MICROSCOPE UNITS AND OBJECTIVES (UV, NUV, VISIBLE & NIR REGION)
PRE 1457(5)
Wide range of microscope units and objective lenses lineup based on Mitutoyo's proprietary optical technologies and precision processing technologies cultivated over many years.
Used by customers around the world for a wide variety of applications.
Applications : Production of semiconductors, electronics, liquid crystals, etc.
Optical systems for quality control systems and experimental research equipment Built-in optical units for visual inspection systems Observation of microorganisms and other moving objects
* We also accept custom orders for products not listed in this catalog, so please feel free to contact us for more information.
2
Ref.:“Microbio-World Ver.7,” >(http://elfe.miyakyo-u.ac.jp/opac/2008/03/cd_2.html)
3
Applications
Optical inspection with wide field of view
White light interference analysis
WLI-U + interference objective lens *System example with fixed stand/stage
WIDE VMU-HR
Lineup supporting various observation methods, including bright-field, dark- field, polarizing, differential interference, near infrared, high resolution, etc. Inspection process can be streamlined with wide field of view model.
Compact design realizes non-contact high-accuracy fine surface shape analysis through white light interference. ⇒ 3D shape measurement, 3D roughness measurement
Laser fine machining
IR analysis/inspection
Flaking of polyimide membrane
WIDE VMU-HR + NIR objective
UV laser application using VMU-L4B (Source of photographs: V-Technology Co.,Ltd.)
Infrared analysis inspection is possible in combination with a microscope unit supporting NIR series objective lenses. > Transmission analysis of silicon materials > Non-destructive evaluation of MEMS interiors > Internal observation of semiconductor packages (IC)/wafer junction void evaluation > Infrared spectral characteristics analysis, etc.
Objectives compatible with YAG lasers (1064 nm, 532 nm, 355 nm and 266 nm) allow high precision and quality work. > Removal of protective films/organic films, etc. > Cutting of IC wiring (Au, Al) and exposure of lower layer pattern > Fine photomask and FPD repair, etc Color filter working
High/low magnification microscope (dual-camera)
All-focus image generation
2/3 inch Camera (low magnification)
1/2 inch Camera (high magnification)
Two cameras can be used by mounting a constant magnification camera mount on the VMU-LB/LB4 laser port. ⇒ The same area can be observed simultaneously at different magnification (Low magnification: 2/3" camera, high magnification: 1/2" camera, etc.)
TAGLENS-T1
Ultra-high-speed focus range variation from low to high magnification lens, no mechanical vertical drive for focused images, arbitrary cross-section image acquisition possible. *For details, see the No. 14025 TAGLENS catalog
4
Contents Microscope unit for incorporating in equipment VMU ....................................................................................... 6 White Light Interference optical Unit WLI-U ............................................................................................. 16 Microscope unit FS70 ...................................................................................... 20 Objectives for bright-field (long working distance) M Plan Apo ...................................................................... ・ 26 Objectives for bright-field (with cover-glass thickness compensation) G Plan Apo ....................................................................... 2・8 Objectives for bright/dark-field (long working distance) BD Plan Apo .................................................................... 2・9 Near-infrared objectives for bright-field M Plan Apo NIR ............................................................. ・ 30 Near-infrared objectives for bright-field (with cover-glass thickness compensation) LCD Plan Apo NIR ......................................................... ・ 31 Near-ultraviolet objectives for bright-field M Plan Apo NUV ............................................................ 3・2 Near-ultraviolet objectives for bright-field (with cover-glass thickness compensation) LCD Plan Apo NUV ....................................................... 3・3 Ultraviolet objectives for bright-field M Plan UV ......................................................................... 3・4 Ultraviolet objectives for bright-field (with cover-glass thickness compensation) LCD Plan UV ..................................................................... 3・5 Tube lens MT ......................................................................................... 3 6 Objectives for measuring microscopes ML ........................................................................................ 3・7 Objectives for centering microscopes CF ........................................................................................... 3 8 Wide field of view eyepieces & reticles WF ......................................................................................... 3 9 Reference: Specifications of Objective Threads/ Transmission of Mitutoyo Objectives ....................... 4・ 0 Commentary: Laser Operating Method and Precautions ............. ・ 41 Glossary ..................................................................................... 4・2
Find out more in our video:
https://bcove.video/3Kp07QU
You can download the CAD data, spectral transmission characteristics, and focal point on the image side data for each product.
For details, please check our website:
5
Microscope unit for incorporating in equipment VMU
VMU-V
VMU-H
VMU-LB
VMU-L4B
Objectives shown mounted on tubes are optional.
Features
Features
> Small, lightweight microscope unit > Compatible with infrared optical systems * 1 > Custom-order is available to meet the customers' requirements * 3
> Can be used with YAG (near-infrared, visible, near-ultraviolet, or ultraviolet) lasers. * 2 (Suitable for cutting, repairing and removing, and processing thin-film) > Models with enhanced rigidity and performance > Custom-order is available to meet the customers' requirements * 3
*1: An infrared source and infrared camera are necessary. *2: The performance and safety of laser-equipped system products is not guaranteed. *3: The design and manufacturing of the VMU series can be adapted to meet the customers’ requirements: differential interference observation, dual camera setup (double magnification: high and low), etc.
Specifications
VMU-V 378-505
VMU-H 378-506 Horizontal
VMU-LB 378-513
VMU-L4B
Model No. Code No.
378-514
Camera mounting orientation
Vertical
Vertical (rotatable)
Observation
Bright-field/erect image
Bright-field/Inverted image
Bright-field/erect image
Magnification: 1X; wavelength ( λ ): visible radiation
Optical features
Camera port
C-mount with centering and parfocal adjustment and green filter switch
Mount
C-mount (centering and parfocal adjustment)
Tube lens (correction range)
Built in 1X (visible - NIR)
Built in 1X (NUV - NIR) Magnification: 1X λ : 355/532/1064 nm
Built in 1X (UV - NIR)
Magnification: 1X λ : 266/355/532/1064 nm
Optical tube
Optical features
YAG laser source (fundamental and second, third and fourth harmonic mode) available
YAG laser source (fundamental, second and third harmonic mode) available
Laser port
—
Mount
With parfocal adjustment
Polarizer unit * 1
Available for observation
Available for observation and laser applications
M Plan Apo, M Plan Apo HR (50X, 100X) M Plan Apo SL, G Plan Apo NIR series
For observation
Suitable objective (optional)
NIR series, NUV series
NIR series, NUV series, UV series
For laser cutting
—
Applicable camera
2/3 inch or smaller
Optical system epi-illumination
Telecentric with aperture diaphragm Bright-field illuminated lens tube
Illuminated lens tube
Fiber illumination unit (LED) ( No.176-386 ) , fiber-optic illumination unit (150 W) ( No.176-316 )
Illumination unit (optional)
Main unit mass
650 g
750 g
1270 g
1300 g
*1: M Plan Apo 1X objective should be used together with a polarizer ( 378-710 or 378-715 ). Note : Observe the following precautions when using VMU-LB or L4B with YAG laser source attached. 1. Be aware of the laser power and energy density. Otherwise, the optical system may be damaged. 2. Check the mass of the laser source. When mounting on a high-speed device or acceleration/deceleration device, please contact us.
6
WIDE VMU-HR
WIDE VMU-BDV
WIDE VMU-BDH
Objectives shown mounted on tubes are optional.
Features
Features
> Observation over a wide field of view (image field of ø30 mm) > Compatible with HR series of high resolving power lens (designed with pupil diameter of ø16.8) > Greatly enhanced brightness on the periphery of the field of view (reduces the dependence on the light distribution characteristics) > Compatible with infrared optical systems * 1 > Small optical observation system (refer to page 9 for the dimensions) *1: An infrared source and infrared camera are necessary.
> Observation over a wide field of view (image field of ø30 mm) > Supports dark-field observation suited to inspection for foreign objects and scratches (instantaneous switching between bright-field and dark-field is possible with illumination light source on/off) > Small design available
Bright-field
Infrared
Dark-field
Specifications
For bright-field observation
For bright/dark-field observation
WIDE VMU-HR
WIDE VMU-BDV
WIDE VMU-BDH
Model No. Code No.
378-519
378-517
378-518 Horizontal
Camera mounting orientation
Vertical
Vertical
Observation
Bright-field/erect image
Bright/dark-field/erect image
Bright/dark-field/inverted image
Optical features Mount
Magnification: 1X Visible light - Near-infrared light
Magnification: 1X Visible light
Camera port
F-Mount, C-Mount (with aligning and parfocal adjustment mechanism)
Optical tube
Imaging forming (tube) lens
Built in 1X (visible - NIR)
Built in 1X (visible)
Image field
ø30 mm
Polarized unit * 1
Mountable
M Plan Apo, M Plan Apo HR, M Plan Apo SL, G Plan Apo, NIR series
BD Plan Apo
Objective lens (required option)
Applicable camera
Diagonal line length: 30 mm or less (equivalent to APS-C format)
Telecentric illumination, bright/dark-field illumination optical tube (Dual-port fiber-optic illumination) Bright/Dark-field switching with light source on-off
Optical system epi-illumination
Telecentric (pupil diameter of ø16.8 with aperture diaphragm)
Bright-field illuminated lens tube (rotatable) * 3 LED adapter and fiber adapter included as standard
Bright-field illuminated lens tube (rotatable) * 3
Illuminated lens tube
Illumination unit (optional) * 2
Fiber illumination unit (LED) ( No.176-386 ), fiber-optic illumination unit (150 W) ( No. 176-316 )
Main unit mass 2150 g *1: Polarized observation by bright-field illumination *2: Support for third-party LED illuminators (WIDE VMU-HR only) *3: The fiber (light source) mount orientation can be changed. 1400 g 2000 g
7
VMU Dimensions
+0.05 +0.1 +0.05 (Compatible with third-party fiber-optic cables) (Compatible with Mitutoyo fiber-optic cable)
ø14
ø14 +0.1
LED Adapter
+0.05
Adapter for Mitutoyo fiber-optic cable
ø10 +0.1
ø8.2
Hexagon socket set screw(M4) for clamping LED light source
LED light source edge position (effective apperture ≧ ø5)
Fiber-optic cable end position
Diagram of LED light source mount
Diagram of fiber mount (VMU)
VMU-V
VMU-H
6.5 6-M4×0.7 screw holes, depth 6 (equal numbers of holes at the same positions on the opposite side) Fiber-optic cable mounting position
59.5 6.5
43.5
3 47
50
80.5
59.5
C mount
Intermediate image position
17.5
63
43.5
50 27
3 47
6-M4×0.7 screw holes, depth 6 (equal numbers of holes at the same positions on the opposite side)
Fiber-optic cable mounting position
C mount
(Emblem)
(Emblem)
27
ø43
ø43
(optional) Objective
(optional) Objective
VMU-LB
VMU-L4B
Intermediate image position
Intermediate image position
Intermediate image position
Intermediate image position
25.07
25.07
ø3
ø3
ø56
ø56
Laser mount
Laser mount
ø50
ø50
Intermediate image position
Intermediate image position
Intermediate image position
Intermediate image position
C mount
C mount
6-M4×0.7 screw holes, depth 6 (equal numbers of holes at the same positions on the opposite side)
66- M- 44××00. 7. 7ssccrreew h o l el ess,, d e p tth 6 (equal numbers of holes at the same positions on the opposite side)
50
50
49.5
49.5
Fiber-optic cable mounting porstitioionn
Fiber-optic cable mounting porstitioionn
3 47
3 47
(Emblem)
(Emblem)
27
27
Objective mount
Objective mount
43.5
43.5
ø43
ø43
(optional) Objective
(optional) Objective
6.5
120
59.5
6.5
120
59.5
Workpiece surface
Workpiece surface
Workpiece surface
Workpiece surface
8
+0.1 +0.05 +0.1 +0.05
ø14 ø10
(Compatible with third-party fiber-optic cables) (Compatible with Mitutoyo fiber-optic cable)
ø14 +0.1
LED Adapter
+0.05
Adapter for Mitutoyo fiber-optic cable
Hexagon socket set screw (M4) for clamping fiber light guide
ø8.2
Hexagon socket set screw(M4) for clamping LED light source
LED light source edge position (effective apperture ≧ ø5)
Fiber-optic cable end position
(Fiber effective diameter of ø5 or greater)
Diagram of LED light source mount
Diagram of fiber mount (WIDE VMU)
WIDE VMU-HR
32
83.5
3 64
60
Image position
F mount
Light souce mounting position
4-M4 × 0.7 depth 6 4-M4 × 0.7 depth 6 (Same position and number on the other side)
64
27
27
(Emblem)
Objective mount
Workpiece surface (Optional) Objective
Workpiece surface
WIDE VMU-BDV
WIDE VMU-BDH
32
146.5
3 64
60
70.5
110
146.5
F mount Intermediate image position Intermediate image position
46.5
63.5
60
70.5
3 64
F mount
4-M4×0.7 screw holes, depth 6 (equal numbers of holes at the same positions on the opposite side)
4-M4×0.7 screw holes, depth 6 (equal numbers of holes at the same positions on the opposite side)
Fiber mounting position (BF)
Fiber mounting position (BF)
Fiber mounting position (DF)
27 64
Fiber mounting position (DF)
27 64
(Emblem)
(Emblem)
(optional) Objective Objective mount
(optional) Objective Objective mount
Workpiece surface
Workpiece surface
Workpiece surface
Workpiece surface
9
VMU System Diagram
VMU
C-mount compatible analog camera or digital camera
Third-party YAG lasers* 5
Fixed-magnification monitoring camera mount ( 378-087 ) P.13* 4
2X TV adapter unit ( 378-703 )
0.5X TV adapter unit * 1 ( 378-704 ) P.13
VMU-V/H ( 378-505/378-506 )
VMU-LB/L4B ( 378-513/378-514 )
Focusing unit A ( 378-705 ) P.13
Focusing unit B* 2 ( 378-706 ) P.13
Polarizer (B) ( 378-715 ) P.13
Simple stand ( 378-730 ) P.25
Manual revolver nosepiece unit (for BF)* 2 ( 378-707 ) ( 378-717 ) P.12 Quad
Polarizer ( 378-710 ) P.13
Self-aligning power revolver nosepiece unit (for BF) * 3 ( 378-713 ) P.12
Transmitted light unit ( 378-736 ) P.25
LED adapter (02AVB662) P.13
Quintuple
LED spot illumination from various manufacturers
Objectives M Plan Apo series (for observation): All types on P.26 to 28 G Plan Apo series (for observation): All types on P.28 NIR series on P.30 to 31 (for fundamental/second harmonic laser machining) (for near-infrared observation) NUV series on P.32 to 33 (for second/third harmonic laser machining) UV series on P.34 to 35 (for second/fourth harmonic laser machining)
Third-party motorized X-Y stages (50×50 mm)* 6
Fiber-optic illumination unit 150 W ( 176-316 )
X-Y stage (50×50 mm) ( 378-020 )
Fiber illumination unit (LED) ( 176-386 )
P.25
P.25
*3: This revolver nosepiece unit cannot be used with focusing unit B ( 378-706 ). For details on mounting position, refer to the figures on page 14. *4: Use this mount when mounting a C-mount camera using the laser port. Use this mount for 2/3-inchor smaller cameras. *5: Mitutoyo does not handle these lasers. Consult Mitutoyo for more information. *6: An adapter may be required when mounting any of these stages. Consult Mitutoyo for more information.
*1: Compatible with 1/2-inch or less C-mount cameras. *2: Use focusing unit B ( 378-706 ) if the distance between the mounting position and VMU main unit isdesired to be as small as possible. If the manual revolver nosepiece unit ( 378- 707 ) is used concurrently, mount the unit in front of the VMU main unit. For details on mounting position, refer to the figures on page 14.
10
WIDE VMU
F-mount compatible analog camera or digital camera
C-mount compatible analog camera or digital camera
C-mount adapter
WIDE VMU-HR ( 378-519 )
WIDE VMU-BDV/BDH ( 378-517/378-518 )
Focusing unit C ( 378-718 ) P.13
Simple stand ( 378-730 ) P.25
Polarizer (C) ( 378-719 ) P.13
4穴 Bright/dark-field revolver ( 378-725 ) P.12
4穴 Bright-field revolver ( 378-724 ) P.12
Bright/dark-field power revolver ( 378-727 ) P.12 Quad
Bright-field power revolver ( 378-726 ) P.12 Quintuple
Transmitted light unit ( 378-736 ) P.25
Objectives
Objectives
BD Plan Apo series (for observation) All types on P.29
M Plan Apo series (for observation) All types on P.26 to 28 G Plan Apo series (for observation) All types on P.28 NIR series on P.30 to 31 (for fundamental/second harmonic laser machining) (for near-infrared observation)
LED adapter (included as standard) P.13
Third-party motorized X-Y stages (50×50 mm)* 1
Fiber illumination unit (LED) ( 176-386 )
Fiber-optic illumination unit 150 W ( 176-316 )
X-Y stage (50×50 mm) ( 378-020 )
P.25
P.25
LED spot illumination from various manufacturers
*1: An adapter may be required when mounting any of these stages. Consult Mitutoyo for more information.
11
Optional Accessories for VMU
Up to 4 objective lenses can be mounted. Manual revolver
No.378-724
No.378-725
Installed on 378-717 VMU-V with optional objectives
Installed on 378-724 WIDE VMU-HR with optional objectives
Bright-field revolver
Bright/dark-field revolver
378-707
378-717
378-724
378-725
Code No.
Observation method
Bright-field
Bright-field
Bright/dark-field
4 (1 reference hole and 3 holes with centering and parfocal adjustment)
4 (reference hole)
4 (reference hole)
No. of objective mounts
4 (reference hole)
Mass
780 g
990 g
825 g
755 g
WIDE VMU-BDV WIDE VMU-BDH
VMU-V, VMU-H, VMU-LB, VMU-L4B
WIDE VMU-HR
Applicable models
Up to 5 objective lenses can be mounted on the bright-field power revolver. Up to 4 objective lenses can be mounted on the bright/dark-field power revolver. Power revolver
No.378-726
No.378-727
Installed on No.378-713 VMU-V with optional objectives
Installed on No.378-726 WIDE VMU-HR with optional objectives
Bright-field power revolver
Bright/dark-field power revolver
378-713
378-726
378-727
Code No.
Observation method No. of objective mounts View field adjustment Positioning accuracy
Bright-field
Bright/Dark-field 4 (Reference hole)
5 (1 reference hole and 4 holes with centering adjustment)
±0.5 mm 2 σ = 3 μm
− − − −
Durability (life-time)
1 million repositioning operations
Drive method
DC motor
AC100 V - 240 V Max. power consumption is approx. 6 W
Power supply
AC100 V - 240 V Max. power consumption is approx. 10 W
Output interface * 1
RS-232C * 1 for external PC control
2.9 m * 2 (connection of power revolver and console box)
Cable length
Revolver: 130x47x186 mm,1.8 kg, Console box: 108x63x176 mm,810 g
Revolver: 164x65x137 mm,1.8 kg, Console box: 108x72x193 mm,810 g WIDE VMU-BDV, WIDE VMU-BDH
Dimensions (WxHxD) and mass
VMU-V, VMU-H, VMU-LB, VMU-L4B
WIDE VMU-HR
Applicable models
*1: Optional RS-232C Cable: 12AAA807 *2: The length of cable connecting the power revolver and console box is a safe maximum and therefore Mitutoyo does not guarantee error-free operation if a cable extension is used to increase total cable length.
12
Focus unit
For manual focusing. With A and C mounted on a simple stand, the stand stage center and optical axis match.
Focus unit A mounted on WIDE VMU-V with an optional objective
Focus unit C mounted on WIDE VMU-HR with an optional objective
Focus unit A
Focus unit B
Focus unit C
378-705
378-706
378-718
Code No.
Travel range
50 mm
Coarse/fine feed Loading capacity
Coarse: 3.8 mm/rev., Fine: 0.1 mm/rev.
Approx. 17.4 kg
Approx. 17.7 kg
Mass
2.9 kg
2.7 kg
VMU-V, VMU-H, VMU-LB, VMU-L4B
WIDE VMU-HR, WIDE VMU-BDV, WIDE VMU-BDH
Applicable models
Provides simplified polarized light observation. Also enhances contrast of low-magnification objectives. Polarizer and analyzer
No.378-719
No.378-710
No.378-715
Polarizer and analyzer
Polarizer and analyzer (C)
378-710
378-715
Code No.
378-719
VMU-V, VMU-H
VMU-LB, VMU-L4B
WIDE VMU-HR, WIDE VMU-BDV, WIDE VMU-BDH
Applicable models
TV adapter unit
C-mount adapters for changing to a higher or lower magnification.
2X TV adapter unit
0.5X TV adapter unit
378-703
378-704
Code No.
Magnification Suitable camera
2X
0.5X
2/3 inch or smaller type
1/2 inch or smaller type
Mass
Approx. 25 g
No.378-703
No.378-704
VMU-V, VMU-H, VMU-LB, VMU-L4B
Applicable models
Camera mount
LED adapter
ø8.2 ø14 +0.1
Can be attached to the laser mount (VMU-LB and VMU-L4B) for dual-camera system.
+0.05
LED Adapter 02AVB662 Approx. 12 g
Hexagon socket set screw(M4) for clamping LED light source
Code No.
Mass
LED light source edge position (effective apperture ≧ ø5)
Camera mount
VMU-V, VMU-H, VMU-LB, VMU-L4B
Applicable models
378-087
Code No.
Suitable camera
2/3 inch or smaller type (C-mount)
*For WIDE VMU, standard accessory.
No. 02AVB662
Mass
Approx. 180 g
VMU-LB, VMU-L4B
Applicable models
No. 378-087
13
Dimensions of Optional Accessories for VMU
Manual revolver
Bright-field revolver (378-707/378-717)
Bright-field revolver (378-724)
MAX 130* MAX 130*
MAX 78* MAX 78*
MAX 130 76.5
MAX 78
76.5 76.5
27
27
27
27
27
Single mount unit
Mount unit Mount unit
Workpiece surface Workpiece surface
Workpiece surface Workpiece surface
* Where M Plan Apo HR100X ( 378-815-4 ) is used * Where M Plan Apo HR100X ( 378-815-4 ) is used
When mounting the revolver on VMU-V or VMU-H Note 1: The lens mount must be removed from VMU. Note 2: The orientation of the revolver can be freely set to the mounting surface.
Note 1: Revolver is installed by removing the single mount unit, but the distance between the mounting position of WIDE VMU main unit and the stage is unchanged. Note 2: Revolver mounting direction is limited to the direction indicated in the figure above.
MAX 77* MAX 77*
MAX 126* 78 MAX 126* 78
Bright/dark-field revolver (378-725)
108 108
MAX 132
MAX 81
27
76.5
27
27
27
27
Intermediate lens tube Intermediate lens tube
Mount unit Mount unit
Single mount unit
Workpiece surface Workpiece surface
Workpiece surface Workpiece surface
* Where M Plan Apo NIR HR100X ( 378-864-5 ) is used * Where M Plan Apo NIR HR100X ( 378-864-5 ) is used
When mounting the revolver on VMU-LB or VMU-L4B Note 1: The middle optical tube and lens mount must be removed from VMU. Note 2: The orientation of the revolver can be freely set to the mounting surface.
Note 1: Revolver is installed by removing the single mount unit, but the distance between the mounting position of WIDE VMU main unit and the stage is unchanged. Note 2: Revolver mounting direction is limited to the direction indicated in the figure above.
Power revolver
Bright-field power revolver (378-713)
Bright-field power revolver (378-726)
MAX 130 87
MAX 78
27
M20×0.5
27
Single mount unit
Workpiece surface Workpiece surface
88.6 88.6
136
87
Workpiece surface Workpiece surface
MAX130*
MAX78*
Note 1: Revolver is installed by removing the single mount unit, but the distance between the mounting position of WIDE VMU main unit and the stage is unchanged. Note 2: Revolver mounting direction is limited to the direction indicated in the figure above.
* Where M Plan Apo HR100X ( 378-815-4 ) is used * Where ( 378-815-4 ) is used
When mounting the revolver on VMU-V or VMU-H Note 1: The lens mount must be removed from VMU. Note 2: The orientation of the revolver can be freely set to the mounting surface.
Bright/dark-field power revolver (378-727)
MAX 132
MAX 80
88
27
27
M20×0.5
27
Mount unit Mount unit Intermediate lens tube Intermediate lens tube
Workpiece surface Workpiece surface
Single mount unit
Workpiece surface Workpiece surface
88.6 88.6
136
87
MAX126*
MAX77*
* Where M Plan Apo NIR HR100X ( 378-864-5 ) is used * Where ( 378-864-5 ) is used
When mounting the revolver on VMU-LB or VMU-L4B Note 1: The middle optical tube and lens mount must be removed from VMU. Note 2: The orientation of the revolver can be freely set to the mounting surface.
Note 1: Revolver is installed by removing the single mount unit, but the distance between the mounting position of WIDE VMU main unit and the stage is unchanged. Note 2: Revolver mounting direction is limited to the direction indicated in the figure above.
14
Focus unit
Hole positions for mounting onto the main unit
(37)
117
(37)
117
5-M4 screw holes, depth 8
Vertical travel
63.5 229
5-M4 screw holes, depth 8
63.5 229
63.5 94 102
23.5
56.5
73 1
(4)
80
Focusing unit A
73
1
32 48 80
63.5 94 102
(37)
87.6
Hole positions for mounting onto the main unit
(4)
5-M4 screw holes, depth 8
Vertical travel
229 63.5
Focusing unit C
63.5 102 94
23.5
26.5
73 1
(4)
50
Focusing unit B
Polarizer and analyzer
Polarizer and analyzer (C)
28
Vertical illumination unit with aperture diaphragm
5
Main body
Camera lens tube
Analyzer
Analyzer
Illuminated lens tube
Analyzer
Illuminated lens tube
30
6
Cover ring
Polarizer
Polarizer
Polarizer
Workpiece surface
Installing the polarizer and analyzer on VMU-V or VMU-H Note: The analyzer is installed by removing the Illuminated lens tube. The polarizer is installed by removing the vertical illumination unit with aperture diaphragm.
Note: The polarizer is installed by loosening the cover ring.
The analyzer is installed by removing the camera lens tube.
Vertical illumination tube with aperture diaphragm
Analyzer
Cover ring
Polarizer
When installing the polarizer on VMU-LB or VMU-L4B Note: The analyzer is installed by loosening the cover ring. The polarizer is installed by removing the vertical illumination unit with aperture diaphragm.
TV adapter unit
Camera mount
LED adapter
ø8.2 ø14 +0.1
75
Intermediate image position C mount 2X adapter lens unit
Intermediate image position C mount 0.5X adapter lens unit
+0.05
Intermediate image position
Hexagon socket set screw(M4) for clamping LED light source
LED light source edge position (effective apperture ≧ ø5)
ø56 0 +0.05 ø38
Dimensions with the 2X TV adapter unit mounted
Dimensions with the 0.5X TV adapter unit mounted
15
White Light Interference optical Unit WLI-Unit
Objectives shown mounted on tubes are optional.
>Non-contact high-accuracy fine surface texture measurement is possible through white light interference: 3D shape measurement, 3D roughness measurement. > Height measurement accuracy not dependent on optical magnification Measurement enabled with high Z-resolution even with low-magnification lens > High aspect ratio measurement Supports high aspect ratio shape measurement through detection not dependent on optical-based NA > High robustness with regard to disturbance vibration > Compact and lightweight Features
Specifications
554-001
554-002
554-003
Code No.
Model
WLI-Unit-003
WLI-Unit-005
WLI-Unit-010
Cable length (m)
3
5
10
Applicable objective lens *Optional selection Tube lens magnification Focal range (f mm) Scanning mechanism
WLI Plan Apo series
1X
WLI-Unit Sensor Head
100
Mitutoyo Objective Lens Scanner
Size/weight
108x68x191 mm / 1.7 kg
Z motion range
8000 µm Standard 1900 µm
Measurement mode
High throughput
High resolution
WLI measurement (WLI-Unit-003/005/010 common)
WLI measurement Z range Throughput @20 μm range
2100 µm
1700 µm
3.0 s
4.0 s
6.0 s
Z resolution
− −
4 nm
Z repeatability ( σ )
40 nm
I/F
WLI-Unit sensor head terminal/stop connector/GigaBit Ethernet: 2 ch
AC100 ~ 240 V / 50, 60 Hz
Rated voltage
WLI-Unit Controller
Max. power consumption
20 W
Size/weight
196x180x108 mm / 2.3 kg
WLIPAK
WLI-Unit control library (SDK), sample code, WLIPAK Sample GUI
Software
WLI-Unit calibration SW
Pixel calibration
Analysis software (recommended option)
MCubeMap
Other
Frame grabber/PC
Matrox frame grabber/PC separate
Recommended PC specifications OS: Windows 10 Pro 64 bit/Windows 11 Pro 64 bit, CPU: Xeon Processor 8 Core (2.0 GHz or above), memory: 8 GB or above, storage: 25 GB or above, optical drive: DVD-ROM drive (for software installa - tion), communication port: RJ-45 × 1 port (EtherNET), extension slots: PCI Express 3.0 × 8 or above
16
Objective lens for white light interference measurement WLI Plan Apo
WLI-Unit
Scheduled for autumn 2024 release
Features
> New design matching the WLI-Unit > Ensures long working distance while more compact and lighter-weight (parfocal 60 mm) > High NA, high resolution > Plan apochromat
> Beam splitter and reference mirror mounted inside objective lens > Interference fringe adjustment mechanism equipped as standard
Dimensions
WLI Plan Apo 2.5X
WLI Plan Apo 5X
WLI Plan Apo 10X
WLI Plan Apo 25X
WLI Plan Apo 50X
ø40
ø40
ø40
ø40
58.5
M20.32/36 山
M20.32/36 山
M20.32/36 山
M20.32/36 山
ø35
22.1
ø38
ø38
ø38
ø38
Lens specifications
Mirror tube length
FOV (mm)
Applicable tube lens f (mm)
Parfocalizing distance (mm)
Mass (g)
W.D. (mm)
Model Code No.
Outermost diameter Mounting screws
f (mm)
N.A.
R (µm)
2/3 inch camera
(excluding mounting screws)
WLI-Unit
WLI Plan Apo
36.4 ( excluding interference unit ) 58.5 ( Max )
WLI Plan Apo 2.5X 378-400
0.14
13.0
40
2.0
60
2.94×2.25 2.64×3.52
100
47
320
WLI Plan Apo 5X 378-005 WLI Plan Apo 10X 378-401 WLI Plan Apo 25X 378-402 WLI Plan Apo 50X 378-403
0.28
8.0
20
0.98
60
1.46×1.12
1.32×1.76
100
52
40
210
RMS / 20.32 mm ×36 TP
0.38
6.0
10
0.72
60
0.73×0.56 0.66×0.88
100
54
40
220
0.50
3.6
4
0.55
60
0.29×0.22 0.26×0.35
100
57
40
290
0.70
2.0
2
0.39
60
0.14×0.11
0.13×0.18
100
58
40
300
•Resolution values in the specifications above are calculated based on reference wavelength ( λ = 0.55 μm).
17
WLI Measurement Example
Roughness specimen 3 μm
Semiconductor test pattern (TEG)
Provided by Walts Co., Ltd. and ASK INDEX
Cu pattern (glass substrate)
Metal machined surface (Aluminum)
18
WLI System Configuration ( example with stand/motorized stage/vibration isolation table )
Stand*
PC
WLI-Unit Sensor Head
WLIPAK SampleGUI Implements WLI measurement
MCubeMap Implements analyses
WLI-Unit Controller
*Image is for illustration purposes
Ex.: 3D display
Vibration Isolation table*
*Stand and vibration isolation table are recommended products
Dimensions
WLI-Unit Sensor Head
WLI-Unit Controller
108
45
196
Mounting screws 2×1/4 depth 6
Guide pin holes Depth 4
45
2
+0.01 0
Mounting screws 2×1/4 depth 6
Guide pin holes Depth 4
45
2 +0.01 0 Back mounting part
19
Microscope unit FS70
FS70Z
FS70L
FS70L4
The eyepieces, revolver and objectives shown mounted are optional.
Features
> Product range supporting various observation methods (Bright-field/dark-field/simple polarization/differential interference contrast (DIC)) > Equipped as standard with a Koehler illumination with aperture diaphragm for epi-illumination optical systems > High operability with microscopes (Inward revolver design and long-working-distance objectives) *1 : The performance and safety of laser-equipped system products is not guaranteed. *2: An infrared source and infrared camera are necessary. For more details on infrared observation, contact your local Mitutoyo sales office.
> Compact microscope unit with trinocular eyepiece tube (Suitable for observation of many different types of object: metal surfaces, semiconductors, LCDs, resins, etc.) > Can used with YAG (near-infrared, visible, near-ultraviolet, or ultraviolet) lasers. *¹ (Suitable for cutting, trimming, repair and marking of IC wiring (Au, Al), removing and processing thin-films (insulating film) and repair of color filters). > Compatible with infrared optical systems *²
SF70 dimensions
27.2
27.2
27.2
324
324
324
154
154
154
324
324
324
324
324
324
154
154
154
Intermediate image position
154
Intermediate image position
Intermediate image position
154
154
Laser mount Vertical travel
Laser mount Vertical travel
ø38 Intermediate image position
ø38 Intermediate image position
ø38 Intermediate image position
Intermediate image position
Intermediate image position
Intermediate image position
25 25 Vertical travel ø38
Laser mount Vertical travel
Laser mount Vertical travel
Laser moun Vertical trave
Laser mount Vertical travel
25 25
ø38
25 25
ø38
ø38
25 25 Vertical travel
ø38
ø38
25 25 Vertical travel
25 25
25 25
25 25
25 25
Objective mounting surface
Objective mounting surface
Objective mounting surface
Objective mounting surface
Objective mounting surface
Objective mounting surface
Objective mounting surface
Objective mounting surface
Objective mounting surface
MAX 78
MAX130
MAX 78
MAX 78
MAX130
MAX130
153 (Mounting surface)
153 (Mounting surface)
1 MAX130
153 (Mounting surface)
MAX 78
1
1 MAX130
MAX 78
MAX 78
MAX130
MAX 78 154
MAX130
MAX 78 154
MAX 78 154
MAX130
MAX130
153 (Mounting surface)
153 (Mounting surface)
1
153 (Mounting surface)
1
153 (Mounting surface)
1
153 (Mounting surface)
153 (Mounting surface)
1
1
154
154
154
154
154
154
FS70Z(FS70ZD)
FS70L
FS70L4
ø7.5 ø10 +0.1
+0.05
ø7.5 ø10 +0.1
ø7.5 ø10 +0.1
Fiber-optic cable end position +0.05
4-M4 screw holes, depth 8
+0.05
Fiber-optic cable end position
4-M4 screw holes, depth 8
Fiber-optic cable end position
4-M4 screw holes, depth 8
63.5 94
63.5 94
63.5 94
Back of standard focus unit (for all models)
Detail of fiber mount (for all models)
20
Specifications
FS70
FS70Z
FS70ZD
FS70L
FS70L4
— —
— —
Model No. Code No. Model No. Code No.
Standard head type
378-184-1
378-185-1
378-186-1 FS70L-TH 378-186-3
378-187-1 FS70L4-TH 378-187-3
Made-to-order FS70ZD-TH Made-to-order
FS70-TH 378-184-3
FS70Z-TH 378-185-3
— —
— —
Tilting head type
Erect image
BF (Bright-field) BD (Bright-field/ Dark-field) Polarization Differential interference contrast (DIC)
✔
✔
✔
✔
✔
✔
✔
Observation image
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
10X (field number 24) · 15X (field number 16) · 20X (field number 12)
Eyepieces (required option)
Field number Eye width adjustment
24
Siedentopf, adjustable interpupillary distance range: 51 - 76 mm
Tilt angle
0 to 20° (only for -TH), displacement of eye point: approx.114 mm
Fixed type (Eyepiece/TV = 50/50)
Switchable type (Eyepiece/Tube = 100/0: 0/100)
Fixed type (Eyepiece/TV = 50/50)
Switchable type (Eyepiece/Tube = 100/0: 0/100)
Fixed type *¹ (Eyepiece/TV = 50/50)
Switchable type (Eyepiece/Tube = 100/0: 0/100)
Optical pass ratio
Trinocu - lar tube
C-mount receptacle (with green filter switch) (with parfocal adjust - ment)
Camera port Mount
C-mount (using optional adapter B*²) Parfocal adjustment with adapter B
Use a laser with TV port.
Optical tube
Protective filter
—
Built-in laser beam filter
1X
Tube lens
1X
1X-2X zoom
Magnification: 1X λ : 355/532/1064 nm YAG laser source (fundamental, second and third harmonic mode) available
Magnification: 1X λ : 266/532 nm YAG laser source (second, fourth harmonic mode) available
Optical features
Laser port
—
Mount
Coarse and fine movement
Micro- scope head
Uniaxial coarse and fine movement (Coarse: 3.8 mm/rev. fine 0.1 mm/rev.)
Movement
50 mm, left and right handle
Optical system epi-illumination
Epi-illumination for bright-field (Koehler illumination, with aperture diaphragm)
Fiber illumination unit (LED) ( No.176-386 ), 150 W fiber-optic illumination unit ( No.176-316 ) stepless adjustment, light guide length: 1500 mm
Illumination unit (optional)
Manual revolver nosepiece unit quad / Power revolver nosepiece unit quad
Self-aligning manual revolver nosepiece unit quad / self-aligning power revolver nosepiece unit quintuple
Self-aligning manual revolver nosepiece unit quad / Self-aligning Power revolver nosepiece unit quintuple
Revolver (required option)
M Plan Apo M Plan Apo HR M Plan Apo SL G Plan Apo
M Plan Apo M Plan Apo HR M Plan Apo SL G Plan Apo
BD Plan Apo
For observation
Suitable objective (required option)
NIR Series NUV Series *Select from wavelengths used by laser source 14.1 kg (tilting headtype: 13.2 kg)
UV Series
For laser cutting
—
14.2 kg (tilting headtype: 13.5 kg)
13.9 kg (tilting headtype: 13.1 kg)
Loading * 3
14.5 kg
13.6 kg
14.1 kg
13.2 kg
Dimensions
Refer to P.20
6.6 kg (tilting headtype: 7.5 kg)
6.4 kg (tilting head type: 7.2 kg)
6.7 kg (tilting head type: 7.5 kg)
Mass (main unit)
6.1 kg
7.1 kg
6.6 kg
7.5 kg
*1: It is a switchable type when using FS70ZD-TH (Tilting head type). *2: Installation is optional. *3: Loading on optical tube excluding weight of revolvers, objective lenses and eyepieces. Note: When using the objective M Plan Apo 1X, using this lense with a differential interference contrast unit (No.378-092 or 378-094) is recommended.
Note: Observe the following precautions when using FS70L or FS70L4 with YAG laser source attached. · Be aware of the laser power and energy density limitations of the optical system to avoid damaged. · Check the mass of the laser source. When mounting on a high-speed device or acceleration/deceleration device, please contact us.
21
System diagram
C-mount compatible analog camera or digital camera
Third-party YAG lasers* 1
Differential interference contrast unit ( 378-076 , 378-078 , 378-079 , 378-080 ) P.23
0.5X TV adapter unit ( 375-054 ) P.23
Polarizer (C) ( 378-094 ) P.23
Eyepieces P.39 WF10X/24 ( 378-866 ) WF20X/12 ( 378-858 )
Polarizer (A) ( 378-092 ) P.23
Adapter B ( 378-042 ) P.23
FS70 ( 378-184-1 )
FS70ZD
FS70Z ( 378-185-1 )
FS70L ( 378-186-1 )
FS70L4 ( 378-187-1 )
FS70Z-TH ( 378-185-3 )
FS70-TH ( 378-184-3 )
FS70ZD-TH
FS70L-TH ( 378-186-3 )
FS70L4-TH ( 378-187-3 )
Simple stand ( 378-730 ) P.25
Manual revolver nosepiece unit (for BF/DF) ( 176-211 ) P.23 Quad
Self-aligning manual revolver nosepiece unit (for BF) ( 378-018 ) P.23 Quad
Self-aligning Power revolver nosepiece unit (for BF) Quad ( 378-016 ) Quintuple ( 378-216 ) P.23
Power revolver nosepiece unit (for BF/DF) ( 176-212 ) P.23
Quad
Quintuple
Transmitted light unit ( 378-736 ) P.25
Objectives M Plan Apo series (for observation): P.26 to 28 G Plan Apo series (for observation): P.28 NIR series on P.30 to 31 (for fundamental/second harmonic laser machining) (for near-infrared observation) NUV series on P.32 to 33 (for second/third harmonic laser machining) UV series on P.34 to 35 (for second/fourth harmonic laser machining)
Fiber-optic illumination unit 150 W ( 176-316 ) P.25
Fiber illumination unit (LED) ( 176-386 )
P.25
Fiber-optic illumination unit 150 W ( 176-316 ) P.25
Fiber illumination unit (LED) ( 176-386 )
Objectives BD Plan Apo series (for observation): P.29
P.25
X-Y stage (50×50 mm) ( 378-020 )
Third-party motorized X-Y stages (50 × 50 mm) * 2
*1: Mitutoyo does not handle these lasers. Consult Mitutoyo for more information. *2: An adapter may separately be required when mounting any of these stages. Consult Mitutoyo for more information.
P.25
22
Optional Accessories for FS70
Manual revolver
Power revolver
Console box
378-016
Code No.
Code No.
378-018
176-211
378-216
378-016
176-212
Observation method
Bright-field
Bright /Dark-field
Observation method
Bright-field
Bright /Dark-field
4 (1 reference hole and 3 holes with centering and parfocal adjustment)
5 (1 reference hole and 4 holes with centering adjustment)
4 (1 reference hole and 3 holes with centering adjustment)
No.of objective mounts
4
No. of objective mounts
4
View field adjustment Parfocal adjustment
±0.5 mm ±0.5 mm
— —
View field adjustment Positioning accuracy
±0.5 mm
— —
2 σ = 3 μm
—
Mass
980 g
1.2 kg
1 million repositioning operations
Durability (life-time)
—
—
Polarizer and analyzer
Drive method Power supply
DC motor
AC100 V - 240 V, 10 W
AC100 V - 240 V, 6 W
For simplified polarized-light observation. Also suitable for enhancing contrast of low-magnification objectives.
RS-232C* 1 for external PC control
Output interface
2.9 m* 2 (connection of power revolver and console box)
Cable length
Revolver: 164x65x137 mm, 1.4 kg ( 378-216 : 130x47x186 mm, 1.7 kg) Console box: 108x72x193 mm, 810 g ( 378-216 : 108x63x176 mm, 810 g)
Dimensions (WxHxD) and mass
For FS70L • FS70L4 378-094
For FS70Z 378-092
*1: Optional RS-232C Cable: 12AAA807 *2: The length of cable connecting the power revolver and console box is a safe maximum and therefore Mitutoyo does not guarantee error-free operation if a cable extension is used to increase total cable length.
DIC unit
Used for differential interference contrast observation in conjunction with the polarizer.
Code No. 378-076 378-078 378-079 378-080
Magnification
100X, SL80X, SL50X
50X, SL20X
20X
10X, 5X
Adapter B
Allows observation over a wide field of view on the monitor (2X wide) due to the 0.5X relay optics. It is used in conjunction with the optional adapter B. A C-mount is included. 0.5X TV adapter unit
Used for mounting a C-mount camera.
ø45
Intermediate image position
23
ø45
+0.05 0
ø38
ø54
74.1
375-054 View field of image: ø11 mm Mass: 300 g
378-042 View field of image: ø11 mm Mass: 170 g
23
Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42 Page 43 Page 44Made with FlippingBook. PDF to flipbook with ease