Katalog SMW-electronics 08/2024
www.smw-electronics.com
SMW-AUTOBLOK worldwide
Headquarters / Production Plants
Subsidiaries
Representatives
AUTOBLOK manufacturing plant Caprie-Torino
SMW-AUTOBLOK manufacturing plant Meckenbeuren Development | Manufacturing | Sales | Service | Support
SMW Factory Airport Meckenbeuren Production | Automation | Electronics | Clamping systems
SMW-electronics manufacturing plant Meckenbeuren Development | Manufacturing | Sales | Service | Support
Visit our website: www.smw-autoblok.com
www.smw-electronics.com
Market segements
Automotive
Industrial Equipment
OCTG
Aerospace
Electronics
Off Highway
Mold Industry
Plastics
Automation and Handling
Mining Industry Cranes
Robots / Cobots
Medical Technology
Intralogistics
Packaging Industry
Powertrain
Product range
Inductive Coupling System F280 CAN Axial coupler ■ Contact free transmission of energy and signals ■ Transmission of energy up to 1100 W ■ Transmission of signals: 2x CAN-Bus, 2 x digital ■ Diameter 280 mm ■ Dynamic Pairing ■ High transmission of energy up to 400 W ■ Transmission of signals: Ethernet 100 Base-T ■ Diameter: 180 mm / through-hole: 85 mm ■ Dynamic Pairing Inductive Coupling System F180 Ethernet Axial coupler ■ Contact free transmission of energy and signals Inductive Coupling System F100-2IOL Axial coupler ■ Contact free transmission of energy and signals ■ High transmission of energy up to 75 W ■ Transmission of signals: 2x IO-Link (COM1, COM2, COM3) ■ Diameter: 100 mm / through-hole: 50 mm ■ Dynamic Pairing Inductive Coupling System F100 Ethernet Axial coupler ■ Contact free transmission of energy and signals ■ High transmission of energy up to 75 W ■ Transmission of signals: Ethernet 100 Base-T ■ Diameter: 100 mm / through-hole: 50 mm ■ Dynamic Pairing Inductive Coupling System F60-4 / 4A Axial coupler ■ Contact free transmission of energy and signals ■ Transmission of energy up to 2.5 W ■ Transmission of signals: 4x digital, 4x analog 0 - 10 V ■ Base with mounting flange, Dynamic Pairing ■ Diameter: 60 mm / through-hole: 36 mm Inductive Coupling System F60-4 / 4A Axial coupler ■ Contact free transmission of energy and signals ■ Transmission of energy up to 2.5 W ■ Transmission of signals : 4x digital, 4x analog 0-10 V ■ Diameter: 60 mm / through-hole: 36 mm ■ Dynamic Pairing Inductive Coupling System F120 Axial coupler ■ Contact free transmission of energy ■ Transmission of energy:120 W ■ No signal transmission ■ Dynamic Pairing Inductive Coupling System F100 / 66-IOL Axial coupler ■ Contact free transmission of energy and signals ■ Transmission of energy up to 22 W ■ Transmission of signals: IO-Link (COM1, COM2, COM3) ■ Ideal for pallet change application ■ Dynamic Pairing
Inductive Coupling System M12-2 Axial coupler ■ Contact free transmission of energy and signals ■ Transmission of energy up to 1 W ■ Transmission of signals: 2x digital ■ Mounting: M12 x 1 ■ Dynamic Pairing Inductive Coupling System M18-4 Axial coupler ■ Contact free transmission of energy and signals ■ Transmission of energy up to 1.2 W ■ Transmission of signals: 4x digital ■ Mounting: M18 x 1 ■ Dynamic Pairing Inductive Coupling System M30-2 Axial coupler ■ Contact free transmission of energy and signals ■ Transmission of energy up to 12 W ■ Transmission of signals: 2x digital ■ Mounting: M30 x 1.5 ■ Dynamic Pairing Inductive Coupling System M30-8 Axial coupler ■ Contact free transmission of energy and signals Inductive Coupling System M30-IOL Axial coupler ■ Contact free transmission of energy and signals ■ Transmission of energy up to 12 W ■ Transmission of signals: IO-Link (COM1/COM2/COM3) ■ Mounting: M30 x 1.5 ■ Dynamic Pairing ■ Transmission of energy up to 12 W ■ Transmission of signals: 8x digital ■ Mounting: M30 x 1.5 ■ Dynamic Pairing Inductive Coupling System C40-IOL Axial coupler ■ Contact free transmission of energy and signals ■ Energy transmission 15 W (24 V) ■ Signal transmission: IO-Link (COM 1, COM 2, COM 3) ■ Cubical coupling system (40x45x22 mm) ■ Dynamic Pairing Inductive Coupling System C40-2x0-10V / 6PNP Axial coupler ■ Contact free transmission of energy and signals ■ Energy transmission 15 W (24 V) ■ Signal transmission: 6x PNP, 2x Analog 0-10 V ■ Cubical coupling system (40x45x22 mm) ■ Dynamic Pairing
10
Page
32
Page
34
Page
12
Page
16
Page
36
Page
20
Page
38
Page
Page
40
22
Page
42
Page
24
Page
Page
445
Page
26
Continuation on the next page
Page
28
SMW-electronics 5
Product range
Inductive Coupling System M30-8+8 Axial coupler ■ Contact free transmission of energy and signals ■ Transmission of energy up to 12 W ■ Transmission of signals: 8 / 8x digital (bidirectional) ■ Mounting: M30 x 1.5 ■ Dynamic Pairing Inductive Coupling System M30-4A Axial coupler ■ Contact free transmission of energy and signals ■ Transmission of energy up to 6 W ■ Transmission of signals: 4x analog (4 - 20 mA/0 - 10 V) ■ Mounting: M30 x 1.5 ■ Dynamic Pairing
LPS 4.0 IO Linear Positioning System ■ Inductive positioning system ■ Output analog and IO-Link interface ■ Measuring range: 14, 48, 80 and 120 mm ■ Width target / encoder unit
Page
46
62
Page
USP 4.0 250 Ultrasonic Position Measuring System ■ Non-contact distance measurement using Ultrasonic technology ■ Large measuring range: 25 - 250 mm ■ State of the art ultrasonic ■ Output signal analog: 0 - 10 V / 4 - 20 mA GFT-X 4.0 Multifunctional Gripping Force Tester ■ Wireless grip force measuring ■ Assistance systems APPs ■ Tablet IP 67 protected ■ Integrated software for clamping force / speed evaluation Software Digital products ■ App programming ■ Cloud solutions ■ SPS programming ■ Monitoring and analysis software ■ Software for mechatronic clamping systems
Page
68
Page
48
Mounting Brackets Accessories ■ Mounting brackets for inductive couplers M30, M18 und M12 ■ Simple mounting
70
Page
50
Page
HRU Hybrid rotary union
■ Contact free transmission of energy and signals ■ For 1 medium (air, oil + air, cooling, lubricant) ■ Energy transmission : 24 V / 2.5 W ■ Signal transmission: 3x Analog 0 - 10 V/ 3x Digital PNP
52
Page
74
Page
Inductive Coupling System Individual solutions ■ Individual customized adaptions ■ Customizable geometry ■ Energy and signal transmission depending on customer requirements Tool Monitoring Inductive coupling system ■ Contact less sensor technology in the rotating tool ■ For intelligent tool holders ■ Permanent power supply for integrated rotating sensors (no battery / rechargeable battery) ■ Various measurement options: Forces, vibration, angle of rotation, temperature ■ Protection class: IP67
Accessories Connectivity ■ IO-Link Hub 16x digital IN/OUT ■ IO-Link Hub 16x digital IN ■ Sensors / actuators connecting cable
76
54
Page
Page
RFID Accessories ■ Write / read station ■ Transponder ISO 15693
Page
82
56
Page
IPS 4.0 Inductive Sensors
Application Examples ■ Inductive coupling systems
■ Proximity Switches / Positioning Sensors ■ Flexible use with versatile mounting options ■ Compact and rigid design
■ LPS 4.0 ■ UPS 4.0
58
84
Page
Continuation from previous page
SMW-electronics 7
Inductive transmission of energy and signals
Contact free transmission of energy and signals via air gap
Benef its
■ Flexible installation due to the large transmission distance ■ Safe transmission even when the mobile coupler rotates ■ Also suitable for high speeds ■ Insensitive to vibrations ■ No cable breakage ■ Safe transmission of signals
■ Completely free from wear and maintenance ■ Can be used in rough conditions and also for clean room applications ■ Protected according to IP67
■ Safe transmission even through non-metallic obstacles
■ Dynamic Pairing: Base unit (stationary) can communicate with different remote units (mobile)
8 SMW-AUTOBLOK SMW-electronics
Our technical possibilities and designs of energy and signal transmission ■ Inductive energy transmission - Up to 1100 W ■ Inductive signal transmission - Analog signals (0 - 10 V / 4 - 20 mA) - Temperature signals (PT 100) - Digital switching signals - Field bus (CAN) - IO-Link (COM1, COM2, COM3) - Ethernet (compatible among others with PROFINET, Modbus, EtherNet / IP) ■ Hybrid systems - Energy transmission via slip ring / contact pins - Inductive signal transmission
Examples of geometric design for inductive energy and signal transmission
Transmission
Axial
Axial
Axial
Axial
Radial
Radial
Translational
Rotation / Linear Cylinder (also cubic)
Motion
Rotation
Rotation
Rotation
Rotation
Rotation
Linear
Ring segment / Ring
Geometry
Disc
Ring
Segment / Ring Ring / Ring
Cubic
Palletizing, automation, mechanical engineering, tool monito- ring, connector replacement
Mechanical engineering, mechatronics, collector ring replacement
Printing machines, robotics,
Packaging machines, centrifuges, process technology
Rotary indexing tables,
Mechanical engineering, process technology
Application examples
Transport systems
collector ring replacement
packaging machines
Blue: Stationary unit (base)
Orange: Mobile unit (remote)
SMW-AUTOBLOK 9 SMW-electronics
F100 Ethernet
Inductive Coupling System
■ Contact free transmission of energy and signals
Axial coupler
Application/customer benefits • Contact free transmission of energy and signals between moving / rotating and stationary components • Application examples: Robotic (END OF ARM TOOLING), Automation, Mechanical engineering • Substitution of slip ring / connector • Dynamic Pairing • Wear and maintenance free • Protective functions: temperature monitoring, foreign object detection, reverse polarity protection • Multi-level LED with good visibility Technical features • Diameter 100 mm / Through hole 50 mm
• Operating voltage 24 V / max 6 A • Transmission distance 0 - 4 mm • Transmission of energy 24 V / 75 W • Transmission of signals Ethernet 100 Base-T • Transmission bandwidth: < 5 MBit/s • Connections: M12 Ethernet (D-coded) / M12 Power (L-coded) • Protection class: IP67
Standard equipment Inductive coupler base or remote
Block diagram
24 V / 75 W
Energy
24 V / 6 A
24 V / 4 A
Controller 24 V
Power electronic
Rectier
DAV /
Control
Control
Diagnosis
DAV / Diagnosis
PLC
Ethernet 100 BaseT
Ethernet 100 BaseT
Signal transmission
Signal transmission
Base
Remote
Signals
Subject to technical changes. For more detailed information please ask our customer service.
Ethernet
Inductive coupling system F100 Ethernet
Type Id. No.
Base
Remote
0E011420
0E011421
Operating temperature (housing surface) Storage temperature Transmission distance Operating voltage Output voltage Signal transmission Ethernet (bidirectional)
-20 °C ... +60 °C -20 °C ... +60 °C 0 mm ... 4 mm
24 V
-
-
24 V (75 W)
Ethernet 100 Base-T
LED
2 LEDs 2-color
Current consumption (Base) Overload protection / short circuit protection Residual ripple Reverse polarity protection Data-Valid output Ready delay
6 A (24 V)
-
-
< 50 mV
-
max. 100 mA < 1s
10 SMW-electronics
F100 Ethernet
Inductive Coupling System
■ Stationary unit - Base ■ Mobile unit - Remote
Axial coupler
Base:
Base / Remote:
Base / Remote:
H
H1
C
H
H1
C
H
H
H1
H1
C
C
Remote:
Subject to technical changes. For more detailed information please ask our customer service.
Inductive coupling system F100 Ethernet
Base
Remote
Type Id. No.
0E011420
0E011421
A B C H
mm mm mm mm mm
100
50
13
10
25
H1
3
ɑ ß γ
27 35
degree degree degree
20 Al, GFK IP67
Housing material Protection class Weight Function Base LED Power Color
kg
0.45
0.45
Function Remote LED Power Color
Green / red
Green / red
Off » Unit not supplied with voltage (or undervoltage) On (green) » Voltage ok and mobile unit has been detected 2 Hz green 50 / 50% » Operating temperature in critical range 1 Hz green 25 / 75% » Voltage ok but no mobile unit detected 1 Hz red / green » Incompatible mobile unit detected 2 Hz red » Foreign element detected 5 Hz red » Internal error
Off » Unit not paired On (green) » Unit paired, voltage output ok Flashes 2 Hz red » Paired but short circuit Flashes 5 Hz red » Internal error
Function
Function
LED Signal transmission Ethernet Color Yellow / red
Off » No mobile unit detected On / yellow » Signal transmission ready 1 Hz yellow » Data packets are being transmitted 3 Hz yellow » 50% of the transmission bandwidth used (10 s) 8 Hz red » Data packets were discarded (in the last 10 s) On / red » Error in data transmission (internal error)
LED Signal transmission Ethernet Color Yellow / red
Off » No mobile unit detected On / yellow » Signal transmission ready 1 Hz yellow » Data packets are being transmitted 3 Hz yellow » 50% of the transmission bandwidth used (10 s) 8 Hz red » Data packets were discarded (in the last 10 s) On / red » Error in data transmission (internal error)
Function
Function
SMW-electronics 11
F100-2IOL
Inductive Coupling System
■ Contact free transmission of energy and signals
Axial coupler
Application/customer benefits • Contact free transmission of energy and signals between moving / rotating and stationary components • Application examples: Robotic (End of Arm Tooling), Automation, Mechanical engineering • Substitution of slip ring / connector • Dynamic Pairing • Wear and maintenance free • Protective functions: temperature monitoring, foreign object detection, reverse polarity protection • Status LED with good visibility Technical features • Diameter 100 mm / Through hole 50 mm • Operating voltage 24 V / max. 6 A • Transmission distance 0 - 4 mm • Transmission of energy 24 V / 75 W • Transmission of signals: 2x IO-Link (COM 1, COM 2, COM 3) • Connections: Base: 2x M12 x 1 male 5-pin, Remote: 2x M12 x 1 female 5-pin • Protection class: IP67
Standard equipment Inductive coupler base or remote
Block diagram
24 V / 75 W
Energy
24 V / 2x 3 A
24 V / 4 A
Controller 24 V
Power electronic
Rectier
Control
Control
Diagnosis
DAV /
Diagnosis
IO-Link Master 1,2
2 x IO-Link
2 x IO-Link
Signal transmission
Signal transmission
Base
Remote
Signals
2x IO-Link COM1, COM2, COM3
Subject to technical changes. For more detailed information please ask our customer service.
Inductive coupling system F100-2IOL
Type Id. No.
Base
Remote
0E012330
0E012331
Operating temperature (housing surface) Storage temperature Transmission distance Operating voltage Output voltage Signal transmission
-20 °C ... +60 °C -20 °C ... +60 °C 0 mm ... 4 mm
24 V
-
-
24 V (75 W)
2x IO-Link (COM2, COM 2, COM 3)
LED
2 LEDs 2-color
Current consumption (Base) Overload protection / short circuit protection Residual ripple Reverse polarity protection Data-Valid output Ready delay
6 A (24 V)
-
-
< 50 mV
-
max. 100 mA < 1 s
12 SMW-electronics
2,9
H H1
F100-2IOL
Inductive Coupling System
■ Stationary unit - Base ■ Mobile unit - Remote
Axial coupler
Base / Remote:
Base / Remote:
Base:
Remote:
C
12,9
C
10,5
12,9
12,9
2,8
2,9
H H1
2,9
H H1
2,9
H H1
C
C
10,5
X1, X2
X1, X2
2,8
C
C
2
2
C
10,5
C
10,5
3
1
2,8 1
5
5 3
2,8
4
4
2x Male connector 5-pin M12 x 1
2x Female connector 5-pin M12 x 1
Subject to technical changes. For more detailed information please ask our customer service.
Inductive coupling system F100-2IOL
Base
Remote
Type Id. No.
0E012330
0E012331
A B C H
mm mm mm mm mm
100
50
1
25
H1
3
ɑ ß γ
35 20
degree degree degree
45.5 Al, GFK IP67
Housing material Protection class Weight Function LED IO-Link Base (X1, X2) LED Power Color Yellow / red
kg
0,224
0,237
Function LED IO-Link Remote (X1, X2) LED Power Color Yellow / red
Yellow » SIO mode active and SIO signal is high
Yellow » SIO mode active and SIO signal is high
Flash yellow (1000 ms on, 100 ms off),» IO-Link communica- tion active, power is on, Base has been detected Flashing 2 Hz yellow » No IO-Link communication, power on, no Base detected
Flash yellow (1000 ms on, 100 ms off), » IO-Link communica- tion active, power is on, Remote was detected Flashing 2 Hz yellow » no IO-Link device detected, power on, no Remote detected Flashing 2 Hz red » Short circuit on IO-Link PIN Flashing 5 Hz red » Overload voltage output Remote
Function
Function
Flashing 2 Hz red » Short circuit on IO-Link PIN Flashing 5 Hz red » Overload voltage output Base
PIN assignment Supply voltage Data-Valid Ground IO-Link Signal -
24 V IN X1 Base DAV 24 V
24 V IN X2 Base
X1 Remote
X2 Remote
PIN 1
24 V OUT
24 V OUT
2 3 4 5
-
-
-
GND
GND
GND
GND
IO-Link CQ
IO-Link CQ
IO-Link CQ
IO-Link CQ
-
-
-
-
SMW-electronics 13
F100-2IOL F100- ETH
Inductive Coupling Systems
■ Ordering overview flange
Axial coupler
Standard flange
12,9 12,9
12,9 12,9
Typ Type
IC-Base F100-2IOL D100/050
IC-Base F100-ETH D100/050
Id.-No.
0E012330
0E011420
A B
100
50
B1 B2
- -
H1 H1
H1 H1
H
25
H H
H H
H1
3
Outer flange with feed-through
12,9 12,9
12,9
Typ Type
IC-Base F100-2IOL D122/050
IC-Base F100-ETH D122/050 12,9 8,4
4x90° 4x90°
8,4
Id.-No.
0E012332
0E012320
A B
122 100
B1 B2
50
-
H
25
H1 H1
H1 H1
H1
3
H H
H H
Inner flange with feed-through
12,9
12,9
Typ Type
IC-Base F100-2IOL D100/028
IC-Base F100-ETH D100/028
Id.-No
0E012334
0E012322
A B
100
50 28
B1 B2
-
H1
H1
H1
H1
H
25
H
H
H1
3
Flangering with feed-through
12,9
Typ Type
IC-Base F100-2IOL D100/042
IC-Base F100-ETH D100/042
4x90° 4x90°
12,9 8,4
8,4
Id.-No
0E012336
0E012324
A B
100
50 42
B1 B2
-
H
25 10
H1
H1
H1
H
H1
H1
H
FURTHER OPTIONS AVAILABLE ON REQUEST! • Outer flange without feed-through • Inner flange without feed-through • Threaded sleeve with without feed-through
14 SMW-electronics
Notes
SMW-electronics 15
F180 Ethernet
Inductive Coupling System
■ Contact free transmission of energy and signals
Axial coupler
Application/customer benefits • Contact free transmission of energy and signals between moving / rotating and stationary components • Application examples: Packaging machines, special machines, automation, machine tools, printing machines, robot applications (EOAT) • Substitution of slip ring / connector • Dynamic Pairing • Wear and maintenance free • Protective functions: Temperature monitoring, foreign object detection • Status LED with good visibility Technical features • Diameter: 180 mm / Through hole: 85 mm • Operating voltage: 24 V or 48 V • Transmission distance: 0 - 5 mm at 24 V or 0 - 3 mm at 48 V • Energy transmission: 24 V / 240 W or 48 V / 400 W (adjustable) • Signal transmission: Ethernet 100 Base-T • Transmission bandwidth < 5 MBit/s • Connections: M12 Ethernet (D-coded), M12 Diagnosis (A-coded), terminal block (Energy) • Protection class: IP67
Standard equipment Inductive coupler base oder remote
Block diagram
24 V / 240 W 48 V / 400 W
Energy
48 V / 8.3 A Actuator
Controller 24 V / 48 V
24 V / 10 A Actuator
24 V /
Power electronic
Rectifier
48 V
24 V / 2 A Sensor
Controller 24 V
Actuator OFF
DAV / Diagnosis
Control
Control
DAV / Diagnosis
PLC
Ethernet 100BaseT
Ethernet 100BaseT
Signal transmission
Signal transmission
Base
Remote
Signals
Ethernet
Subject to technical changes. For more detailed information please ask our customer service.
Inductive coupling system F180 Ethernet
Base
Remote
Type Id. No.
0E011246
0E011247
-20° C ... +60° C -20° C ... +60° C
Operating temperature (body surface) Stocking temperature
0 mm ... 5 mm (24 V) 0 mm ... 3 mm (48 V)
Transmission distance
24 V / 48 V
-
Operating voltage
24 V DC / 10 A 48 V DC / 8.3 A 24 V DC / 4 A
-
Output voltage (Actuator supply)*
-
Output voltage (Sensor supply)* Signal transmission
Ethernet 100 Base-T
LED function display
3 LEDs 2-color
15 A (24 V) 12 A (48 V)
-
Current consumption (base)
Overload protection / short-circuit protection Reverse polarity protection Data valid output Ready delay
-
< 50 mV
max. 100 mA
-
< 5 s
*max 400 W total
16 SMW-electronics
F180 Ethernet
Inductive Coupling System
■ Stationary Unit - Base ■ Mobile Unit - Remote
Axial coupler
Base:
Base / Remote:
Base / Remote:
C
H
C
H
H 1
H 1
Remote:
Subject to technical changes. For more detailed information please ask our customer service.
Inductive coupling system F180 Ethernet
Base
Remote
Type Id. No.
0E011246
0E011247
A B
mm mm mm mm mm mm mm mm mm
180
85 93
B1
C D
29.5
57 20
E F
5
H
34
H1
7
ɑ
60 Al, GFK IP67
degree
Housing material Protection class Weight
kg
1,172
1,275
Function Base LED Power Color
Function Remote LED Actuator Color
Green / red
Green / red
Off » Unit not supplied with voltage (or undervoltage) On (green) » Voltage ok and mobile unit has been detected 2 Hz green 50/ 50% » Operating temperature in critical range 1 Hz green 25/75% » Voltage ok but no mobile unit detected 1 Hz red / green » Incompatible mobile unit detected 2 Hz red » Foreign element detected 5 Hz red » Internal error
Off » Unit not paired On (green) » Unit paired, voltage output actuator ok Flashes 2 Hz red » Unit paired but short circuit on actuator Flashes 5 Hz red » Internal error
Function
Function
LED Sensor supply Color
Green / red
Off » Unit not paired On (green) » Unit paired, voltage output sensor (24 V) ok Flashes 2 Hz red » Unit paired but short circuit on sensor (24 V) Flashes 5 Hz red » Internal error
LED Signal transmission Ethernet Color Yellow / red
Function
Off » No mobile unit detected On / yellow » Signal transmission ready 1 Hz yellow » Data packets are being transmitted 3 Hz yellow » 50% of the transmission bandwidth used (10 s) 8 Hz red » Data packets were discarded (in the last 10 s) On / red » Error in data transmission (internal error)
LED Signal transmission Color Yellow / red
Function
Off » No mobile unit detected On / yellow » Signal transmission ready
Flashes 1 Hz yellow » Data packets are being transmitted Flashes 3 Hz yellow » 50% of the transmission bandwidth used (10 s) Flashes 8 Hz red » Data packets were discarded (in the last 10 s) On / red » Error in data transmission (internal error)
LED Energy transmission Color Yellow / red
Function
Off » No mobile unit detected On (yellow) » Unit coupled, voltage output ok
1 Hz red / yellow » Short circuit at voltage output sensor 3 Hz red / yellow » Short circuit at voltage output actuator 3 Hz red » Short circuit at both voltage outputs 5 Hz red » Internal error
Function
SMW-electronics 17
F180 Ethernet
Inductive Coupling System
■ Ordering review flanges
Axial coupler
Standard flange
H
H
30
30
H
H
Type
IC-Base F180 Ethernet D180/085 0E011246 30
30
Id.-No.
A B
180
85 93
B1 B2
7
7 H1
-
H2
H2
H1
H
34
H1 H2
4 7
7
7 H1
H2
H2
H1
Outer flange with feed-through
H
IC-Base F180 Ethernet D202/085 0E012340 30 H 10,3
Type
30
H
Id.-No.
30 H 10,3
30
A B
202
85 93
B1 B2
-
H
34
H1 H2
4 7
7
7 H1
H1
H2
7
7 H1
H1
H2 Inner flange with feed-through
H
30
H
Type
IC-Base F180 Ethernet D180/063 0E012342
30
Id.-No.
A B
180
85 93 63 34
B1 B2
7
H2
H1
H
H1 H2
4 7
7
H2
H1
Flange ring with feed-through
30 H 10,3
Type
IC-Base F180 Ethernet D180/064 0E012344
Id.-No.
30 H 10,3
A B
180
64
B1 B2
- -
H
34
H1 H2
4
7
-
H1
7
H1
FURTHER OPTIONS AVIABLE ON REQUEST! • Outer flange without feed-through • Inner flange without feed-through • Threaded sleeve with feed-through
18 SMW-electronics
Notes
SMW-electronics 19
F280 CAN
Inductive Coupling System
Application/customer benefits • Contact free, safe transmission of energy and signals between moving / rotating and stationary components • Connection from mechatronic clamping systems (MM / RT e-motion line) within machine tools, slip ring replacement • Dynamic Pairing • Free from wear and maintenance Technical features • Operating voltage 60 V ± 10% • Energy transmission: 60 V / 1100 W (18 A) actuators, 24 V (2 A) sensors • Signal transmission: Bus system 2x CAN BUS • Signal transmission: Digital 2x 24 V switching signal remote to base • Diameter 280 mm • Transmission distance 0 - 3 mm • Inverse-polarity protection (base), short-circuit proof (remote) • Protection class: IP67 ■ Contact free transmission of energy and signals
Axial coupler
Standard equipment Inductive coupler base or remote
Block diagram
Energy
0 - 3 mm
60 V DC actuator
60 V IN DC
24 V DC sensor
CAN 1
CAN 1
CAN 2
CAN 2
Digital signal 1
Digital signal 1
Digital signal 2
Digital signal 2
Base
Remote
Signals
Subject to technical changes. For more detailed information please ask our customer service.
20 SMW-electronics
F280 CAN
Inductive Coupling System
Dimensions and technical data
Axial coupler
Base:
Remote:
C C1
C C1
C
C
C1
C2
C1
C2
D1
D1
14
14
B
B
Subject to technical changes. For more detailed information please ask our customer service.
Inductive coupling system F280 CAN
Base
Remote
Type Id. No.
208004
208005
A B C
mm mm mm mm mm mm mm mm mm mm mm mm
280
277
320
45 15
37 6.4
C1 C2
6
-
D
20
23 30
D1
-
E F
210 225
290
-
G
10
11
G1
5.5
6.6 M6
H
-
Housing material Protection class Operating temperature Storage temperature Transmission distance Weight Operating voltage Output voltage actuator Output voltage sensor Power consumption (Base)
Al, PA12 IP67
-10° C ... +50° C -25° C ... +70° C 0 mm ... 3 mm
kg
4.54
-
60 V DC
-
- -
60 V DC 24 V DC
< 25 A
-
Max. 18 A Aktuator (60 V) / max. 2 A Sensor (24 V)
-
Power output (Remote)
Overload protection / short circuit protection Residual ripple Reverse polarity protection Ready delay
-
< 5 V
-
< 800 ms
SMW-electronics 21
F100 / 66-IOL
Inductive Coupling System
■ Contact free transmission of energy and signals ■ Ideal for pallet change applications
Axial coupler
Application/customer benefits • Contact free transmission of energy and signals between moving / rotating and stationary components • Application examples: Supply of sensors and valves in pallet change applications • Dynamic Pairing • Wear and maintenance free • Protective functions: Temperature monitoring, foreign object detection, reverse polarity protection Technical features • Mounting 4 x M5 x 20, pitch circle Ø 84 mm • Axial installation sealing • Operating voltage 24 V (18 ... 30 V) • Transmission distance 0 - 5 mm • Transmission of energy: 24 V / 22 W • Transmission of signals: IO-Link (COM1, COM2, COM3) • Connection: Base male connector M12 x 1 (5-pin), remote female connector M12 x 1 (5-pin) • Protection class: IP67
Standard equipment Inductive coupler base or remote
Block diagram
IO-Link Master
24 V / 22 W
Energy
Remote
Base
IO-Link-Device
0 - 5 mm
Signals
IO-Link COM1, COM2, COM3
Subject to technical changes. For more detailed information please ask our customer service.
22 SMW-electronics
F100 / 66-IOL
Inductive Coupling System
■ Contact free transmission of energy and signals ■ Ideal for pallet change applications
Axial coupler
Base/ Remote:
O-Ring Ø 70 x 2
4x90°
C
D
E
B
F
M6
Base
Remote
Ø 84
2
2
M5 x 20 DIN ISO 4762 max. tightening torque 1 Nm
3
1
5
3
5
1
4
4
Male connector 5-pin M12 x 1
Female connector 5-pin M12 x 1
Subject to technical changes. For more detailed information please ask our customer service.
Inductive coupling system F100/66-IOL
Base
Remote
Type Id. No.
0E012280
0E012290
A B C D
mm mm mm mm mm mm
100 - 0.1 66 - 0.1 20 - 0.1
15 12
E F
M12 x 1 / Male
M12 x 1 / Female
Housing material Protection class Operating temperature
PA 12 C, AL IP67
-20° C ... +50° C -20° C ... +80° C 0 - 5 mm
Storage temperature Transmission distance Weight Operating voltage Output voltage Power consumption (Base) Power output (Remote) Overload protection / short circuit protection Residual ripple
kg
-
-
24 V (18 ... 30 V)
-
-
24 V ± 10% DC
1600 mA
-
-
920 mA
-
< 200 mV
Reverse polarity protection Temperature monitoring Data-Valid Output Ready delay PIN assignment
-
150 mA
-
< 600 ms
Signal Base
Signal Remote
Supply voltage Digitalsignal Ground IO-Link Signal Data-Valid
1 2 3 4 5
24 V IN
24 V OUT 0/24 V IN
0/24 V OUT
GND
GND
IO-Link CQ DAV 24 V
IO-Link CQ
-
SMW-electronics 23
F60-4 / 4A
Inductive Coupling System
Application/customer benefits • Contact free transmission of energy and signals between moving / rotating and stationary components • Application example: Monitoring of sensors in clamping systems, automation, slip ring replacement • Base with mounting flange • Dynamic Pairing • Operating voltage 24 V ± 10% • Transmission distance 0 - 3 mm • Energy transmission: 24 V / 2.5 W (100 mA) • Transmission of signals: 4 analog signals (0 - 10 V) / 4 digital signals (PNP) • Inverse-polarity protection (base), short-circuit proof (remote) • Protection class: IP67 • Wear and maintenance free Technical features ■ Contact free transmission of energy and signals
Axial coupler
Standard equipment Inductive coupler base or remote
Block diagram
up to 4 analog signals
Energy
0 - 3 mm
Base
Remote
Signals
up to 4 digital signals
Subject to technical changes. For more detailed information please ask our customer service.
24 SMW-electronics
F60-4 / 4A
Inductive Coupling System
■ Stationary unit - Base ■ Mobile unit - Remote
Axial coupler
Base:
Remote:
A
A
C1
C1
A
C
B
B
1
1
ØD
ØD
ØD
C
C
Subject to technical changes. For more detailed information please ask our customer service.
Inductive coupling system F60-4/4A
Base
Remote
Type Id. No.
0E010972
0E010973
A B C
mm mm mm mm mm mm
60
51 14
-
12
C1
13 36
D
D1
64
-
Housing material Protection class Operating temperature
POM, PA66, PC GF 30% IP67 0° C ... +60° C -10° C ... +70° C 0 mm ... 3 mm
Storage temperature Transmission distance Weight Operating voltage Output voltage Power consumption (Base) Power output (Remote) Overload protection / short circuit protection Residual ripple Reverse polarity protection Data-Valid Output Ready delay
kg
0.25
0.23
24 V ± 10% DC
-
-
24 V ± 10% DC
< 300 mA
-
-
< 100 mA
-
< 200 mV
- -
0 / 24 V
≤ 100 ms
SMW-electronics 25
F60-4 / 4A
Inductive Coupling System
Application/customer benefits • Contact free transmission of energy and signals between moving / rotating and stationary components • Application examples: Robotics, slip ring replacement • Dynamic Pairing • Wear and maintenance free Technical features ■ Contact free transmission of energy and signals • Operating voltage 24 V ± 10 % • Transmission distance 0 - 3 mm • Transmission of energy: 24 V / 2.5 W (100 mA) • Transmission of signals: 4 analog signals (0 - 10 V) / 4 digital signals (PNP) • Inverse-polarity protection (base), short-circuit proof (remote) • Protection class: IP67
Axial coupler
Standard equipment Inductive coupler base or remote
Block diagram
PLC
up to 4 analog signals
Energy
0 - 3 mm
Base
Remote
Signals
up to 4 digital signals
Subject to technical changes. For more detailed information please ask our customer service.
26 SMW-electronics
F60-4 / 4A
Inductive Coupling System
■ Stationary Unit - Base ■ Mobile Unit - Remote
Axial coupler
Base:
Remote:
B
B
B
B
Subject to technical changes. For more detailed information please ask our customer service.
Inductive coupling system F60-4/4A
Base
Remote
Type Id. No.
0E010974
0E010975
A B C
mm mm mm
Ø 60
10
12
Ø 36 POM, PA66, PC GF 30% IP67 0° C ... +60° C -10° C ... +70° C 0 mm ... 3 mm
Housing material Protection class Operating temperature
Storage temperature Transmission distance Weight Operating voltage Output voltage Power consumption (Base) Power output (Remote) Overload protection / short circuit protection Residual ripple Reverse polarity protection Data-Valid Output Ready delay
kg
0.14
0.17
24 V ± 10% DC
-
-
24 V ± 10% DC
< 300 mA
-
-
< 100 mA
≤ 200 mV
-
- -
0 / 24 V
≤ 100 ms
SMW-electronics 27
F120
Inductive Coupling System
■ Contact free transmission of energy
Axial coupler
Application/customer benefits • Contact free transmission of energy (power only) between moving / rotating and stationary components • Application examples: Automation, replacement of slip ring • Dynamic Pairing • Wear and maintenance free Technical features • Flange mounting 120 x 120 mm (Diameter 116 mm)
• Operating voltage 24 V ± 10% • Transmission distance 0 - 4 mm • Transmission of energy 24 V / 120 W • Inverse-polarity protection (base), short-circuit proof (remote) • Connections: Base male connector 7/8“ (5-pin), remote female connector 7/8“ (5-pin) • Protection class: IP67
Standard equipment Inductive coupler base or remote
Block diagram
PLC
Energy
0 - 4 mm
Electric lead (max. 5 A)
Base
Remote
Subject to technical changes. For more detailed information please ask our customer service.
28 SMW-electronics
F120
Inductive Coupling System
■ Stationary Unit - Base ■ Mobile Unit - Remote
Axial coupler
Base/Remote:
Base/Remote:
A B
C
A B
E
Base
Remote
3
3
3
3
D
2
2
4
2
4
2
4
4
5
5
5
5
1
1
1
1
Male connector 5-pin 7/8"
Female connector 5-pin 7/8"
3
3
1
3
1
3
1
1
Subject to technical changes. For more detailed information please ask our customer service.
Inductive coupling system F120
2
2
2
2
4
4
4
4
Base
Remote
Type Id. No.
0E010983
0E010984
A B C D
mm mm mm mm mm
120
99 45
145
148.5
E
5 Al, PA66, PC GF 30% IP67 0° C ... +50° C -10° C ... +70° C 0 mm ... 4 mm
Housing material Protection class Operating temperature
Storage temperature Transmission distance Weight Operating voltage Output voltage Power consumption (Base) Power output (Remote) Overload protection / short circuit protection Residual ripple Reverse polarity protection Data-Valid Output Ready delay PIN assignment
kg
0.9
0.9
24 V ± 10% DC
-
-
24 V ± 10% DC
< 10 A
-
-
< 5 A
-
< 200 mV
- -
-
< 500 ms
PIN 1
Signal Base
Signal Remote
GND GND
Ground Ground PE Protective earth
2 3 4 5
PE
24 V IN 24 V IN
24 V OUT 24 V OUT
Voltage supply Voltage supply
SMW-electronics 29
C40 AUTOMATION PRODUCT FAMILY
Hybrid Dynamic Pairing
OPERATION with IO-Link sensors (Devices)
C40 IOL REMOTE
• C40 remote units are compatible with each other and can be be combined
C40 IOL BASE
• Consistent IO-Link functionality
OPERATION of 2 analog (0-10V) + 6 digital (PNP) signals direction switchable (bidirectional)
C40 2x 0-10V / 6PNP REMOTE
• Identification via IO-Link parameters device name, • IO-Link tag possible
C40 IOL BASE
Application example of change systems (Pallet change, tool change, format change): Remote - interchangeable units Variants: Combination of 2 C40 systems
C40 2x 0-10V / 6PNP Remote
1x IOL + 2x 0-10V + 6x PNP C40 IOL REMOTE C40 2x 0-10V / 6PNP Remote
C40 2x 0-10V / 6PNP Remote
C40 IOL REMOTE
C40 IOL REMOTE
2x IOL
4x 0-10V + 12x PNP
Exchange pallet
C40 IOL Base
C40 IOL Base
STATIONARY
30 SMW-electronics
Hybrid Dynamic Pairing C40 IOL BASE + C40 IOL REMOTE or C40-2x 0-10V / 6x PNP REMOTE
IO-Link Device (sensor)
2x Analog signals 0-10V and 6x PNP digital switching signals
2x 0-10V
6x PNP
IO-Link and analog/digital remote can be switched dynamically during operation.
C40 2x 0-10V / 6PNP Remote
C40 IOL REMOTE
no signals
1x IOL
WITHOUT REMOTE
2x 0-10V + 6x PNP
The remote exchangeable pallets can be changed dynamically during operation with the stationary C40 IOL Base unit .
SMW-electronics 31
C40-IOL
Inductive Coupling System
Application/customer benefits • Contact free transmission of energy and signals between moving and stationary components • Application examples: Operation of sensors in gripper changing systems (EOAT) and pallet change applications • Plug & work retrofit kits • Dynamic Pairing • Wear and maintenance free • Protective functions: Temperature monitoring, foreign object detection, ■ Contact free transmission of energy and signals ■ Ideal for gripper changing systems and pallet change applications
Axial coupler
reverse polarity protection Technical features • Mounting via 2x M4 mounting screws (stainless steel) • Operating voltage 24 V (18 ... 30 V) • Transmission distance 0 - 3 mm • Transmission of energy 24 V / 15 W • Transmission of signals: 1 x IO-Link (COM 1, COM 2, COM 3) • Connections: Base: M12 x 1 male 5-pin, Remote: M12 x 1 female 5-pin • Protection class: IP67 Standard equipment Inductiv coupler base or remote with each 2 mounting bolts
Block diagramm
PLC
24 V / 15 W
Energy
IO-Link-Device
0 - 3 mm
Signals
IO-Link COM1, COM2, COM3
Subject to technical changes. For more detailed information please ask our customer service.
32 SMW-electronics
C40-IOL
Inductive Coupling System
■ Contact free transmission of energy and signals ■ Ideal for gripper changing systems and pallet change applications
Axial coupler
G
A
B D
2 x M4
Base
Status LED
Power LED
Remote
G
Remote
Base
2 x M4
2
2
3
1
3
5
5
1
4
4
Male connector 5-pin M12 x 1
Female connector 5-pin M12 x 1
Subject to technical changes. For more detailed information please ask our customer service.
Inductive coupling system C40-IOL
Base
Remote
Type Id. No.
0E012615
0E012616
A B C D
mm mm mm mm mm mm mm
45 40 22 32 11
E F
9.5
G
13
10.6
Housing material Protection class Operating temperature
AL, V2A, FR4 IP67
-25° C ... +50° C -25° C ... +80° C 0 - 3 mm
Storage temperature Transmission distance Weight Operating voltage Output voltage Power consumption (Base) Power output (Remote) Overload protection / short circuit protection Residual ripple
kg
0,087
0,086
24 V (18 ... 30 V)
-
-
24 V ± 10% DC
2000 mA
-
-
625 mA
-
< 200 mV
Reverse polarity protection Temperature monitoring Data-Valid Output Ready delay PIN assignment
-
150 mA
-
< 600 ms
Signal Base
Signal Remote
Supply voltage Digitalsignal Ground IO-Link Signal Data-Valid
1 2 3 4 5
24 V IN
24 V OUT
-
-
GND
GND
IO-Link CQ DAV 24 V
IO-Link CQ
-
SMW-electronics 33
C40-2x 0-10V / 6PNP
Inductive Coupling System
Application/customer benefits • Contact free transmission of energy and signals between moving and stationary components • Application examples: Operation of sensors in gripper changing systems (EOAT) and pallet change applications • Integrated IO-Link sensor hub • Plug & work retrofit kits • Dynamic Pairing • Wear and maintenance free • Protective functions: Temperature monitoring, foreign object detection, ■ Contact free transmission of energy and signals ■ Ideal for gripper changing systems and pallet change applications ■ Integrated IO-Link sensor hub
Axial coupler
reverse polarity protection Technical features • Mounting via 2 x M4 mounting screws (stainless steel) • Operating voltage 24 V (18 ... 30 V) • Transmission distance 0 - 3 mm • Transmission of energy 24 V / 15 W • Transmission of signals: 6x PNP, 2x Analog 0 - 10 V • Connections: Base: • Protection class: IP67 Standard equipment Inductiv coupler base or remote with each 2 mounting bolts
M12 x 1 male 12-pin, Remote: M12 x 1 female 12-pin
Block diagram
PLC
2 analog signals (0 - 10 V)
24 V / 15 W
Energy
6 digital signals
0 - 3 mm
Signals
Subject to technical changes. For more detailed information please ask our customer service.
34 SMW-electronics
C40-2x 0-10V / 6PNP Axial coupler
Inductive Coupling System
■ Contact free transmission of energy and signals ■ Ideal for gripper changing systems and pallet change applications ■ Integrated IO-Link sensor hub
G
A
B D
2 x M4
Base
Status LED`s
Remote
G
Base
Remote
2 x M4
2
2
3
3
4
4
10
10
11
11
1
1
5
5
12
12
9
9
6
6
8
8 7
7
Male connector 12-pin M 12 x 1
Female connector 12-pin M 12 x 1
Subject to technical changes. For more detailed information please ask our customer service.
Inductive coupling system C40-2x 0-10V / 6PNP
Base
Remote
Type Id. No.
0E012720
0E012721
A B C D
mm mm mm mm mm mm mm
45 40 22 32 11
E F
9.5
G
13
10.6
Housing material Protection class Operating temperature
AL IP67
-25° C ... +50° C -25° C ... +80° C 0 - 3 mm
Storage temperature Transmission distance Weight Operating voltage Output voltage Power consumption (Base) Power output (Remote) Overload protection / short circuit protection Residual ripple Reverse polarity protection Temperature monitoring Data-Valid Output Ready delay Ready for operation (switching on the entire system) Ready for operation (approach remote to switched-on base) Delay on signal change (analog signal / digital signal) PIN assignment
kg
0,087
0,086
24 V (18 ... 30 V)
-
-
24 V ± 10% DC
2000 mA
-
-
625 mA
-
< 200 mV
-
150 mA
-
< 600 ms < 1200 ms < 600 ms < 20 ms / <10 ms
Signal Base
Signal Remote
Supply voltage Ground
1 2 3 4 5 6 7 8 9
24 V IN
24 V OUT
GND
GND
Digital signal 1 Digital signal 2 Digital signal 3 Digital signal 4 Digital signal 5 Digital signal 6 Analog signal 1 Analog signal 2 Ground Analog signal Data-Valid
0/24 V OUT 0/24 V OUT 0/24 V OUT 0/24 V OUT 0/24 V OUT 0/24 V OUT
0/24 V IN 0/24 V IN 0/24 V IN 0/24 V IN 0/24 V IN 0/24 V IN
0 ... 10 V OUT 0 ... 10 V OUT Analog GND *
0 ... 10 V IN 0 ... 10 V IN
10 11 12
Analog GND *
DAV 24 V
-
* For analog operation, analog GND and GND must be connected externally.
SMW-electronics 35
Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42 Page 43 Page 44 Page 45 Page 46 Page 47 Page 48 Page 49 Page 50 Page 51 Page 52 Page 53 Page 54 Page 55 Page 56 Page 57 Page 58 Page 59 Page 60 Page 61 Page 62 Page 63 Page 64 Page 65 Page 66 Page 67 Page 68 Page 69 Page 70 Page 71 Page 72 Page 73 Page 74 Page 75 Page 76 Page 77 Page 78 Page 79 Page 80 Page 81 Page 82 Page 83 Page 84 Page 85 Page 86 Page 87 Page 88Made with FlippingBook Publishing Software