right angle PC tail, short length

Right angle PC tail

- Thru hole soldering - Extender card - PCB thickness: 2.6 MAX [.102]

- Thru hole soldering - Extender card - PCB thickness 3.1 MAX [.122]

Y02

Y01

Termination style

Termination style

Y03

Y02

Y01

Y09*

Y09-010

Y19

2.8 ± 0.2 [.165 ± .008]

3.7±0.2 [.146 ± .008]

4.2 ± 0.2 [.165 ± .008]

5,75 ± 0,25 [.226 ± .010]

4,5 ±0.2 [.177 ± .008]

3.7 ± 0.3 [.146 ± .012]

L MAX

Mating end size

1.2 x 0.6 [.047 x .024]

Termination section

Ø 0.4 ± 0.03 [.016 ± .001]

Ø 0.5 ± 0.03 [.020 ± .001]

Active contact area plating µm[µin]

2 [.079] Ni + 1[.039] Au

Termination plating µm [µin]

2 [.079] Ni + 3 [.118] SnPb or bright pure Sn for RoHS version

* for monobloc version ASLMxx, please consult us

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

13

Amphenol Socapex │ SIAL

SIAL>>> SPECIAL CONTACTS (  ) SIZE 16 COAXIAL CONTACTS

Male contacts for plugs – 5-cavity module

Straight crimp barrel

Straight PC tail - UT47

- For 5-cavity module - For UT47 semi-rigid cable - Size 16: 6 GHz depending on cable – 50 Ω

- For 5-cavity module - For 2 [.079] cable - Size 16: 6 GHz depending on cable – 50 Ω

320008

320033

2 [.079]

Consult us

Right angle PC tail

- For 5-cavity module - Size 16: 6 GHz depending on cable – 50 Ω

320032

Consult us

Female contacts for receptacles – 5-cavity module

Straight crimp barrel

Straight PC tail - UT47

- For 5-cavity module - For 2, 1.2, 2.7 or 2.4 cable [for .079, .047, .106 or .094 cable] - Size 16: 6 GHz depending on cable – 50 Ω

- For 5-cavity module - For UT47 semi-rigid cable - Size 16: 6 GHz depending on cable – 50 Ω

320009 320011 320017 320018

2 [.079] 1.2 [.047] 2.7 [.106] 2.4 [.094]

320006

Consult us

Straight PC tail - Sucoform

- For 5-cavity module - For Sucoform cable 0.086 [.003] - Size 16: 6 GHz depending on cable – 50 Ω - No lateral displacement

320021

Consult us

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

14

Amphenol Socapex │ SIAL

SIAL >> SPECIAL CONTACTS (  )

SIZE 12 COAXIAL CONTACTS

Male contacts for plugs – 3-cavity module

Right angle PC tail

Straight crimp barrel

- For 3-cavity module - Size 12: 0 to 3 GHz – 50 Ω - Standard designation: M39029 / 28 - 211

- For 3-cavity module - Size 12: 0 to 3 GHz – 50 Ω

900340

320000

Consult us

Consult us

Female contacts for receptacles – 3-cavity module

Right angle crimp barrel – KX22A

Right angle crimp barrel – F 1703/66

- For 3-cavity module - For KX22A cable - Size 12: 0 to 3 GHz – 50 Ω

- For 3-cavity module - For F 1703 / 66 cable - Size 12: 0 to 3 GHz – 50 Ω

320001

320004

Consult us

Consult us

Straight PC tail

Straight crimp barrel

- For 3-cavity module - For test only, specific application

- For 3-cavity module - Standard designation: M39029 / 27 - 210

- Size 12: 0 to 3 GHz – 50 Ω - No lateral displacement

- Size 12: 0 to 3 GHz – 50 Ω - With lateral displacement

320002

900354

Consult us

Consult us

16-SIZE CONTACT

12-SIZE CONTACT

Impedance Ω

50

50

Voltage rating V

180

180

Current rating mA

500

500

Contact retention N

≥ 50

≥ 50

Frequency range GHz

0 to 1

0 to 1

Contact resistance mΩ

≤ 12

≤ 12

VSWR at 1 GHz

1.3 MAX

1.3 MAX

Insertion and extraction force per contact N Dielectric and extraction force per contact N

1 ≤ F ≤ 15

1 ≤ F ≤ 15

at sea level, 1000 V. at 15240 m, 250 V.

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

15

Amphenol Socapex │ SIAL

SIGNAL MODULES SIAL >> MODULES (  )

18 signal contacts

58 signal contacts

- Arrangement available: - 18 - 18 x 2 = 36 - 18 + 58 = 76

- Arrangement available: - 58

L

- 58 + 18 = 76 - 58 x 2 = 116 - 58 + 98 = 156

l

L

L

- 58 x 2 + 98 = 214 - 58 + 98 x2 = 254 - 58 x 2 + 98 x 2 = 312 - 58 x 3 + 98 x 2 = 370

l

l

L

L

L

98 signal contacts

l

l

L - Arrangement available: - 98 - 98 + 58 = 156 - 98 x 2 = 196

l

L

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

5,000

TECHNIQUE:

BP 29 - 74311 THYEZ CEDEX

1/1

l

l

BP 29 - 74311 THYEZ CEDEX - 98 x 2 + 58 x 2 = 312 - 98 x 2 + 58 x 3 = 370 - 98 x 4 = 392 Amphenol Socapex 5,000 TECHNIQUE: - 98 + 2 x 58 = 214 - 98 x 2 + 58 = 254

L

A

Plan originel ECHELLE

DESSIN: le

l

1/1

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

5,000

TECHNIQUE:

BP 29 - 74311 THYEZ CEDEX

1/1

HYBRID MODULES

L

3 coax contacts – size 12

5 coax contacts – size 16

l

- 3-cavity module for 12-size coaxial contact - Arrangement available:

- 5-cavity module for 16-size coaxial contact - Arrangement available: - 5 x 2 + 98 + 58 - 5 x 2 + 98 x 2 - 5 x 2 + 98 x 2 + 58

- 3 + 18 - 3 + 58 - 3 + 98

L

L

l

l

L

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

2,000

TECHNIQUE:

l

BP 29 - 74311 THYEZ CEDEX

1/1

18 signal contacts 58 signal contacts 98 signal contacts 3 coax contacts

5 coax contacts

L

10.16 [.400]

30.48 [1.200]

50.8 [2.1000]

25.4 MAX [1.000]

A

Plan originel ECHELLE

DESSIN: le

l Receptacle Plug

Amphenol Socapex

2,000

TECHNIQUE:

BP 29 - 74311 THYEZ CEDEX

10.05 [.396] 10.8 [.425]

9.95 [.392] 10.8 [.425]

1/1

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

16

Amphenol Socapex │ SIAL

SIAL>>> FITTINGS/GUIDING & KEYING (  &  ) FITTINGS / GUIDING   

A- centered end ttings

B- end ttings

- 1 centered end fitting at one end of the connector - Max length: 6, 35 [.250]

- 1 end fitting at one end of the connector - Max length: 6, 35 [.250] - Male guide pin on receptacle - Offset hole on plug - 4 holes for polarizing pin

- Male guide pin on receptacle - Female centered hole on plug - 4 holes for polarizing

Central ttings

A

BP 29 - 74311 THYEZ CEDEX - Max length: 6, 35 [.250] - Guiding device: Male guide pin on receptacle - 2 holes for polarizing pin Signal version - 1 fitting for 196, 214, 254 and 312 positions Plan originel ECHELLE Amphenol Socapex DESSIN: le 3,000 TECHNIQUE: 1/1

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

3,000

TECHNIQUE:

BP 29 - 74311 THYEZ CEDEX

1/1

With coaxial contacts - 1 fitting for 18 + 3, 58 + 3 and 98 + 5 positions - 2 fittings for 98 + 58 + 5 x 2 positions

- 2 fittings for 370 positions - 3 fittings for 392 positions

Polarizing pins KEYING   

- 2 pins at each end fitting for the plug / 2 pins at each end fitting for the receptacle - 1 pin at each central fitting for the plug / 1 pin at each central fitting for the receptacle - Identification of keying cavities: clockwise for the plugs, counterclockwise on the receptacle - A,B,C,D on A fitting, W,X,Y,Z on B fitting

REALIGNMENT CAPABILITY

In the longitudinal axis

In the lateral axis

MATING SEQUENCE

Shell guiding

Coax guiding

Keying

Coax contact

Signal contact

Housing contact

6.27 ± 0.36 [.247 ± .014] 0.24 ± 0.6 [.009 ± .024] 3.7 ± 0.7 [.121 ± .028]

6.56 ± 0.45 [.258 ± .018] 3.3 ± 0.6 [.130 ± .024]

3.26 ± 0.6 [.128 ± .024] 3.3 ± 0.6 [.130 ± .024]

2.14 ± 0.28 [.084 ± .011] 2.9 ± 0.6 [.114 ± .024]

6.8 ± 0.45 [.268 ± .018]

2.14 ± 0.28 [.084 ± .011]

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

17

Amphenol Socapex │ SIAL

SIAL>> SIGNAL VERSION (  ) TYPICAL ARRANGEMENTS

18 signal contacts

36 signal contacts

58 signal contacts

76 signal contacts

EXPORT CONTROL CLASSIFICATION :NOT CONTROLLED/EAR99 Information contained in this document is not subject to Export Control Regulations of the European Union, USA or other countries. Each recipient of this document is responsible for ensuring that transfer or use of any information contained in this document complies with all relevant Export Control regulations and EAR99 regulations.

EXPORT CONTROL CLASSIFICATION :NOT CONTROLLED/EAR99 Information contained in this document is not subject to Export Control Regulations of the European Union, USA or other countries. Each recipient of this document is responsible for ensuring that transfer or use of any information contained in this document complies with all relevant Export Control regulations and EAR99 regulations.

98 signal contacts

116 signal contacts

EXPORT CONTROL CLASSIFICATION :NOT CONTROLLED/EAR99 Information contained in this document is not subject to Export Control Regulations of the European Union, USA or other countries. Each recipient of this document is responsible for ensuring that transfer or use of any information contained in this document complies with all relevant Export Control regulations and EAR99 regulations.

EXPORT CONTROL CLASSIFICATION :NOT CONTROLLED/EAR99 Information contained in this document is not subject to Export Control Regulations of the European Union, USA or other countries. Each recipient of this document is responsible for ensuring that transfer or use of any information contained in this document complies with all relevant Export Control regulations and EAR99 regulations.

a E D

a E D

156 signal contacts

FEMALE-116-WAYS

FEMALE-98-WAYS

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

A

Plan originel ECHELLE

DESSIN: le

5,000

TECHNIQUE:

Amphenol Socapex

4,000

TECHNIQUE:

1/1

1/1

a E D

FEMALE-156-WAYS

18

36

58

76

98

116

156

16.51 [.650] 22.86 [.900] 7.62 [.340]

A 26.67 [1.050] 33.02 [1.300]

DESSIN: le 36.83 [1.450] TECHNIQUE: 43.18 [1.700] 27.94 [1.100]

46.99 [1.850] 53.34 [2.100] 38.1 [1.500]

57.15 [2.250] 63.5 [2.500] 48.26 [1.900]

67.31 [2.650] 73.66 [2.900] 58.42 [2.300]

87.63 [3.450] 93.98 [3.700] 81.28 [3.200]

D

Plan originel ECHELLE

Amphenol Socapex

4,000

E MAX

1/1

17.78 [.700]

a

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

18

Amphenol Socapex │ SIAL

TYPICAL ARRANGEMENTS SIAL>> SIGNAL VERSION (  )

FEMALE-196-WAYS

FEMALE-214-WAYS

196 signal contacts

214 signal contacts

b

a

a

b

a'

b'

a'

b'

D

D

254 signal contacts

a

b

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

a'

b'

2,500

A

TECHNIQUE:

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

4,000

TECHNIQUE:

1/1

1/1

D

female-312-ways

FEMALE-254-WAYS

312 signal contacts

b

a

a'

b'

D

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

3,500

TECHNIQUE:

1/1

370 signal contacts

a

b

c

a'

b'

c'

FEMALE-392-WAYS

D

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

2,500

TECHNIQUE:

1/1

392 signal contacts

FEMALE-370-WAYS

a

b

c

d

b'

c'

d'

a'

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

D

2,500

TECHNIQUE:

1/1

196

214

254

312

370

392

D

113.03 [4.450] 119.38 [4.700] 48.26 [1.900] 56.515 [2.225] 48.26 [1.900] 56.515 [2.225]

123.19 [4.850] 129.54 [5.100] 81.28 [3.200] 86.995 [3.425] 27.94 [1.100] 36.195 [1.425]

143.51 [5.650] 149.86 [5.900] 81.28 [3.200] 86.995 [3.425] 48.26 [1.900] 56.515 [2.225]

173.99 [6.850] 180.34 [7.100] 81.28 [3.200] 86.995 [3.425] 81.28 [3.200] 86.995 [3.425]

209.55 [8.250] 215.9 [8.500] 81.28 [3.200] 86.995 [3.425] 27.94 [1.100] 35.56 [1.400] 81.28 [3.200] 86.995 [3.425]

224.79 [8.850] 231.14 [9.100] 48.26 [1.900] 56.515 [2.225] 48.26 [1.900] 55.88 [2.200] 48.26 [1.900] 55.88 [2.200] 48.26 [1.900] 56.515 [2.225]

E MAX

a

a’

b

b’

c

c’ d d’

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

2,000

TECHNIQUE:

19

1/1

Amphenol Socapex │ SIAL

SIAL >> SIGNAL VERSION (  ) LAYOUTS

The boards are shown from the connector side All contact locations are equidistant.

With Right Angle PC tail signal contacts for plug

p0 p0 p

R3 R2

R1

p

p/2

R3

d2

d1

d1

d2

d4

d1d1d1d1 d3

D

DAUGHTER BOARD OF SIGNAL YC CONTACT FOR PLUG Y(0). - 000

DAUGHTER BOARD OF FOR PLUG Y0. NX05

P P P

P P P

P P P

R1

P/2

P/2

P

R3 R2

R3 R2 With SMT signal contacts for plug

P P/2

R1

P/2

b

b p2

D d4' p1 p1 d3' d3' p1 p1 d3' d8

d4'

p1 p1

d3 d1

d2

d8

d9 d9

D

d1

d2

DAUGHTER BOARD OF HYBRID C FOR PLUG Y0. K(2)06-000

DAUGHTER BOARD OF HYBRID CONTACT FOR PLUG Y. K(2)03-000 D

DAUGHTER BOARD OF SIGNAL SMT TYPE CONTACT FOR PLUG U-000

p1 p1

p1 p1

R3

CONTACT -000

P

P/2 R1

p1 p1

R3

With Straight PC tail signal contacts for receptacle

' L

R1

d4'

d3' d3'

d3'

d4'

d3'

D d1

d2

P/2

P

R1

D

R3'

DAUGHTER BOARD OF HYBRID FOR PLUG Y0. K(1)06-000

DAUGHTER BOARD OF HYBRID CONTACT FOR PLUG Y. K(1)03-000

d5

A

Plan originel ECHELLE

2,500

ACT

d2

d1d1

d2

D

R1

R3'

MOTHER BOARD OF SIGNAL CONTACT FOR RECEPTACLE Y09 - 000

R1

R3

P P/2

L

d1 2 R2

d2

R 1

R 3

R 3 ’

p

p/2

p 0

p 2

d 1

d 2

d 8

d 9

a

b

h 1

h 2

+0.15 -0.1

Ø 0.6 MIN [.024]

Ø 3.3 [.130]

2.54 [.100]

1.27 [.050]

1.905 [.075]

0.85 [.033]

3.81 [.150]

4.445 [.175]

4.02 [.158]

3.39 [.133]

2 MAX [.079]

0.5 MAX [.020]

3.81 [.150]

3.81 [.150]

Ø 2.3

R3

+.006 -.004 ]

[.091

ACT

d2

d1

d5

D

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

20 MOTHER BOARD OF HYBRID CONTACT FOR RECEPTACLE Y09 NT05-002 2,500

TECHNIQUE:

3/3

Amphenol Socapex │ SIAL

TYPICAL ARRANGEMENTS SIAL>> COAXIAL VERSION (  )

18 signal contacts + 3 coax

58 signal contacts + 3 coax

FEMALE_58WAYS_3COAX

FEMALE_18WAYS_3COAX

a

a

b'

a'

b'

a'

D

D

FEMALE_98WAYS_3COAX

98 signal contacts + 3 coax

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

6,000

TECHNIQUE:

1/1

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

5,000

TECHNIQUE:

1/1

a

b'

a'

D

FEMALE_156WAYS_10COAX

5 coax + 156 signal contacts + 5 coax

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

4,000

TECHNIQUE:

1/1

b

a'

b'

c'

D

FEMALE_196WAYS_5COAX

196 signal contacts + 5 coax

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

3,500

TECHNIQUE:

b

c

1/1

a'

b'

c'

D

FEMALE_254WAYS_5COAX

254 signal contacts + 5 coax

c

b

a'

b'

c

D

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

3,500

TECHNIQUE:

1/1

18 + 3

58 + 3

98 + 3

5 + 156 +5

196 + 5

254 + 5

D

46.99 [1.850] 53.34 [2.100]

67.31 [2.650] 73.66 [2.900] 27.94 [1.100] 36.195 [1.425]

87.63 [3.450] 93.98 [3.700] 48.26 [1.900] 56.515 [2.225]

148.59 [5.850] 154.94 [6.100]

143.51 [5.650] 149.86 [5.900] 48.26 [1.900] 56.515 [2.225] 48.26 [1.900] 55.88 [2.200] 31.115 [1.225]

173.99 [6.850] 180.34 [7.100] 81.28 [3.200] 86.995 [3.425] 48.26 [1.900] 55.88 [2.200] 31.115 [1.225]

E MAX

a

7.62 [.340]

/

a’

15.875 [.625]

31.115 [1.225] 81.28 [3.200] 86.36 [3.400] 31.115 [1.225]

b

/

/

/

b’

31.115 [1.225]

31.115 [1.225]

31.115 [1.225]

c

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

2,500

TECHNIQUE:

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

1/1

21

R1

R3

R2

p0

p0/2

p0

P P/2

p0

P/2

P

R1

R3'

Amphenol Socapex │ SIAL

d4

d3 d3

d3 d1

d2

d1

D

d2

d1d1

d2

D

DAUGHTER BOARD OFHYBRID CONTACT FOR PLUG Y0. NX10-000

MOTHER BOARD OF SIGNAL CONTACT FOR RECEPTACLE Y09 - 000

SIAL >> SIZE 16 COAXIAL VERSION (  ) LAYOUTS

R1

R3

P P/2

L

R1

p0

P/2

P

p0 p0

p0/2

R2

R3

d2

d1

d5

The boards are shown from the connector side All contact locations are equidistant.

D

d4

d3 d1

d1 d3

d4

d1

d1

D

MOTHER BOARD OF HYBRID CONTACT FOR RECEPTACLE Y09 NT05-002

DAUGHTER BOARD OF HYBRID CONTACT FOR PLUG Y0. NX10-001

With Y0. male signal contacts and 5 coaxial contacts for plug

R1

R3'

L

P P/2

R2

R1

P

P/2 p0

p0 p0/2

R3

D d5 d1

d2

d2

d1 d3

d1

d4

D

MOTHER BOARD OF HYBRID CONTACT FOR RECEPTACLE Y09 KT03-000

DAUGHTER BOARD OF HYBRID CONTACT FOR PLUG Y0. NX05-002

With Y0. male signal contacts and 5 coaxial contacts for plug

A

Plan originel ECHELLE

DESSIN: le

R1

Amphenol Socapex

R3

R2

R3 R2 p0

p0 p0 p0/2 p0/2 p0

P P/2 R1 P P/2 p0

2,500

TECHNIQUE:

R1

p

p/2

P/2

P

R1

R3'

3

d4

d3 d3

d3 d1

d2

d4 d1

d2

d1

d1

d2

d1d1d1d1 d3 d1

d2

D

d2

d1d1

d2

D

D

D

DAUGHTER BOARD OF SIGNAL YC CONTACT FOR PLUG Y(0). - 000

DAUGHTER BOARD OF HYBRID CONTACT FOR PLUG Y0. NX05-000 DAUGHTER BOARD OFHYBRID CONTACT FOR PLUG Y0. NX10-000

MOTHER BOARD OF SIGNAL CONTACT FOR RECEPTACLE Y09 - 000

With Y0. male signal contacts and 10 coaxial contacts for plug

R1

R3

P P/2

L

P P P

R1

P P P R3

P P P R1 p0/2 p0

P

P/2 R2

R1

P/2

P/2

P

R1 P P/2

P/2

R3 R2

R3 R2

p0

p0

P/2

p0

P

p0 p0

p0/2

P

R2

R1

R3'

P/2

R3

d2

d1

d5

d4' p1 p1 d3' d3' p1 p1 d3' d1 d3 d3 d4 d1

d3 d1

d2

D

d2

d4'

p1 p1

d3 d1

d2

d1

d1

d4

d3 d1

d1 d3

d4

D

D

d2

d1d1

d2

D

D

D

MOTHER BOARD OF HYBRID CONTACT FOR RECEPTACLE Y09 NT05-002 MOTHER BOARD OF SIGNAL CONTACT FOR RECEPTACLE Y09 - 000

DAUGHTER BOARD OF HYBRID CONTACT FOR PLUG Y0. K(2)06-000

DAUGHTER BOARD OF HYBRID CONTACT FOR PLUG Y0. NX10-001 DAUGHTER BOARD OFHYBRID CONTACT FOR PLUG Y0. NX10-000

DAUGHTER BOARD OF HYBRID CONTACT FOR PLUG Y. K(2)03-000

With Y0. male signal contacts and 10 coaxial contacts for plug

R1

R3'

L

P P/2

R1

R3

P P/2

L

R2

p1 p1

p1 p1

P P

R3

R1

P/2

P

P/2 R1

p1 p1

R1

R3

P

P/2 p0

p0 p0/2

R1

R3

p0

P/2

p0 p0

p0/2

R2

R1

R3

R2

p0

p0/2

p0

P P/2

p0

P/2

P

R1

R3'

R3

R3'

P P/2

L

R1

b

b p2

D d5 d1 D d1

d2

d2

d5

d4'

d3' d3'

d3' d1

d2

d4'

d3'

D d1

d2

D

d1

d1

d4

d3 d1

d1 d1 d3

d4

d2

d1 d3

d4

d4

d3 d3

d3 d1

d2

d1

D D

d8

d9 d9

d8

d5

d1

d2

D

DAUGHTER BOARD OF HYBRID CONTACT FOR PLUG Y0. K(1)06-000 d1d1 d2

MOTHER BOARD OF HYBRID CONTACT FOR RECEPTACLE Y09 KT03-000 MOTHER BOARD OF HYBRID CONTACT FOR RECEPTACLE Y09 NT05-002

d2

DAUGHTER BOARD OF HYBRID CONTACT FOR PLUG Y. K(1)03-000

d6

D

D

d7

DAUGHTER BOARD OF HYBRID CONTACT FOR PLUG Y0. NX05-002 FOR PLUG Y0. NX10-001

DAUGHTER BOARD OFHYBRID CONTACT FOR PLUG Y0. NX10-000

D

A With Y09 female signal contacts and 5 coaxial contacts for receptacle

Plan originel ECHELLE MOTHER BOARD OF SIGNAL CONTACT FOR RECEPTACLE Y09 - 000 Amphenol Socapex DESSIN: le TECHNIQUE: 2,500

Plan originel ECHELLE DAUGHTER BOARD OF SIGNAL SMT TYPE CONTACT FOR PLUG U-000 L P P/2 R3'

R1

P P P/2 MOTHER BOARD OF HYBRID CONTACT FOR RECEPTACLE Y09 KT06-000 P/2 p0 R3 L '

A

DESSIN: le

R2

Amphenol Socapex

R1

p0 p0/2

2,500

TECHNIQUE:

R1

1/3

R3

R1

p0

P/2

P

p0 p0

p0/2

R1

R3'

R2

P P/2

L

R3

D d5 d1

d2

d2

d1 d3 d1

d5

d2

d1

d4

D

d5 d1

d1 d5

d4

d3 d1

d1 d3

d4

d1

d1

D

MOTHER BOARD OF HYBRID CONTACT FOR RECEPTACLE Y09 KT03-000

D

D

MOTHER BOARD OF HYBRID CONTACT FOR RECEPTACLE Y09 NT05-002

DAUGHTER BOARD OF HYBRID CONTACT FOR PLUG Y0. NX05-002 MOTHER BOARD OF HYBRID CONTACT FOR RECEPTACLE Y09 NT10-00.

With Y09 female signal contacts and 5 coaxial contacts for receptacle

DAUGHTER BOARD OF HYBRID CONTACT FOR PLUG Y0. NX10-001

A

Plan originel ECHELLE

DESSIN: le

Amphenol Socapex

R1

R3'

L

P P/2

2,500

TECHNIQUE:

L

R1

R3'

R2

R1

R3'

P P/2

L

R1

P

P/2 p0

p0 p0/2

R3

b

b p2

d8

d9 d9

d8

d5 d1

d1

d1

d2

D d5 d1 D d5 d6

d2

d1

d2

d1 d3

d1

d4

D

d7

D

D

MOTHER BOARD OF HYBRID CONTACT FOR RECEPTACLE Y09 KT03-000 MOTHER BOARD OF HYBRID CONTACT FOR RECEPTACLE Y09 NT05-000 With Y09 female signal contacts and 10 coaxial contacts for receptacle MOTHER BOARD OF HYBRID CONTACT FOR RECEPTACLE Y09 KT06-000

DAUGHTER BOARD OF SIGNAL SMT TYPE CONTACT FOR PLUG U-000

DAUGHTER BOARD OF HYBRID CONTACT FOR PLUG Y0. NX05-002

A

Plan originel ECHELLE

DESSIN: le

R1

R3'

A

Amphenol Socapex

Plan originel ECHELLE P P/2

DESSIN: le

L

Amphenol Socapex

2,500

TECHNIQUE:

2,500

TECHNIQUE:

3/

2/3

d5 d1

d1 d5

D

MOTHER BOARD OF HYBRID CONTACT FOR RECEPTACLE Y09 NT10-00.

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

L

R1

R3'

22

d5 d1

d1

d1

d2

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 38 Page 39 Page 40

Made with FlippingBook - Share PDF online