8.4 Che ck that the co mpression co uplings o f t he p ulse valves a re t ight .

8.5 Manually activate the reverse cle anin g valves (from t he Tur bo p ulse cle anin g co ntrol).

8.6 Che ck each v alve fo r leaks . NOTE : It is n orm al (and exp e cted) fo r the b leed air p o rt to release a b urs t of air at each p ulse.

8.7 Check the adequacy o f air s upply b y a ssurin g n o les s t han 35% d rop in p ressure d uring p ulse.

9. START UP

9.1 Apply co mpressed air t o t he man ifold .

9.2 Energize (push t he ST ART button ) for the main blower.

9.3 Energize the Turbo Digital Pulse Co ntro l ( reverse j e t pulse co ntrol), if so equipped.

9.4 Energize othe r auxiliary e quipment, as re quired.

9.5 COMMENT S RE GARDING FIL TE R DIF FERENT IAL PRESSURE DURIN G O PERATION:

9.5.1 Dependin g o n operatin g co nditions, reachin g equ ilibrium for filte r differentia l p ressure may vary from a f ew h ours t o several weeks . Low d us t loadin g w ill n ormally d evelop 1-2”w.g. , norm al loading typically generat es 2-5”w.g., and h igh loadin g varies fro m 5 - 10”w.g. 9.5.2 Low d us t loadin g t ypically sho ws a steady lev e l o f d ifferentia l p ressure with v ery lit tl e fluctuations o nce eq uilibrium is r eached . By contrast, h eavy lo adin g ca n p roduce significan t “Ups a nd Downs” in o peratin g d ifferent ial pressure . 9.5.3 If y ou r un it is eq uipped with t he p rogrammable p ulse contro l, then it is u sually n ecessary t o gradually (ove r a period o f w ee ks or months) raise t he high and lo w set points t o r efle ct the n orm al buildup o n t he fil ters.

10. SHUTDOWN

10.1 De-energize (p ush t he STOP button ) the b lowe r motor. The digita l re verse p ulse cl eanin g s ystems are equipped with an “Off L ine Cl eaning” fe ature which a ctivates t he reverse j e t pulse cleaning . This elemen t will clean the filter ca rtridges while t he un it is o ff lin e, for a prese t numbe r of p ulses . Once t he cl eanin g cy cle is co mple te t he collecto r is r eady t o b e en ergized when n eeded.

10.2 Secure p owe r to t he d igita l rev erse pulse co ntrol.

10.3 Secure p owe r to t he ligh ts, a nd o the r auxiliary equipment.

CAUTION: Off line cleaning can cause pressure waves to feed back through system. Precautions may be necessary to prevent dusting.