and a steam consumption of 1.2 metric tons of steam per metric ton of CO 2 captured was utilized [56]. A 0.01% CO 2 loss rate was assumed during pipeline transporta- tion [57] in a stainless steel 304 pipe [58, 59] under > 150 bar. A baseline injection power consumption of 2.77 kWh per metric ton CO 2 was used [60]. A sensitivity analysis was performed by varying these parameters (0.0014%– 5% CO 2 leakage; ± 50% injection power) to estimate their impact on net carbon removal. Similarly, a 50-mile transport distance by truck was assumed for both CCS byproduct disposal and bark supply, reflecting typical U.S. pulp and paper industry logistics. The detailed emis- sion factors used to calculate the global warming poten- tial of the CCS operation are presented in Table S6. 3 Results and discussion In accordance with the defined goal and scope, this life cycle assessment focuses exclusively on GHG emis- sions, with global warming potential (GWP) expressed in metric tonnes of CO 2 -equivalent as the primary impact category. The analysis is based on a representative kraft pulp and paper mill with an annual production capac- ity of 462,000 metric tonnes of linerboard. This refer- ence mill serves as the basis for modeling material and energy flows, estimating baseline emissions, and design- ing the integrated carbon capture system. Table 3 sum- marizes the mill’s raw material inputs, steam and power consumption, and CO 2 emissions under the baseline sce- nario (System 1). For each system configuration analyzed in the integra- tion of CCS into the pulp and paper industry—except
CO 2 is compressed to supercritical conditions (153 bar, 44 °C) for further transport and storage, as shown in Fig. 4. The steam required by the stripping column in the CCS plant was assumed to be provided by a biomass boiler. Forestry residues were considered fuel for steam genera- tion. The estimated required steam in the CCS operation for each case is presented in the supplementary informa- tion document. The carbon capture facility’s total design capacity varies according to the point sources subject to capture in the pulp and paper mill. It is assumed that a 90% capture rate with a plant usage of 96% (350 days per year, 24 h per day) [7, 8]. The capture and transportation system design lifetime is 30 years. The CO 2 capture plant cost and ancillaries, including the cost of the transport system, were estimated using data reported in the liter- ature, with the values adjusted to 2024 U.S. dollars [54]. Table S5 presents the detailed data used for the LCA of the CCS system boundary. When the CCS is evaluated independently, the energy usage in the purification of the flue stack coming into the plant is accounted for. When the CCS is integrated into the paper mill, that power con- sumption is accounted for in the point source of the flue gas fed into the CCS. The steam required in the reboiler of the stripping col- umn of the CCS is produced by the functioning of a bio- mass boiler that uses mainly bark and wood residues as fuel. A small percentage of natural gas use is considered in the biomass boiler, representing the start-up and pres- sure increase of the boiler. The capture system and CO 2 compression power consumption were determined in agreement with data reported in the literature [54, 55],
Fig. 4 Flowsheet diagram of Carbon Capture and Storage system
Made with FlippingBook Online newsletter maker