Coatings 2026 , 16 , 299
17of 25
ȱ Figure5. Oxygen concentration vs. time for B6 and MB6. Mean values of two repeated measurements. Lines are included in order to increase the visibility. The Kit rating values exhibited a strong correlation with the pinhole analysis (Table 4). Samples A5, A6 and MB6 achieved a Kit ranking of 12, consistent with the absence of detectable pinholes. This concordance between the Kit test and pinhole assessment was anticipated, as both methodologies evaluate barrier integrity through the penetration of non-aqueous test solutions. The results clearly demonstrate that the presence of pinholes is detrimental to high grease resistance.
4. Discussion 4.1. Interaction with Water
The reduction in pinholes observed for the thin multilayered samples dried under gentle IR power (Table 4) is governed by several dynamic processes. Primarily, the ab- sorption of the aqueous phase into the base paper or paperboard is influenced not only by the intrinsic properties of the substrate and the coating dispersion, but also by critical process parameters, including web speed, the pressure pulse exerted during application and metering, and the dwell time between application and subsequent metering and drying stages. Transport of water into the substrate may result in fibre swelling and loss of fibre network strength and consequently lead to increased surface roughness [84]. For multilayer coatings, swelling phenomena are most likely to occur during the initial coating pass, when the wet coating is in direct contact with the substrate, as proposed by Guezennec [49]. Rapid dewatering may also reduce the amount of wet coating present at the metering stage, potentially causing defects such as non-uniform coat weight distribution and blade scratches. Penetration of the coating dispersion, or just its aqueous phase, into the substrate can also compromise barrier performance and reduce tensile stiffness [62]. On the other hand, Table 4 indicates that the barrier properties are predominantly controlled by the drying strategy. Rapid drying utilising electric IR dryers that possess a maximum wave- length in the near-infrared (NIR) range helps minimise water uptake by the substrate [6,48]. However, the results presented in Table 4 clearly revealed that too intense drying is decisive for the barrier properties. The Bendtsen roughness (Table 4) and filtered Sa values (Table 5) at comparable coat weights were lower for samples produced via the multilayer coating strategy compared to
https://doi.org/10.3390/coatings16030299
Made with FlippingBook Online newsletter maker