PAPERmaking! Vol12 Nr2 2026

Carrejo et al. Carbon Neutrality

(2026) 5:3

Page 30 of 35

Fig. 15 Sensitivity analysis of carbon removal efficiency as a function of electricity carbon intensity and CCS capture rate, with recovery boiler as the sole point source. Results are shown for ( a ) a narrow gate-to-gate boundary under a static CDR perspective (System 2) and ( b ) a broad cradle-to-grave boundary under a static CDR perspective (System 4). Shaded regions indicate the carbon intensity range of the U.S. Southeast grid subregion

removal also includes the biomass waste residues used to provide steam to the CCS facility. Emerging research indicates that SOC dynamics can significantly impact the net climate benefit of utilizing forest residues for bio- energy due to the associated changes in SOC, even in the absence of land-use change [64]. Future integrated assessments should, therefore, incorporate dynamic SOC models to provide a more holistic view of the technol- ogy’s climate mitigation potential under a net carbon removal efficiency metric.

emission factors tailored to the operational and regional characteristics of individual facilities. Furthermore, this study estimates the theoretical maxi- mum for carbon removal based solely on the amount of atmospheric CO 2 fixed by aboveground biomass from sustainably managed plantations. A key limitation of this approach is the exclusion of soil organic carbon (SOC) contributions, which several studies have shown to rep- resent a significant additional carbon sink within forest systems [52, 64]. The theoretical maximum for carbon

Made with FlippingBook Online newsletter maker