Ariston Solar Water Heaters

SOLAR HEATING SYSTEMS AND CYLINDERS

HOT WATER I HEATING I RENEWABLE I AIR CONDITIONING

2 /

THE JOURNEY OF CHALLENGE

FOUNDATION / Aristide Merloni founds “Industrie Merloni” company in the Marche Region of Italy, and starts the production of weighing scales.

1930s

WATER HEATING / Our brand is launched and the production of electric water heaters begins.

1960s

HEATING / We consolidate our market leadership in water heating and the production of boilers begins.

1980s

GLOBAL EXPANSION / With the launch in China and Russia, we start our evolution into a global brand.

1990s

RENEWABLE / We successfully develop and launch our new model in heat pump, which marks our development into innovative and sustainable heating technology.

2000s

ADVERTISING AND BRAND POSITIONING / Ariston launches its first global advertising campaign, defining a new visual identity.

2010s

COMFORT CHALLENGE / Ariston embarks on a unique mission: that of bringing thermal comfort everywhere, even where it seems impossible.

2018s

/ 3

WHAT DOES COMFORT MEAN TO YOU?

4 /

ARISTON TAKES UP THE CHALLENGE OF BRINGING US THE COMFORT WE ALL DESIRE.

In this fast-growing world, we all desire a place to belong. A place to feel settled and comfortable , where each of us, at some point in our lives, can make new decisions to move on. We want to keep this feeling along our lives, while we set up our first home, or when we nest and start a family, growing and aging together. In any case, we always hope for our beloved ones to stay nice and cosy, providing them with the warmth they deserve.

We all have our own idea of comfort : this might come in dierent forms, but it is what we all yearn for.

NO MATTER WHAT’S YOUR IDEA OF COMFORT. OUR CHALLENGE IS TO GIVE EVERYONE THE COMFORT THEY NEED. EVEN WHERE IT SEEMS HARD OR IMPOSSIBLE TO FIND. Ariston always takes action to introduce new ways of bringing comfort to every corner of the world : finding where comfort hasn’t been fully reached and innovating methods for adjusting the concept of comfort to people’s lives.

/ 5

ERP ARE YOU UPTODATE WITH THE NEW REGULATIONS?

Since 26 September 2015, the new European Union regulations define minimum eciency and energy labelling requirements for boilers, heat pumps, micro-cogeneration, water heaters and hot water tanks.

With eect from 26 September 2018, limits will be introduced regarding emissions of NOx , which add to the eciency limits already in force. The NOx limits will only apply to products placed on the market starting from 26 September 2018. Products purchased before that date and already in retail outlets or distribution warehouses can continue to be sold and installed, even though they do not comply with the new requirements.

26.09.2015

2017

26.09.2018

2019

A+ introduced for domestic hot water production

A+++ introduced for space heating

A++ (space heating) / A (water heating) Compulsory labelling on space heating and water heating products (energy class) Minimum performance requirements for space heating and domestic hot water production

A

B

C D E F G

New limits for NOx emissions < 56 mg/kWh (for gas fuels) DISCOVER THE LOW NO x -EMISSION RANGE INSIDE THE CATALOGUE

6 /

PRODUCT LABEL There are dierent labels, depending on the type of product and service guaranteed. The eciency classes A, A+ and A++ indicate the products with higher performance. There are two different classifications for the heating and water production services; for products which can provide both services, labels must show both the classifications. In addition to the energy class, the labels display information to help consumers choosing the most ecient prodcts with less environmental impact (power consumption in dierent weather areas noise, etc ...).

Manufacturer

GENUS PREMIUM EVO 24 EU 3300704

Model Heating Sanitary function and level of usage

XL

A ++

A

A

A +

B

A

A

C

B

Energy class

D

C

D

E

E

F

F

G

G

Nomnal thermal power

Sonor power

22 kW

48 dB

811/2013

2015

Energy label of a boiler

SYSTEM LABEL All devices for which it is proposed (or expected) a combination with predefined devices, must have a second label, in addition to the product label and technical documentation, advertising and promotional materials showing its performance. Who sells these systems will be responsible for define the achieved performance (through an automatic algorithm) and inform his client. Go on ariston.com and use our online configurator to achieve, download and print the system label. ariston.com

Manufacturer

HEATING SYSTEM WITH GENUS PREMIUM EVO EU, THREE-ZONE-

THERMOREGULATION AND SOLAR INTEGRATION FOR DOMESTIC

HOT WATER PRODUCTION

Model

Energy classes (heating and hot water) of the product Energy classes (heating and hot water) of the system

A

A +++

A ++

A

A +

XL

A +

A

B

C

+

D

E

Solar collectors

F

G

+

Hot water tank

XL

A +++

A ++

+

A +

Device for temperature control

A +

A

B

C

D

+

Additional heating appliance

E

F

G

2015

811/2013

Energy label of a combi boiler

/ 7

SOLAR HEATING SYSTEMS

KAIROS THERMO DR-2

KAIROS THERMO CF-2

8 /

KAIROS FAST CD1 CF-1 CD2 CF-1

KAIROS THERMO HF

/ 9

ARISTON CARES!

Energy eciency is becoming a more and more common word when talking about domestic hot water production and delivery. The growing concern for the future of the environment we are living in, and the desire to leave a green and healthy world to future generations is creating a shift in the demand from traditional technology towards high-eciency and renewable products. Modern technologies like solar systems and air to water heat pumps perfectly serve the scope. They use a clean and renewable source, either sun or air, to heat the water thus giving you maximum comfort while reducing polluting emissions and protecting the environment.

Ariston Thermo Group, a leading brand in thermal comfort, has been proposing alternative energy-ecient solutions worldwide since many years. With its wide range of solar systems (both natural and forced circulation) and air-to-water heat pumps (both monoblock and split versions) is capable of oering in every situation the right solution to give its end-user hot water with an environmentally friendly attitude. Ariston Thermo Group has committed itself to a long-term challenge: reach 80% of its sold products only on high-energy eciency and renewable products by 2020 in order to bring a tangible change in the world we are living in. DO YOU WANT TO TAKE PART TO THIS CHANGE?

10 /

ARISTON QUALITY: SIMPLY “MADE IN ITALY”

INTERNATIONAL QUALITY CERTIFICATION All Ariston factories are certified by CSQ, a member of the International Certification Network IQNet. As a result, all Ariston products are manufactured in compliance with the highest standards, guaranteeing reliability and high-quality. Every year all the plants are involved in a competition aimed to improve the quality level of the production. 3 MILESTONES OF QUALITY Customer satisfaction is Ariston’s main concern and this is why quality is constantly monitored at every level through: • Incoming control of the raw materials and components • Process Control aiming to intercept the potential defects in earlier stages of the manufacturing process • Product Testing of 100% of the production in the line to assure the correct functioning of the product

ITALIAN TECHNOLOGY & DESIGN Driven by innovation but still linked to its roots.

This is the perfect mix that represent Ariston attitude and that pushes the members of the R&D department to develop more efficient, eco-friendly and reliable products always with the quality and design typical of the Italian manufacturing tradition.

/ 11

ARISTON SOLAR SYSTEMS: 30 YEARS OF EXPERIENCE AT YOUR SERVICE

WHEN YOU INSTALL AN ARISTON SOLAR SYSTEM AT YOUR HOME, YOU ARE NOT SIMPLY INSTALLING A PRODUCT; YOU ARE BRINGING AT YOUR HOME 30 YEARS OF EXPERIENCE, SYSTEM DESIGN, PRODUCTS TEST AND EVOLUTION. 1982 Ariston opens the first plant for the production of solar collectors to contrast rising price of oil in Europe, that at that time was incentivizing green technologies. In the first year the record production of 44.000 m2 was reached. Ariston Thermo immediately became a leader in this sector. The production was meant just for Italy at that time and we kept manufacturing collectors in Cerreto (Italy) till 2001.

1983 The first Ariston solar collector is o€cially certified by ENEL, national authority of energy in Italy. Ariston solar collectors are used to realize one full wall of a skyscraper in Milan.

2002 Acquisition of Elco company, leader in north west Europe in heating and with a long tradition in solar systems. All the products in the actual range are tested separately by Ariston (Italy) and Elco (Germany) to ensure covering all possible working conditions.

2004 Opening of a new solar plant in India for Indian Market only. Starting the production of vacuum tube in China. Tubes and manifold technology are patented by Ariston.

2007 Serra De’ Conti plant (Italy) was opened and became the center of the R&D dept for all the plants. Serra De’ Conti is one of the most technologically advanced plant in Europe.

2012 “Sun&wind Energy” magazine, places Ariston as first manufacturer of solar collectors in Italy

12 /

OBJECT: test on flat collectors according to 80/PDB/001 specification. Collector model RAV 1,8 4L/E3 With the following letter we are pleased to inform you that your collector model RAV 1.8 4L/E3, whose characteristics are those certified in the technical drawing sent to PHOEBUS and shown in the attached, are compliant to the 80/PDB/001 requirements and therefore, as soon as ENEL will promote solar water heaters to its end-users, your collector can be part of the oŽer as per the conditions agreed. “ ”

OUR FIRST SOLAR COLLECTOR WAS CERTIFIED IN 1983 BY THE ITALIAN NATIONAL BODY OF ENERGY.

/ 13

ARISTON SOLAR THERMAL: QUALITY GUARANTEED

CERTIFIED ENERGY EFFICIENCY The Ariston collectors have maximum e ciency levels and respond to the EN 12975 Standard. All of this has been checked by strict tests performed at ac- credited research centres. The new products have acquired the Solar Keymark. Ariston also distinguishes itself for the attention reserved for its customers in the after-sales period. The five year warranty covers the collector and the cylinder, while the electronic control unit, the pump unit and the accessory kits are guaranteed for two years. LONGER LASTING AND SAFER The special highly transparent toughened glass of the Ariston collectors reflects the incident solar rays to a minimum, thus loosing little energy. The solar energy absorbed is also withheld thanks to its prismatic surface, which creates a “greenhouse e„ect” inside the collector. The maximum e ciency is accompanied by the safety of toughened glass, tested against hail.

ANTI-REFLECTIVE AND HAIL-PROOF

14 /

TYPE OF SOLAR SYSTEM

As for heat systems, the heat is transferred by means of a “heat carrying fluid” that runs between the solar panel and the cylinder. The fluid can run spontaneously or using a pump. On the basis of which the two types of solar systems are distinguished: natural or forced circulation.

THE SOLUTION TO ALL NEEDS

NATURAL CIRCULATION SIMPLE RELIABLE ECONOMIC REDUCED MAINTENANCE

FORCED CIRCULATION

EFFICIENT FLEXIBLE ARCHITECTONIC INTEGRATION IN SYMBIOSIS WITH THE BOILER

/ 15

COMPLETE SYSTEMS

KAIROS THERMO DR-2

KAIROS THERMO CF-2

100-1

150-1

200-1

250-2 150-1

200-1

200-2 300-2

natural

natural

TYPE OF CIRCULATION

yes

yes

ROOF INSTALLATION

GROUND AND FLAT ROOF INSTALLATION

yes

yes

direct

indirect

TYPE OF SYSTEM

ELECTRO SOLAR VERSION AVAILABLE

yes

yes

1

1

1

2

1

1

2

2

NUMBER OF COLLECTORS

1,92

1,96

GROSS AREA (m 2 )

not necessary

not necessary

EXPANSION VASE

not necessary

not necessary

SENSYS

-

-

TANK ENERGY CLASS

34

44

51

61

50

60

60

85

TANK EMPTY WEIGHT (kg)

30,6

27

COLLECTOR WEIGHT (kg)

yes (only collector),

yes

SOLAR KEYMARK

18

20

PAGE

16 /

KAIROS THERMO HF

KAIROS FAST CD1 CF-1

KAIROS FAST CD2 CF-1

150-1

200-1

200-2

300-2

150-1

200-2

300-2

200-2

300-2

natural

forced

forced

yes

yes

yes

yes

yes

yes

indirect

indirect

indirect

yes

-

-

1

1

2

2

1

2

2

2

2

2,2

2,01

2,01

not necessary

included, 16 l

included, 16 l

not necessary

included

included

-

B

C

C

C

C

50

60

60

85

82

110

119

114

131

35

29,5

29,5

yes

yes (only collectors)

yes (only collectors)

22

26

26

/ 17

KAIROS THERMO DR-2 NEW

Direct flat solar water heater

ADVANCED PERFORMANCE / More hot water thanks to direct solar water heating technology / Increased tank insulation to guarantee long-lasting hot water storage / Stable water temperature during withdrawal thanks to optimized tank stratification / Tailored solar range for sun belt countries EVERLASTING QUALITY / Each component of the solar water heater (collector, tank and installation kit) is 100% made to last / Total safety guaranteed by tank safety valve and thermostat*, by collector tempered glass and installation kit robustness / Every single component and the complete solar water heater are carefully and strictly tested on quality, efficiency and performances ITALIAN STYLE / Easy installation thanks to “insert and click” connections between collector and hydraulic kit / Wide range of mounting kits to fit each kind of installation need / Designed in Italy

*only for electro solar version

TECHNICAL DATA

KAIROS DR2.0-2 B/N

PerformanceTank optimization

Weight

kg

30,6

Dimensions

mm bar

1985x967 x75

Max operating pressure

8

E›ciency

%

49/46

Optimized hot water storage and tank insulation:

Absorber material Absorber coating Absorber thickness

Aliminum

Selective blue or black

/ Thanks to optimized water stratification Thermo DR-2 reduces the mixing of hot and cold water in the tank. In addition, this is boosted by the new position of the hot water outlet (on the top of the tank) granting stable water temperature during the withdrawal. / Thanks to the increased tank insulation (+20% vs old model) and an optimal polyurethane quality the solar water heater is able to maintain the water hot all night long

mm

0,4

Collector fluid capacity instead of Sensor fluid capacity

1,8

l

95/90

Absorption

%

Emission

5/20

%

Gross area

m2 m2 m2

1,92 1,77 1,73

Aperture area Absorber area

х 0

0,74/0,683 4,045/4,248 0,014/0,015

K1

W/(m2K) W/(m2K)

K2

Absorber tubing material Stagnation temperature

Copper 190/180 0,89/0,9

°C

IAM (50°)

TECHNICAL FEATURES

DR 100-1 DR 150-1 DR 200-1 DR 250-2

Ground or flat / pitched roof

Ground or flat / pitched / IBR roof

Installation

Pre-painted steel (standard version) Steel with Zn external coating (electro solar version) Titanium enameled with 3+1 lateral connection

External cover material

Optimized hot water outlet

Optimized cold water inlet

Inner tank material

cold water

hot water

Diameter of external connections

¾’’ F

Nember of collectors Insulation thickness

1

1

1

2

mm

55

55

48

48

SV

Max working temperature for main tank

°C

105

solar tank

Optional (standard version) Included (electro solar version)

Back-up heating element (2 kW)

Capacity of storage tank for domestic hot water

l

100

150

200

250

Cylinder empty weight Dimensions (LxDxH)

kg

34

44

51

61

mm

See drawing

KAIROS DR

100-1

150-1

200-1

250-2

TR (ground) TT (roof) TR (ground) TT (roof) N (black) B (blue)

3022303 3022304 3022312 3022313

- 3022307 - 3022315

Standard version N (black) absorber

solar collector

- -

- 3022306 - 3022314

- -

Standard version B (blue) absorber

- 3022296 3022297 3022299

Electro-solar version (TR)

-

- 3022298

-

Optional 2kW heating element (for standard version)

3687025 3687025 3687025 3687025

*Absorber certified

18 /

100-1 / 150-1 / 200-1 / 250-2

*

TECHNICAL DRAWING

32

1338

64

2506

144

1048

41

150-1

150-1

34

1376

58

2538

165

1048

41

200-1

200-1

250

1659

266

2530

75

2010

41

250-2

250-2

* Solar keymark on collector

/ 19

KAIROS THERMO CF-2

Indirect flat solar water heater

ADVANCED PERFORMANCE / Optimal stratification process to achieve higher performances and a faster heating / More hot water thanks new tubes position for 300-2 model EVERLASTING QUALITY / Each component of solar water heater (collector, tank and installation kit) is 100% made to last / Solar Keymarkcertification / Total safety guaranteed by solar circuit safety valve and thermostat*, by collector tempered glass and by installation kit robustness / Every single component and the complete solar water heater are carefully and strictly tested on quality, efficiency and performances ITALIAN STYLE / Easy installation thanks to “insert and click” connections between collector and hydraulic kit / New funnel for an easy filling of solar circuit / Wide range of mounting kits to fit each kind of installation / Designed & produced in Italy

NEW

*only for electro solar version

TECHNICAL DATA

KAIROS CF 2.0-2

Italian Style

Empty Weight

kg

27

Dimensions LxHxD

mm bar

1990x985x78

Max operating pressure

6

Easy installation:

Ešciency

%

72%

Collector fluid capacity instead of Sensor fluid capacity

l

1

Absorption

% %

95

/ Hydraulic Kit and collector are connected in two simple steps: Insert the hydraulic pipe in the manifold thanks to double O-ring Fix them with a metal clip / No tools are required, thus reducing the installation time by 25%*

Emission

5

Gross area

m 2 m 2 m 2

1,96 1,77 1,73

Aperture area instead of input area

Absorber area

Absorber material Absorber coating Absorber thickness

Aluminum

Blue Selective

mm

0,4

х 0

0,786

K1

W/(m2K) W/(m2K)

4,22

K2

0,0084 Copper

One mounting kit for each installation: / Ground/flatroof / Pitchedroof

Absorber tubing material Stagnation temperature

°C

210

TECHNICAL FEATURES

CF 150-1 CF 200-1 CF 200-2 CF 300-2

Installation

Ground or flat/pitched roof Steel with Zn external coating

Italian care for details: / Designed and produced in Italy

External cover material

Inner tank material

Titanium enameled

/ Care for details in shape and materials / Thermo CF-2 can be integrated beautifully into every type ofbuilding or house

Diameter of external connections

¾’’ M

Nember of collectors

1

1

2

2

Max pressure for maintank

bar mm

8

Insulation thickness

40

Max working temperature for main tank

°C

105

Optional (standard version) Included (electro solar version)

Back-up heating element (2 kW)

Aperture area Absorber area

m 2 m 2

1,77 1,73 153

1,77 1,73 202

3,54 3,46 202

3,54 3,46 270

Capacity of storage tank for domestic hot water

l l

Fluid capacity

1

1

1

1

Cylinder empty weight Dimensions (LxDxH) Cylinder empty weight

kg

50

60

60

85

mm

See drawing

kg

50

60

60

85

KAIROS CF

CF 150-1 CF 200-1 CF 200-2 CF 300-2

TR (ground) TT (roof) TR (ground)

3022280 3022281 3022282 3022283 3022288 3022289 3022290 3022291 3022272 3022273 3022274 3022275

Standard version

Electrical version

*Based on internal measurement

20 /

150-1 / 200-1 / 200-2 / 300-2

TECHNICAL DRAWING

1195

2519

23

1048

125

150-1

150-1

1481

340

354

1481

2511

75

2010

22

167

267

1048

200-2

200-1

200-2

33

1949

71

2511

22

2010

22

300-2

300-2

/ 21

KAIROS THERMO HF

PERFORMANCES / Optimized heat exchanger that allows a very quick production of domestic hot water; / The blue selective surface treatment forgives very high performances with the 95% absorbtion and only 5% reflection; DESIGN AND TECHNOLOGY / Accurate study of the lines, and of the external shape; / The new o-ring connection allows a very quick installation, even eliminating the risk to damage the hydraulic connection kit; QUALITY / The special tempered glass with low content iron assures very high protection against the hail, and against the collector’s loading; / Solar key mark and the test report according EN 12975-2. Natural circulation solar system for the production of domestic hot water

TECHNICAL DATA

HF 150/1 TR HF 150/1 TT HF 200/1 TR HF 200/1 TT HF 200/2 TR HF 200/2 TT HF 300/2 TR HF 300/2 TT

Solar collectors Installation

Ground or flat roof

Sloped roof

Ground or flat roof

Sloped roof

Ground or flat roof

Sloped roof

Ground or flat roof

Sloped roof

2.2

2.2

2.2

2.2

4.4

4.4

4.4

4.4

Collector gross surface Collector aperture surface

m 2 m 2 kg

2.01 135

2.01

2.01 153

2.01

4.02 200

4.02

4.02

4.02

Empty mass

133

151

190

231

218

Solar circuit capacity

l

6

6

6

6

8

8

11

11

Tank module Domestic hot water storage tank capacity

l

153

153

202

202

202

202

270

270

DHW circuit max. pressure

bar bar

8

8

8

8

8

8

8

8

Solar circuit safety valve calibration

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

Heat losses

kWh/24h

2.39

2.39

2.67

2.67

2.67

2.67

2.81

2.81

CODE (with antifreeze liquid)

3023535 3023536 3023537

3023538 3023505 3023506 3023539 3023540

CODE (without antifreeze liquid)

3023551

3023552 3023553 3023554

3023511

3023512 3023555 3023556

CODE (with 2 kW electrical heating element)

3022175

3022174

3022177

3022176

3022179

3022178

3022181

3022180

INTEGRATION SYSTEM

Description

Code

• • •

ENAMELLED ELECTRIC KIT 2 KW FOR 150-200-300 LT

3024272

ELECTRIC KIT 1,5 KW FOR 150-200-300 LT

107069

• • •

THERMOSTATIC MIXER

3024085

MOTORIZED THREE-WAY VALVE

3087085

DIGITAL THERMOSTAT

800232

INTEGRATED THERMOSTATIC MANUAL MIXING VALVE

3318379

HIGH FLOW RATE THERMOSTATIC MIXING VALVE

3318419

• • •

BUILT IN SOLAR KIT*

3318408

MOTORIZED BUILT-IN SOLAR KIT*

3318484

INTEGRATED SOLAR PROBE

3318317

A

B

C

*It is required the code 3318401 antifreeze kit (protection down -20 °c)

22 /

150 / 200 / 300

LIST OF COMPONENTS

Description

Code

1 1 1 1

1 1

1

1

KAIROS THERMO HF 150-1 TR ES

3023551

1

1

KAIROS THERMO HF 150-1 TT ES 3023552

1 1 1 1

1

1

KAIROS THERMO HF 200-1 TR ES 3023553

1

1

KAIROS THERMO HF 200-1 TT ES 3023554

2 2 2 2

1

1

KAIROS THERMO HF 200-2 TR ES 3023511

1

1

KAIROS THERMO HF 200-2 TT ES 3023512

1 1

1

1

KAIROS THERMO HF 300-2 TR ES 3023555

1

1

KAIROS THERMO HF 300-2 TT ES 3023556

1 1 1 1

1 1

1

1

KAIROS THERMO HF-E 2KW 150-1 TR 3022175

1

1

KAIROS THERMO HF-E 2KW 150-1 TT 3022174

1 1 1 1

1

1

KAIROS THERMO HF-E 2KW 200-1 TR 3022177

1

1

KAIROS THERMO HF-E 2KW 200-1 TT 3022176

2 2 2 2

1

1

KAIROS THERMO HF-E 2KW 200-2 TR 3022179

1

1

KAIROS THERMO HF-E 2KW 200-2 TT 3022178

1 1

1

1

KAIROS THERMO HF-E 2KW 300-2 TR 3022181

1

1

KAIROS THERMO HF-E 2KW 300-2 TT 3022180

/ 23

KAIROS THERMO HF

1518 (200 liters) 1194 (150 liters)

74,5

1522

89

Ø 536

74,5

153

800

126

2132 1995 930

1354

These drawings refer to150/1 and 200/1 models

These drawings refer to200/2 and 300/2 models

4

5

2

1

3

6

1 - Low dispersion polyurthean insulation free of CFC & HCFC 2 - Steel tank with exclusive titanium-based enamel treatment 3 - Annular heat exchanger 4 - 1,5 solar safety valve 5 - Extrenal tank in prepainted zinc-steel 6 - Cold water distrubution lance 7 - New o-ring connection

7

24 /

MAIN SYSTEM LAYOUTS

L

N

LAYOUT A

LAYOUT B

S

SE

BUS

LAYOUT C

Sacs

/ 25

KAIROS FAST

Forced circulation solar system with integrated single/double coil tank for the production of domestic hot water

PERFORMANCES / The selective aluminium absorber forgives very high efficiency, and reduced reflection; / The ultrasonic welding technology, on the collector, ensures very good performances for home applications; DESIGN AND TECHNOLOGY / The Sensys, the system interface included in the product, allows an easy navigation and a full control of all the working parameters, displaying the solar fraction, the storage of how water and the energy saving; / The preassembled storage offers the best enjoyble design of its category, thanks to the accurate study of the lines, and of the external shape; QUALITY / The collector’s solar key mark certifies the compliance with the international standard; / The protech anode guarantees anti-corrosion protection of the internal tank;

KAIROS FAST CD1 150-1

KAIROS FAST CD1 200-2

KAIROS FAST CD1 300-2

KAIROS FAST CD2 200-2

KAIROS FAST CD2 300-2

TECHNICAL DATA

1-KAIROS CF 2.0-1

2-KAIROS CF 2.0-1

2-KAIROS CF 2.0-1 2 - KAIROS CF 2.0 -1 2 - KAIROS CF 2.0 -1

SOLAR COLLECTORS

Collectors gross surface

m 2

2,01

4,02

4,02

4.02

4.02

Collectors aperture surface

m 2

1,74

3,48

3,48

3.48

3.48

STORAGE TANK MODULE Dimensions (L x H x P)

mm

697 x 965 x 889 697 x 1260 x 889 697 x 1782 x 889 697 x 1260 x 889 697 x 1782 x 889

Domestic hot water storage tank capacity

l

142

198

298

192

292

Heat loss

kWh/24h

1,1

1,49

2,28

1.49

2.28

DHW circuit minimum pressure

bar

7

7

7

7

7

DHW circuit max. pressure

mca

4,5

4,5

4,5

4,5

4,5

Solar expansion vessel capacity

l

16

16

16

16

16

Solar circuit safety valve calibration

bar

6

6

6

6

6

KAIROS FAST

CD1 150-1

CD1 200-2

CD1 300-2

CD2 200-2

CD2 300-2

Energy class

B

C

C

C

C

TR

3023637

3023639

3023645

3023641

3023645

TT

3023638

3023640

3023646

3023642

3023646

ACCESSORIES

CODE

SOLAR/DHW ADDITIONAL EXPANSION VESSEL ( 16L ) FOR MACC

3024183

26 /

CD1 150 / 200 / 300 - CD2 200 / 300

LIST OF COMPONENTS KAIROS FAST

Description

KAIROS FAST CD1 150-1 TR

1

1

1

2

1

1

1

KAIROS FAST CD1 150-1 TT

1

1

1

1

1

1

KAIROS FAST CD1 200-2 TR

1

2

2

2

1

1

1

1

KAIROS FAST CD1 200-2 TT

1

2

1

1

1

1

1

KAIROS FAST CD2 200-2 TR

1

2

2

2

1

1

1

1

KAIROS FAST CD2 200-2 TT

1

2

1

1

1

1

1

KAIROS FAST CD1 300-2 TR

1

2

2

2

1

1

1

1

KAIROS FAST CD1 300-2 TT

1

2

1

1

1

1

1

KAIROS FAST CD2 300-2 TR

1

2

2

2

1

1

1

1

KAIROS FAST CD2 300-2 TT

1

2

1

1

1

1

1

* DOCUMENTATION MACC (IT-EN) Code 3105018; DOCUMENTATION MACC (HU-PL-RO-CZ-RU-UA) Code 3105021; DOCUMENTATION MACC (TK-RU-GR-HR-SRB-UA) Code 3105022

/ 27

KAIROS FAST

CD1

889

645

996

628

383

1004

78

OVERALL DIMENSIONS

CD1 150-1 CD1 200-2 CD1 300-2

233

251

A

mm

965

1260

1782

645

CD2

889

645

996

1004

78

628

383

OVERALL DIMENSIONS

CD2 200-2 CD2 300-2

A B C

mm mm mm

1260 649 808

1782 1170 1330

233

251

645

28 /

MAIN LAYOUTS

A

B

/ 29

KAIROS MACC

Single/double coil pre-assembled tank module for the production of domestic hot water PERFORMANCES / The storage’s polyurethane insulation free of CFC & HCFC allows maximum protection against heat losses; / The storage can disperse up to 1,5 kWh/24 h (150 lt): one of the lowest value of its category; / The arrangement for an additional expansion vessel makes the product suitable for big solar systems; / The accurate design of the heat exchange surface can provide a big amount of hot water; DESIGN AND TECHNOLOGY / The motorized mixing valve gives you the possibility to set the desired temperature; / The preassembled storage offers the best enjoyble design of its category, thanks to the accurate study of the lines, and of the external shape; QUALITY / The air purge valve protects from air accumulation; / The preassembled hydraulic safety group protects the storage from high pressure working conditions;

TECHNICAL DATA

CD1 150

CD1 200

CD1 300

CD2 200

CD2 300

Domestic hot water storage tank capacity

l

142

198

298

192

292

DHW circuit max. pressure

bar

7

7

7

7

7

0.85

0.85

0.85

0.85

0.85

Lower coil surface

m 2

0.8

0.8

Upper coil surface

m 2

Max operating temperature

°C

85

85

85

85

85

m. H 2 O

4.5

4.5

4.5

4.5

4.5

Max solar pump head

Solar expansion vessel capacity

l

16

16

16

16

16

Solar circuit capacity

l

6

6

6

6

6

Upper exchanger capacity

l

4.5

4.5

Solar circuit safety valve calibration

bar

6

6

6

6

6

Tank's thermal dispersions

kWh/24h

1.1

1.49

2.28

1.49

2.28

Empty mass

kg

82

106

119

110

131

KAIROS MACC

CD1 150

CD1 200

CD1 300

CD2 200

CD2 300

Energy class

B

C

C

C

C

(IT-EN)

3023271

3023272

3023273

3023274

3023275

(HU-PL-RO-CZ)

3023303

3023304

3023305

3023306

3023307

(TK-RU-GR-HR-SRB-UA)

3023308

3023309

3023310

3023311

3023312

ACCESSORIES

CODE

SOLAR/DHW ADDITIONAL EXPANSION VESSEL ( 16L ) FOR MACC

3024183

30 /

CD1 150 / 200 / 300 - CD2 200 / 300

1 Sensys user interface 2 Solar safety valve 3 Pressure sensor 4 Motorised thermostat - controlled mixing valve 5 Hydraulic safety assembly with siphon 6 Connection for additional solar vessel / domestic water expansion vessel 7 Solar fluid collection tank with indicator

1

8 Flow meter 9 Solar pump 10 16 litre solar expansion vessel 11 Pressure gauge 12 Deareator

12

2

10

11

3

9

4

8

5

6

7

LIST OF COMPONENTS KAIROS MACC

Description

Code

KAIROS MACC CD1 150 (IT-EN)

3023271

1

1

KAIROS MACC CD1 150 (PL-CZ-HU-RO)

3023303

1

1

KAIROS MACC CD1 150 (TK-HR-SRB-GR-RU-UA)

3023308

1

1

KAIROS MACC CD1 200 (IT-EN)

3023272

1

1

KAIROS MACC CD1 200 (PL-CZ-HU-RO)

3023304

1

1

KAIROS MACC CD1 200 (TK-HR-SRB-GR-RU-UA)

3023309

1

1

KAIROS MACC CD1 300 (IT-EN)

3023273

1

1

KAIROS MACC CD1 300 (PL-CZ-HU-RO)

3023305

1

1

KAIROS MACC CD1 300 (TK-HR-SRB-GR-RU-UA)

3023310

1

1

KAIROS MACC CD2 200 (IT-EN)

3023274

1

1

KAIROS MACC CD2 200 (PL-CZ-HU-RO)

3023306

1

1

KAIROS MACC CD2 200 (TK-HR-SRB-GR-RU-UA)

3023311

1

1

KAIROS MACC CD2 300 (IT-EN)

3023275

1

1

KAIROS MACC CD2 300 (PL-CZ-HU-RO)

3023307

1

1

KAIROS MACC CD2 300 (TK-HR-SRB-GR-RU-UA)

3023312

1

1

* MACC Documentation (IT-EN) Code 3105018; MACC Documentation (HU-PL-RO-CZ-RU-UA) Code 3105021; MACC Documentation (TK-RU-GR-HR-SRB-UA) Code 3105022;

/ 31

KAIROS MACC

CD1

889

645

628

383

8 CD1 150 CD1 200 CD1 300

OVERALL DIMENSIONS

233

251

A

mm

965

1260

1782

645

CD2

889

645

628

383

110 CD2 200 131 CD2 300

OVERALL DIMENSIONS

A

mm

1260

1782

233

251

B

mm

649

1170

645

C

mm

808

1330

32 /

MAIN LAYOUTS

A

B

/ 33

KAIROS COMBI

Integrated tank for the solar heating integration and for the production of domestic hot water

PERFORMANCES / The soft 100 mm insualation allows maximum protection against heat losses; / The high residual head (6,5 m) of the pump gruop assures the proper working of big systems; DESIGN AND TECHNOLOGY / Kairos Combi includes all the accessories needed for a complete installation: the digit pump group, the digital manometer, the digital flow meter... / The Sensys, the system interface included in the product, allows an easy navigation and a full control of all the working parameters, displaying the solar fraction, the storage of how water and the energy saving; QUALITY / The air purge valve protects from air accumulation inside the system; / The preassembled hydraulic safety group protects the storage from high pressure working conditions;

TECHNICAL DATA

CK1 400

CK1 600

CK1 800

CK1 1000

Domestc hot water storage tank capacity

l

400

600

800 2.8 17.5

1000

Coil surface

1.5

2.1 13

3.4

Solar coil capacity

l

9.3

21

Max operating tank pressure Max operating temperature

bar

3

3

3

3

°C kg

95 92

95 113

95

95 176

Empty mass

155

DHW PRODUCTION MODULE (WITH DHW RECIRCULATION ACCESSORY)

FRESH WATER STATION

Temperature range Minimum flow rate

°C

36 ÷ 65

l/min l/min

2.5

Sanitary flow rate measurer Max primary circuit pressure Max DHW circuit pressure

2.5 ÷ 32

bar bar

3 6

Max DHW/primary circuit temperature

°C

85

Electrical supply/Frequency

V/Hz

230 / 50 40 (100)

Power consumption

W

Hydraulic DHW/primary circuit connections

¾” M

Dimensions (H x L x P)

mm

700 x 400 x 295

Mass

Kg

16 (18)

Max DHW flow rate (70°C , ∆T=30°)

l/min

32

PUMP GROUP

DIGIT SOLAR PUMP GROUP

Solar circuit flow rate range Max solar circuit pressure

l/min

1 ÷ 16

bar

6

Max heat transfer fluid temperature

°C

130

Electrical supply/Frequency

V/Hz

230 / 50

Power consumption

W

97

Flow and return temperature sensor

NTC (10kΩ ` =3977)

Hydraulic conections

¾” M or smooth tube ø 18 mm

Weight

kg

6.5

Dimensions (LxHxP)

mm

275 x 480 x 200

KAIROS COMBI

CK1 400

CK1 600

CK1 800

CK1 1000

Energy class

B

C

C

C

CODE

3023285

3023286

3023287

3023288

ACCESSORIES

CODE

DHW module recirculation kit

3024161

Electrical kit 1.5 kW 230 V 1”, 1/2

935393

Electrical kit 2.5 kW230-400 V 1”, 1/2

935394

Electrical kit 6 kW 400 V 1”, 1/2

3078066

Safety group

12053830

34 /

400 / 600 / 800 / 1000

*

400

600 1645 1550 1400 1294 1000 900

800 1495 1405 1315 1309 1060 950 855 775 500 260 1805 1190 990 790 690

1000 1730 1640 1550 1434 1185 1075 980

A 1240 B 1150 C 1060 D 1164 E 880

2 1

125 275

85

200

3

F

785

G 700 H 630

815 760 405 230

6 5 4

900 500 260

I

415 235

L

M 1630 N 1000 O 800 P 600 Q 695

1945 1050 850 650

2055

1190 990 790 690

7

8

720

1

1” F

1” F

1” F

1” F

2 ½” F

½” F

½” F

½” F

N

3

1” F

1” F

1” F

1” F

O

4 1” ½ F 5 ½” F 6 1” F

1” ½ F

1” ½ F

1” ½ F

P

½” F

½” F

½” F

1” F

1” F

1” F

7

½” F

½” F

½” F

½” F

8 1” F 9 1” F

1” F 1” F

1” F 1” F

1” F 1” F

9

*dimenson in mm

LIST OF COMPONENTS KAIROS COMBI

Description

KAIROS COMBI CK1 400

1

1

1

1

1

1

1

1

KAIROS COMBI CK1 600

1

1

1

1

1

1

1

1

KAIROS COMBI CK1 800

1

1

1

1

1

1

1

1

KAIROS COMBI CK1 1000

1

1

1

1

1

1

1

1

** Sensys (IT-EN-FR-ES-PT) Code 3318585; Sensys (PL-CZ-HU-RO) Code 3318615; Sensys (TK-RU-GR-HR-SRB) Code 3318613.

Grafico portate acqua sanitaria disponibili (temperatura di rete 10 °C)

Grafico portata Gruppo pompa digitale (temperatura di rete 10 °C)

Grafico portate acqua sanitaria disponibili (temperatura di rete 10°C)

700

40 45 50 55 60 65 70 75 80 85 0 5 10 15 20 25 30 35 40 45 50 set point 60°C set point 50°C set point 40°C

Velocità II

600

Velocità III

500

400

300

200

100

Portata (l/h) 0 100 200 300 400 500 600 700 800 900 1000 0

Portata sanitaria [l/min]

/ 35

KAIROS COMBI

MAIN LAYOUTS

A

C

B

*

*

C

A

B

*

*diverter valve to be ordered separately cod. 3024177

36 /

COLLECTORS FOR FORCED CIRCULATION

KAIROS XP 2.5-1V KAIROS XP 2.5-1H KAIROS ENERGY EVO KAIROS CF2.0-1

2,53

2,53

2,02

2,01

GROSS AREA (m 2 )

2,01

2,53

2,53

2,02

APERTURE AREA (m 2 )

1,83

2,26

2,26

1,89

ABSORBER AREA (m 2 )

1,74

2,24

2,24

1,83

30

EMPTY WEIGHT (kg)

46

46

30

STAGNATION TEMPERATURE (°C)

198

193

190

199

HEIGHT (mm)

61

61

78

85

LENGTH (mm)

2241

1128

2004

2006

WIDTH (mm)

1128

2241

1004

1007

INCLINED ROOF INSTALLATION

Yes

Yes

Yes

No

GROUND/FLAT ROOF INSTALLATION

Yes

Yes

Yes

Yes

BUILT-IN INSTALLATION

Yes

Yes

Yes

No

MAX NUMBER OF COLLECTORS

10

10

6

6

SOLAR KEYMARK

Yes

Yes

Yes

Yes

PAGE

38

40

44

42

/ 37

KAIROS XP 2.5-1V

Solar collector for forced circulation

PERFORMANCES / Kairos XP 2.5-1 has a serpentine absorber that makes it suitable for big systems; / The blue selective surface treatment provides very high performances with the 95% absorbtion and only 5% reflection; DESIGN AND TECHNOLOGY / Kairos XP 2.5-1 offers a very enjoyble design in its category, thanks to the accurate study of the lines, and of the external shape; / The new o-ring connection allows a very quick installation, even eliminating the risk to damage the hydraulic connection kit; QUALITY / The special tempered glass with low content iron assures very high protection against the hail, and against the collector’s loading; / The technopolymer angle, that integrates the condensate exhaust and the flanged manifold outlet, ensures a more precise production process;

TECHNICAL DATA

KAIROS XP 2.5-1V

Empty mass

Kg

46

Working pressure

bar

6

Collector pipe diameter

mm

18

2.51

Gross surface

m 2

Amount of collector liquid

l

2.1

Absorption

%

95

Emission

%

5

2.26

Aperture surface

m 2

Absorbent surface

m 2

2.24

Specific thermic capacity

kJ/K

15.32

0.81*

d 0

k 1

W/m

2 K

3.13*

W/m

2 K 2

0.016*

k 2

T stagnation

°C

198

* data refers to the aperture area *

Solar collector efficiency curve

1,0 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0,1 0,0

P peak =1.832 W

KAIROS XP

2.5-1V

CODE

3020058

0,00 0,01 0,02 0,03 0,04 0,05 0,06 0,07 0,08 0,09 0,10

(T collector liquid average -T environment )/G K/(W/m 2 ) G = 1000 W/m 2

38 /

FLAT SOLAR COLLECTOR

Up to 10 collectors

Up to 5 collectors

KAIROS XP 2.5 1V

1

2

3

4

5

6

7

8

9

10

Description

Code

TT TR IN TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN²

KAIROS XP 2.5-1 V

3020058 1 1 1 2 2 2 4 3 3 3 6 4 4 4 8 5 5 5 10 6 6 6 12 7 7 7 14 8 8 8 16 9 9 9 18 10 10 10 20

Hydraulic connec- tion set 1 collector Hydraulic connection set 1 collector ext.

1 1 1 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2

3024093

1 1 1 2 2 2 2 4 3 3 3 6 4 4 4 8 5 5 5 10 6 6 6 12 7 7 7 14 8 8 8 16 9 9 9 18

3024094

Horizontal Bars

3024104

1 1

2 2

3 3

4 4

5 5

6 6

7 7

8 8

9 9

10 10

Triangle

3024103

2

2

3

4

5

6

7

8

9

10

Inox Fixing Straps*

3024112

2

3

4

5

6

7

8

9

10

11

In-roof kit (1 collector) In-roof kit (2 collectors)

1

3721434

3721428

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

In-roof kit (additional collector) 2nd row in-roof kit (2 collectors) 2nd row in-roof kit (additional collector)

3721429

1 1

2 2

3 3

4 4

5 5

6 6

7 7

8 8

3721430

1

1

1

1

1

1

1

1

1

3721431

1

2

3

4

5

6

7

8

special fixing frame for sloped roof for xp collector

Description

Codice

Disegno

Bent tile fixing brackets (pair)

3024113

Flat tile fixing brackets (pair)

3024114

Slate tile fixing brackets (pair)

3024083

Undulating roof fixing screws (pair)

3024115

Wooden roof fixing screws (pair)

3024116

/ 39

KAIROS XP 2.5-1H

Solar collector for forced circulation

PERFORMANCES / Kairos XP 2.5-1 has a serpentine absorber that makes it suitable for big systems; / The blue selective surface treatment provides very high performances with the 95% absorbtion and only 5% reflection; DESIGN AND TECHNOLOGY / Kairos XP 2.5-1 oers a very enjoyble design in its category, thanks to the accurate study of the lines, and of the external shape; / The new o-ring connection allows a very quick installation, even eliminating the risk to damage the hydraulic connection kit; QUALITY / The special tempered glass with low content iron assures very high protection against the hail, and against the collector’s loading; / The technopolymer angle, that integrates the condensate exhaust and the flanged manifold outlet, ensures a more precise production process;

TECHNICAL DATA

KAIROS XP 2.5-1H

Empty mass

Kg

46

Working pressure

bar

6

Collector pipe diameter

mm

18

m 2

2.51

Gross surface

Amount of collector liquid

l

2.5

Absorption

%

95

Emission

%

5

m 2

2.26

Aperture surface

m 2

2.23

Absorbent surface

Specific thermic capacity

kJ/K

17.98

η 0

0.81*

2

W/m

K

3.02*

k 1

2 K 2

W/m

0.017*

k 2

T stagnation

°C

193

* data refers to the aperture area

Solar collector eciency curve

1,0 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0,1 0,0

P peak =1.832 W

KAIROS XP

2.5-1H

CODE

3020057

0,00 0,01 0,02 0,03 0,04 0,05 0,06 0,07 0,08 0,09 0,10

(T collector liquid average -T environment )/G K/(W/m 2 ) G = 1000 W/m 2

40 /

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42 Page 43 Page 44 Page 45 Page 46 Page 47 Page 48 Page 49 Page 50 Page 51 Page 52 Page 53 Page 54 Page 55 Page 56 Page 57 Page 58 Page 59 Page 60 Page 61 Page 62 Page 63 Page 64 Page 65 Page 66 Page 67 Page 68 Page 69 Page 70 Page 71 Page 72 Page 73 Page 74 Page 75 Page 76 Page 77 Page 78 Page 79 Page 80 Page 81 Page 82 Page 83 Page 84 Page 85

Made with FlippingBook Annual report