PAPERmaking! Vol12 Nr2 2026

J Renew Mater. 2025

5

Flexural strength was evaluated on five parallel specimens measuring 170 mm × 30mm × 30mmusing a Zwick/Roell Z010 (ZwickRoell, Ulm, Germany) universal testing machine. The flexural test was conducted according to ISO 1209-2:2007 [36] under controlled laboratory conditions of 23 ○ C and 50% RH. The load was applied at a rate of 10 mm min − 1 with a 1 N pre-load, using a three-point bending configuration with a 150 mm support span. The maximum flexural strength ( σ fM) and modulus of elasticity (Ef) were calculated automatically by the software. 2.6 Thermal Conductivity Thermal conductivity measurements were performed using a Linseis HFM 200 (Linseis GmbH, Selb, Germany) in line with ISO 8301:1991 [37], with the cold and hot plates set at 0 ○ C and 20 ○ C, respec- tively, yielding a ΔT of 20 ○ C. Three replicate specimens, each measuring 200 mm × 200 mm × 30 mm, were analyzed. 2.7 Hygroscopic Sorption Hygroscopic sorption was measured in accordance with ASTM C1498-01:2017 [38]. Three specimens of each EPW biocomposite composition, measuring 30 mm × 30mm × 30 mm, were selected and dried in an oven at 50 ○ C to a constant mass. The specimens were then placed in a climate chamber Binder MKF 240 (Binder GmbH, Tuttlingen, Germany) at 23 ○ C, and exposed to a series of test environments with RH increasing from 60% to 90%. The specimens were periodically weighed until equilibrium was reached in each environment. The equilibrium moisture content (%) for each test condition was calculated based on the difference between the constant mass in each environment and the dry weight of the specimen, using Eq. (3). u ( % )= m − m 0 m 0 × 100, (3) where u is equilibrium moisture content (%), m is mean mass of the specimens at equilibrium (g), m 0 ismean mass of the dry specimens (g). Subsequently, the adsorption isotherms were constructed. 2.8 Cone Calorimetry The cone calorimetry method was used to evaluate the heat release characteristics of EPW biocompos- ites during combustion. Reaction to fire was assessed using an FTT Dual Cone Calorimeter (Fire Testing Technology Ltd., East Grinstead, UK) following ISO 5660-1:2015 [39]. Four replicate specimens measuring 100mm × 100mm × 30 mm were exposed to a constant external heat flux of 35 kW ⋅ m − 2 . The study assessed critical fire performance indicators such as time to ignition, time to flameout, total heat release, peak heat release rate, time to peak heat release rate, total smoke release, and heat release rate. 2.9 Statistical Analysis The statistical analysis was conducted using R 4.2 and the RStudio IDE. Data manipulation and summary statistics (mean and standard deviation) were handled using the dplyr package. Normality of residuals within each substrate group was assessed visually using Quantile-Quantile (Q-Q) plots generated with the qqplotr package. Homogeneity of variances across substrate groups was formally tested using Levene’s test from the rstatix . The significance of differences across groups was tested using a one-way analysis of variance (ANOVA). Tukey’s Honest Significant Difference (HSD) test was employed for post-hoc pairwise comparisons between substrate means. Differences with p < 0.05 were considered statistically significant. The correlation was quantified using Pearson’s correlation coefficient.

Made with FlippingBook Online newsletter maker