Hot Runner & Control Systems

HOT RUNNER & CONTROL SYSTEMS

Table of Contents Hot Runner Systems

Hot Runner Systems

Temperature Control Systems SS TSP & TSP Plus.

Stellar Micromolding...................................................29-32 Thermal Gate Hot Runner Systems. Hot Runner Systems Stellar One Hot Runner Systems..........................20-27 Customer Commitment........................................................4. Terms and Conditions of Sale ............................................5. Sales and Ordering Information ........................................6. Hot Runner Warranty ..........................................................7. Hot Runner Systems Overview...................................... 8-9 Custom Applications Engineered Hot Runner Systems . Hot Runner Selection Guide.............................................11. Standard Global Manifold and Components .................1 3. Plastic Materials, Specs/Bushing Selection........... 13-14. Hot Runner Quote Request Form.....................................15. DME Hot Runner Technology...........................................18

Smart Series ®

I TSP Plus (Touch Screen Panel............................11 4 -11 8 Typical System Configurations......................................12 4 Single Zone Controllers...........................................125-127 2-zone Controllers............................................................127 Single & 2-zone Accessories.................................128-129 Single Zone High Power Controller & Accessories...130 Smart Series 15 AMP Mainframe Configurations...........................................................131-132 Floor Stand........................................................................135 Step-Down Transformer Kits..........................................135 Blank Panels, Fuses & Crimp Connectors...................135 Mainframe Connector Wiring.................................136-138 Mold Power & Thermocouple Cables..........................139 Mold Power Input Connectors.......................................140 Mold Thermocouple Connectors...................................141 Mold Connector Pocket Layouts............................142-143 Pre-wired Combination Terminal Mounting Boxes....144 Terminal Mounting Boxes...............................................145 SSM Modules............................................................146-147 TSM Modules............................................................148-149 TAS Temperature Alarm/System Modules...........150-151 Replacement Parts...................................................152-154 Input Wiring Diagram..............................................155-157 Alternate Cable Configurations..............................158-161 Smart Series Me Temperature Controllers ..........162 -163 Smart Series M2+ Temperature Controllers........ 164-166 Smart Series Mt2 Temperature Controllers .........167-168 Valve Gate Controller Products & Solutions SVG Valve Gate Controllers......... ........................... 170-173 VCAP Air Valve Assemblies...........................................1 74 Single Zone Timer............................................ . ................169 Technical Support................................. . ................... 176-177 Valve Gate Cables ...........................................................1 74

Standard Pre-Engineered Hot Runner Systems

The Hot One Technology.............................................34-52. Meteor Hot Runner......................................................51-60

Hot Sprue Bushings D-MAX............................................................................64-69 Gate-Mate .....................................................................71-77 Straight Shot ® ................................................................79-88 >High-Performance........................79-80 >S-Series ..............................................81 >E-Series .........................................82-83 >ER-Series ......................................84-85 >T-Series ..............................................86 >TR-Series ...........................................87 >Replacement Parts ..........................88 Integrally Heated Sprue Bushings ...........................89-94.

Hot Runner Services.

Obsolete System Replacement Parts Gate-Mate...................................................................102-103 Cool One......................................................................104-111 Moldflow..........................................................................96-97 Moldflow Quote Request Form.........................................98 Hot Runner Service Center.........................................99-100

Modular Components Deliver High Performance......112

U.S. 800-626-6653

n Canada 800-387-6600 n

dme.net

store.dme.net

n

Hot Runner Systems

3

3

Index

Alternate Cable Configuration..............................................159 Alternate Cable Wiring Diagram..........................................160 Blank Panels, Fuses & Crimp Connectors.............................135 Bushing Selection....................................................................14

Obsolete Hot Runner Replacement Parts.............................101 Cool One & Micro Cool One............................................104 Gate-Mate Nozzles...........................................................102 Gate Shell Insulators........................................................103

Replacement Parts (Temp Control)........................................152

Cartridge Heaters....................................................................47. Control Systems.............................................................. ...... 1 14

Sales and Ordering Information................................................6 Selection Guide, Hot Runner Technology...............................10 Single & 2-Zone Controller Accessories........................125-130 Single Zone Controllers.........................................................125 Single Zone High Power Controller & Accessories..............130 Single Zone Timer..................................................................169. StellarO NE Hot Runner System ............................... ...... 20-27... Smart Series Me Temperature Controllers...........................162 Smart Series M2+ Temperature Controllers.........................162 Smart Series Mt2 Temperature Controllers.......................... 1 67 SSM15 AMP Mainframe Modules.......................................146. Stellar Micromolding Hot Runner Systems............................ 28 Step-Down Transformer Kit...................................................135 Straight Shot™ Hot Sprue Bushings.......................................78. TAS Temperature Alarm/System Modules.......................... 150 Technical Support Data (Temp Control)................................170 Terminal Mounting Boxes.............................................145, 161 Terms and Conditions of Sale...................................................5 Thermocouple Cables............................................................139 Thermocouple Input Connectors...........................................140 TSM Modules........................................................................148. TSP Plus Temperature Controllers.........................................118 Tubular Heaters, Flexible.........................................................41. Two Zone (2-Zone) Temperature Controllers ........................ 127. Typical System Configuration (Temp Control) ...................... 124 VCAP Air Valve Accessories..................................................168. Valve Gate Controls .............................................................. 164 Valve Gate Single Zone Timer................................................169

D-MAX High Performance Hot Sprue Bushings.....................63 Digital Current/Voltage Monitor...........................................134.

Flexible Tubular Heaters ......................................................... 41 Floor Stand (Temp Control)....................................................135 Gate-Mate Hot Sprue Bushings..............................................71. Global Manifolds .................................................................... 1 3 Hot One Components & Accessories......................................35 Hot One Hot Runner Technology – Overview.........................18 Hot Runner Modular Components........................................112 Hot Runner Quote Request Form.........................................15 Hot Runner Services................................................................96 Hot Runner Selection Guide....................................................10 Hot Runner Warranty................................................................7 Hot Sprue Bushings, D-MAX High Performance....................64. Hot Sprue Bushings, E-Series Straight Shot ® ..........................82. Hot Sprue Bushings, ER-Series Straight Shot ® ........................84 Hot Sprue Bushings, High-Performance.................................79 Hot Sprue Bushings, Integrally Heated...................................89. Hot Sprue Bushings, Straight Shot ® Replacement ..................88. Hot Sprue Bushings, S-Series Straight Shot. ® .........................81. Hot Sprue Bushings, Straight Shot. ® .................................... ... 78. Hot Sprue Bushings, T-Series Straight Shot ® ..........................86 Hot Sprue Bushings, TR-Series Straight Shot. ® . ......................87 Input Power Wiring Diagrams...............................................155 Integrally Heated Hot Sprue Bushings....................................89 Mainframe Connector Wiring...............................................136 Meteor Hot Runner Systems...................................................53 Moldflow™ Services...............................................................96 Mold Connector Pocket Layouts...........................................142 Mold Filling/Mold Cooling Analysis Form...........................98 Mold Power Cables...............................................................139 Mold Power Input Connectors..............................................140 Mold Thermocouple Connectors...........................................141 Pre-Wired Combination Terminal Mounting Boxes..............144 Plastic Materials and Specifications......................................13

Warranty Information................................................................7

U.S. 800-626-6653 • Canada 800-387-6600 • dme.net • store.dme.net

4

4

Customer Commitment Hot Runner Systems

Application Engineering

Is there a hot runner application on your wish list that you don’t see here? DME can help. Our design and applications engineering group consists of professional engineers and experienced designers. Once you provide the information necessary for proper application design and analysis, the DME applications engineering team will go to work diligently analyzing, designing and manufacturing a hot runner system that will best suit your needs and requirements.

To take advantage of any or all of these services, or if you have any questions, problems, or ideas please call DME at: n 800-626-6653 (U.S.) n 800-387-6600 (Canada) Part prints or system design prints may be sent in the following ways:

n dme_appl_eng@dme.net n 248-544-5707 (U.S.) fax n 905-677-5280 (Canada) fax

Technical Service

DME is proud to say that it is an industry model for technical service coverage and response. The DME technical service department covers the entire United States and Canada, with additional service representatives in Europe, Asia and throughout the world. Because DME knows you need assistance starting, operating, and maintaining hot runner systems it has made a great effort to strategically staff a Technical Service Department that is responsible for the success of DME’s molding systems. When you need a knowledgeable person to help you order parts and components, DME has you covered. Our direct field sales force puts a local sales representative in your area. One who understands your business and can offer valuable assistance in helping you select the molding system best suited to your application and your budget. In addition, DME provides a customer service department that has been extensively trained on all of DME’s products and systems, making it easier for you to order and have your questions answered. We can provide you price and delivery information on all DME items quickly and accurately. Field Sales and Customer Service

DME offers you a wide range of services from component selection to on-site system installation. Our ever-growing list of services include the ability to:  n Analyze the best system to fit your needs n Assist in system design n Perform computerized system analysis and resin qualification before any metal is cut  n Marry your system to the mold base, plates and components required  n Provide quotations for and perform all of the special machining required n Assemble and wire the system  n Check mechanical fit of all components and perform electrical load testing n Assist with system start-up and maintenance All of which gives you ... more time to concentrate on cavities and cores!

U.S. 800-626-6653 • Canada 800-387-6600 • dme.net • store.dme.net

Terms and Conditions of Sale Hot Runner Systems

5

5

DME COMPANY LLC (“SELLER”) TERMS AND CONDITIONS OF SALE

1. ACCEPTANCE OF TERMS: Seller’s offer is expressly conditioned upon Buyer’s acceptance of these Terms and Conditions, and Seller expressly objects to any ad- ditional or different terms proposed by Buyer. Any subsequent purchase order issued by Buyer shall constitute Buyer’s agreement to these Terms and Conditions. Any contrary terms and conditions contained in any purchase order, facility entry form, or other instrument issued by the Buyer are expressly rejected and shall not apply to this transaction. Unless otherwise specified in the quotation, Seller’s quotation shall expire 30 days from its date and may be modified or withdrawn by Seller before receipt of Buyer’s conforming purchase order. 2. PAYMENT TERMS: Payment is due in accordance with any applicable progress, advance or other agreed upon payment schedule, or, if no such schedule has been agreed to, no later than 30 days from the date of invoice. Buyer shall pay a late payment charge computed at the lower of 1.5% per month on any overdue balance, or the maximum rate permitted by law. No cash discount is provided. If at any time Seller reasonably determines that Buyer’s financial condition or payment history does not justify continuation of Seller’s performance, Seller shall be entitled to require full or partial payment in advance or otherwise restructure payments, request additional forms of payment security, suspend its performance or terminate the order. 3. DELIVERY 3.1 In the United States, products are sold FCA Incoterms 2020 point of origin; for export sales, terms are FCA Incoterms port of export. Unless otherwise agreed in writing, title and risk of loss shall pass at the time of shipment. Buyer is responsible for all taxes, duties, fees, or other governmental charges related to its purchase of goods, with the sole exception of taxes on Seller’s income. Unless otherwise agreed, Buyer shall pay all packing and delivery costs. 3.2. Seller’s quoted lead times and targeted delivery dates are good faith estimates and are not binding on Seller. Buyer’s acceptance of delivery of Seller’s products from the carrier shall constitute a waiver of any claim for delay. If Seller notifies Buyer that the products are ready for shipment and Buyer delays delivery, then Seller may charge Buyer a storage fee equal to 1.5% of the contract price per month for each month of delay. Such storage fees are in addition to any other remedies Seller may have. 3.3. Buyer shall have a reasonable opportunity to inspect any products prior to ship- ment. Products shall be deemed to be accepted upon the earlier of: (i) inspection at Seller’s plant (provided that no reasonable objection is then raised by Buyer), or (ii) if no inspection is requested, then at shipment. If an objection is made during inspection, then Products shall be deemed accepted upon resolution of the objection by Seller. 4. WARRANTY: 4.1. Seller’s express product warranty be as stated in DME’s order specification documentation and shall run from the date of shipment (the “Warranty Period”). During the Warranty Period, Seller warrants that the products and services sold hereunder will be free from material defects in material, workmanship and title (the “Warranty”). 4.2. If, during the Warranty Period, Seller reasonably determines that the products do not meet the Warranty, then Seller shall, at its option, repair or replace the defective product or component thereof, reperform any defective services at Seller’s expense, or refund or credit to Buyer its purchase price for the defective products or services. 4.3. The Warranty will be void and will not apply: (i) when Buyer fails to promptly notify Seller of any alleged defect, (ii) when Buyer fails to properly install, maintain, or operate the products, (iii) to any product or parts thereof with a useful life, under normal operating conditions, inherently shorter than 1 month, or (iv) to products which were not made by Seller or any of Seller’s affiliates, provided that in such cases Seller shall use reasonable efforts to pass on to Buyer the manufacturer’s warranty. 4.4. If Seller provides any parts or services to repair a product that is not under War- ranty, then such parts and services will be billed to Buyer at Seller’s prevailing rates for time and materials. 4.5. The Warranty set out above is the sole and exclusive warranty provided by Seller for its products and is in lieu of, and Seller expressly disclaims, all other war- ranties, express or implied, oral, written or statutory. THERE ARE NO WARRANTIES OF MERCHANTABILITY OR FITNESS FOR PURPOSE FOR SELLER’S PRODUCTS. 5. LIMITATION OF LIABILITIES: 5.1. Seller’s total liability to Buyer arising out of or resulting from this Contract or related in any way to Seller’s products or parts thereof shall not exceed the contract price for such products. 5.2. Seller shall not be liable for loss of profit or revenues, loss of use of products, interruption of business, downtime costs, increased operating costs, or any special, consequential, incidental indirect or punitive damages, whether incurred by Buyer or Buyer’s customers. 5.3. Because the conditions of actual production in each end user’s plant vary con-

siderably, Buyer assumes all risk for the results obtained by use of Seller’s products in the practice of any process, whether in terms of operating costs, general effectiveness, success or failure, and regardless of any oral or written statements made by Seller related to the use of its products. 6. SECURITY INTEREST. Buyer agrees that the Seller shall have and retain a purchase money security interest in the Products securing the payment of all sums becoming due hereunder. Such security interest shall attach, upon completion of manufacture, to the Products and to any parts or accessories attached to the Products and to the proceeds of any sale thereof. Buyer represents that the Products are being acquired for use in its business and that such Products will not, without prior written consent of the Seller, be sold or removed from the Buyer’s place of business to which delivery is made. Buyer agrees upon Seller’s request to execute any financing statements or other documents required to perfect, continue or renew Seller’s security interest in the Products. 7. CANCELLATION: Unless otherwise agreed, Buyer may cancel all or any part of the order by written notice received by Seller before the completion of the order. On receipt of such cancellation notice, all work on the order or part thereof canceled will be stopped as promptly as is reasonably possible. Buyer will then be invoiced for and will pay to Seller as liquidated damages a cancellation charge. For completed items, the charge will be equal to their established prices. For items not completed, the charge will be equal to 135% of Seller’s full cost as determined by Seller in accordance with Seller’s standard accounting practices (which includes burden and overhead), plus a charge for any packing and storage, less a credit for the balance of the material as scrap. 8. RETURNS: All returned items require a Return Merchandise Authorization (RMA) number from DME. Returns are subject to a quality inspection to validate whether it can be returned to inventory. Mold bases, plates, special components, made-to-order products and other date-sensitive products are non-returnable items. Items returned to DME without prior authorization(RMA)may be returned to sender. Items returned for stated defect or non- conforming reason require detailed explanation. No products are returnable beyond 30 days after receipt. 9. CONFIDENTIALITY. Any nonpublic information, including without limitation, Seller’s pricing information and the contents of Seller’s quotation or proposal and Buyer’s purchase order, exchanged between the parties is deemed confidential (“Confidential Information”). Each party agrees to maintain the other party’s Confidential Information in confidence, to not disclose the same to any third parties, and to use it only in connection with this sale. These restrictions shall expire two (2) years after the date of disclosure. This provision does not modify or supersede any separate confidentiality or nondisclosure contract signed by the parties. 10. FORCE MAJEURE: Seller shall not be liable for any delay in performance or nonperfor- mance which is due to war, fire, flood, pandemic, acts of God, acts of third parties, acts of governmental authority or any agency or commission thereof, accident, breakdown of prod- ucts, differences with employees or similar or dissimilar causes beyond Seller’s reasonable control, including but not limited to, those interfering with production, supply or transporta- tion of products, raw materials or components or Seller’s ability to obtain, on terms Seller deem reasonable, material, labor, products or transportation. 11. MERGER CLAUSE: This Contract entirely supersedes any prior oral or written representa- tions, correspondence, proposals, or contracts between the parties regarding the products. This writing constitutes the final and total expression of such contract between the parties, and it is a complete and exclusive statement of the terms of that contract. 12. ASSIGNMENT: Neither party may assign this Contract without the written consent of the other party, except that Seller may assign this Contract to a third party that acquires substantially all of Seller’s assets and Seller may assign the flow of funds arising out of this Contract. 13. COMPLIANCE WITH LAWS. Each party agrees to comply with all applicable laws in the performance of its obligations; Buyer shall not trans-ship, re-export, divert or redirect Products outside of the original country of delivery without Seller’s prior written consent. 14. GOVERNING LAW: This Contract shall be governed by and construed in accordance with the laws of the State of Michigan, without regard to the Convention for the International Sale of Goods (CISG), which shall not apply.

U.S. 800-626-6653 • Canada 800-387-6600 • dme.net • store.dme.net

6

6

Hot Runner Systems Sales and Ordering Information

U.S.A. TERMS AND CONDITIONS OF SALE: See previous page.

PHONE ORDERS – TOLL FREE: 800-626-6653. DME’s Customer Service Dept. operates Monday through Friday from 8 a.m. to 6 p.m. E.S.T. Calls can be made from anywhere in the continental U.S. and Puerto Rico (Puerto Rico: use “137” prefix instead of “1”). Our Customer Service Representatives will be happy to answer your questions on DME products or services, provide on-the-spot feedback on product availability and shipping details, or take any messages you wish relayed to your local DME sales, manufacturing or technical service representatives. MAIL ORDERS: If you prefer to order by mail, please address your order to: n DME Company, 29111 Stephenson Highway, Madison Heights, Michigan 48071-2330, FAX: 888-808-4363 ATTN: Customer Service Dept. FAX: You may fax your order to: • DME Customer Service • 248-544-5113 or 888-808-4363 CHECKS OR MONEY ORDERS: When paying invoices by check or money order, please make payable to DME Company. include remittance copy of invoice and mail to: DME Company, PO Box 854867 Minneapolis, MN 55485-4867 WALK-IN ORDERS, PICK-UPS AND RETURNS: If desired, ordered products in stock at your nearest DME Service Center can be picked up rather than shipped. Walk-in orders at Service Center locations can also be processed while you wait. Products being returned for repair or exchange should be processed through Customer Service prior to being returned. SPECIAL MACHINING SERVICES: Prints for quotation on special machining work can be sent by EDI to dme_cad@dme.net.

For delivery information on special mold base orders or to check status of special work in progress please contact Customer Service at 800-626-6653 or email dme@dme.net

CANADA

Terms and Conditions of Sale: See previous page. Orders, Quotes, Pickups, Returns: Please contact 800-387-6600 Check or Money Orders: Make payable to DME Company. Include remittance copy of invoice and mail to: 5345 Outerdrive - Unit 3, Oldcastle, ONT N9G 0C4.

U.S. 800-626-6653 • Canada 800-387-6600 • dme.net • store.dme.net

Hot Runner & Temperature Control Warranty Hot Runner Systems

7

7

DME Company 29111 Stephenson Highway, Madison Heights, MI 48071 Tel. 248/398-6000 n FAX 248/544-5113

DME Hot Runner Systems and Temperature Controllers are warranted pursuant to DME Company’s standard terms and conditions (see page 5) for the time periods set forth below. The warranty (i) covers items sold and shipped [supplied in accordance with orders placed by the customer with DME on or after JULY 1, 2003], (ii) applies only to the original DME customer and, (iii) is not transferable to subsequent owners of the product except as specifically set forth herein (see Transferability below for conditions). WARRANTY PERIODS APPLICABLETO SPECIFIED DME PRODUCTS; COVERAGE STARTS UPON DATE OF SHIPMENT: Item Coverage DME Stellar and Hot One Hot Halves (plates designed, machined & assembled by DME, excluding Electrical Parts) DME-Global Blue Warranty tag installed on Hot Half Plastic leakage, due to manufacturing defect, within hot runner plates covered for Two (2) years; excluding Gate Detail. DME StellarONE Fixed and Valve Gate Hot Halves (plates designed, machined & assembled by DME, excluding Electrical Parts) DME-Global Blue Warranty tag provided with components Plastic leakage, due to manufacturing defect, within hot runner plates covered for ONE (1) year; excluding Gate Detail.

DME Hot One, Stellar & StellarONE Fixed and Valve Gate Manifold and Components (neither plates nor assembly supplied by DME, excluding Electrical Parts) DME-Global Blue Warranty tag provided with components DME-CN Smart Fixed Gate and Valve Gate Hot Halves and Manifold & Components (excluding Electrical Parts) DME-Global Black Warranty tag provided with components

One (1) year on components only.

No warranty outside of Country of Manufacture. Contact Country of Manufacture for local warranty coverage. Warranty Coverage is not transferrable outside of country of origin.

DME Electrical Parts (all heaters and thermocouples)

One (1) year

DME Mold Controls and Valve Gate Controls ( excluding Fuses & Triacs, Power Packs & Trolley as appropriate )

One (1) year - Pumping systems, Valves & Solenoids Two (2) years - Smart Series Mainframes & Modules TSP, TSP Plus & SVG Electronic Controllers

Replacement or repair will be made at the election of DME; implemented at a DME facility and/or by shipment of replacement parts to the customer for installation and/or return of defective parts to DME for repair. Transferability: This warranty may be transferred by the original DME Customer to a subsequent owner of the product if all of the following conditions exist: (i) the original DME Customer purchased the product for purposes of re-sale or other immediate transfer and DME was made aware of these purposes at the time of purchase in writing, (ii) within thirty (30) days from the date of invoice, DME is notified in writing of the transfer and provided with the name of the new owner (hereafter “Transferee”), the contact person of the Transferee and the Transferee’s address. Exclusions: • Normal wear of the system and components including, but not limited to: Nozzle Tips, Nozzle Seal Rings, and Electrical connectors • Damage to the critical seal-off areas on the manifold, nozzle bodies, or in the mating cavities or cavity inserts caused by improper assembly, operation, disassembly and maintenance • Wear or damage resulting from corrosion or processing of abrasive/aggressive resins • Damage due to failure to follow recommended operation and maintenance procedures specified in the DME Hot Runner Manual, Hot Runner Nameplate, Service Bulletins, User Manuals or failure to follow standard industry operation and maintenance procedure • Damage caused by abuse, neglect, and failure to adhere to DME instructions and operational recommendations • Damage caused by improper installation, operation and maintenance • Damage resulting from modifications to the product or component parts, abuse or neglect • Failure caused by modifications made to the product without the prior written approval of DME • Damage resulting from operation of products at injection pressures greater than 20,000 psi (1360 bar) on Hot One, Stellar & Smart One VG Systems;

unless specifically designed and manufactured for higher pressure applications in agreement with manufacturer • Damage or failure caused by the product’s inability to perform as a component of a system design not supplied by DME • Operator absence or operator error • Operator maintenance and training capability • Electrical interruptions

• Events beyond the control of DME • Errors or actions by a third party • Non-compliance with local laws, codes, ordinances or regulations codes or bylaws unless DME is informed of them by our customer at the time of order placement

U.S. 800-626-6653 • Canada 800-387-6600 • dme.net • store.dme.net

8

8

DME Hot Runner Overview Hot Runner Systems

DME: Your essential resource for hot runner solutions

Whether your application requires best-in-class components or a turnkey hot-half system, DME has a hot runner solution that meets your needs.

®

DME: An Essential Resource for Hot Runner Productivity Moldmakers, molders and mold designers worldwide look to DME for essential hot runner solutions — whether that is a single, best-in-class component or a complete, fully functioning hot half system. Offering the industry’s broadest range of hot runner products and services as well as an unsurpassed knowledge and expertise, DME is committed to helping customers achieve maximum productivity, reliable operation, and better performance.

System Solutions DME offers a comprehensive family of hot runner systems built on our modular architecture making custom configuration easy and quick. Systems include: • Stellar ® Micromolding Systems engineered for tight pitch molding • The Hot One 250, 375 and 625 series

A wide range of DME nozzles allows versatility in system selection

Stellar Micromolding Nozzles provide application flexibility

U.S. 800-626-6653 • Canada 800-387-6600 • dme.net • store.dme.net

9

9 …from components and manifolds to turnkey hot halves Hot Runner Systems

Our goal is simple: to be an essential resource for your molding challenges. Every step of the way.

®

Specialized Systems As one of the world’s leading hot runner manufacturers, we recognize that some application challenges demand specialized solutions. Offerings include: • Stellar Manifold and Components • Stellar Hot Halves • Hot One Manifold and Components • Hot One Hot Halves

Knowledge That Gives You an Advantage

Service and Support to Keep You Productive DME provides essential support to keep your hot runner systems in-service. Our dedicated hot runner service center is staffed by trained, experienced technicians who support DME systems, as well as other brands, to provide help when and where you need it, every step of the way.

Our team of trained, experienced experts can help you with needs analysis, design, configuration, operation, and all the other services that enable you to focus on your core business. • Applications engineering • Moldflow analysis

Stellar & Hot One Systems are custom configured for your application

Moldflow predictive analysis optimizes part design and lowers costs

DME Hot Runner Service Center provides total support for your hot runner system

U.S. 800-626-6653 • Canada 800-387-6600 • dme.net • store.dme.net

DECEMBER 2024

www.DME.net

DME Hot Runner Technology Selection Guide

GENERIC POLYMER NAME (TRADE NAME) [A=AMORPHOUS or C=CRYSTALLINE] NOTE:THE CHART BELOW SHOWS COMMODITY RESINS IN ORANGETYPE; ALL OTHERS ARE ENGINEERING RESINS.

The values expressed in grams are for reference only and are determined by using a nominal wall thickness of 1.8mm (.070") and unfilled poly- propylene Part dimension, wall thickness, length of fill within part, mold conditions and molding parameters must also be considered. NOTE: If flame retardant is present in the desired resin grade, please contact DME for product suitability or application guidance.

Resin Application Key Good Contact DME

Flow Capacity

Not recommended

(Grams)

Polymer Viscosity Key L=Low M=Medium H=High

Recommended Gate Diameter Range

Viscosity

Min (mm)

Max (mm)

Min (inch)

Max (inch)

Low MFI.16

Medium MFI 7-16

High MFI .02-7 LLHMHMLMHMMMHHMLHHHHHHHLHHMHHLLHHHM

NOZZLES

TIP

Sprue Tip

1.5

2.0

0.061

0.079

20

15

10

StellarONE-04 Thermal Gate

Point Gate Bodiless

0.8

1.5

0.033

0.059

10

10

7

Point Gate Full Body

1.0

1.5

0.041

0.059

10

10

7

Sprue Tip

1.5

3.0

0.061

0.118

500

400

225

StellarONE-06 Thermal Gate

Point Gate Bodiless

0.8

2.0

0.033

0.079

175

125

80

Point Gate Full Body

1.0

2.0

0.041

0.079

175

125

80

Sprue Tip

2.5

3.0

0.102

0.118

625

575

325

StellarONE-08 Thermal Gate

Point Gate Bodiless

0.8

2.5

0.033

0.098

250

175

125

Point Gate Full Body

1.5

2.5

0.061

0.098

250

175

125

Sprue Tip

2.5

3.5

0.102

0.138

850

700

425

StellarONE-10 Thermal Gate

Point Gate Bodiless

1.0

3.0

0.041

0.118

310

200

150

Point Gate Full Body

1.5

3.0

0.061

0.118

310

200

150

Sprue Tip

3.0

4.0

0.122

0.157

1000

775

475

StellarONE-12 Thermal Gate

Point Gate Bodiless

1.0

3.2

0.041

0.126

500

375

275

Point Gate Full Body

2.0

3.2

0.082

0.126

500

375

275

Sprue Tip

3.0

4.5

0.122

0.177

1500

1100

750

StellarONE-16 Thermal Gate

Point Gate Bodiless

1.5

3.5

0.061

0.138

800

550

400

Point Gate Full Body

2.5

3.5

0.102

0.138

800

550

400

Sprue Tip

1.5

2.0

0.061

0.079

400

300

150

StellarONE-06 Valve Gate

Point Gate Bodiless Direct Valve Gate

1.0

2.0

0.041

0.079

225

150

90

Point Gate Full Body Direct Valve Gate

1.5

2.0

0.061

0.079

225

150

90

Sprue Tip

2.5

2.5

0.102

0.098

500

450

250

StellarONE-08 Valve Gate

Point Gate Bodiless Direct Valve Gate

1.0

2.5

0.041

0.098

450

300

220

Point Gate Full Body Direct Valve Gate

2.5

2.5

0.102

0.098

450

300

220

Sprue Tip

2.5

2.5

0.102

0.098

775

625

375

StellarONE-10 Valve Gate

Point Gate Bodiless Direct Valve Gate

1.0

2.5

0.041

0.098

610

460

280

Point Gate Full Body Direct Valve Gate

2.5

2.5

0.102

0.098

610

460

280

Sprue Tip

4.0

4.5

0.163

0.177

900

725

425

StellarONE-12 Valve Gate

Point Gate Bodiless Direct Valve Gate

1.5

4.5

0.061

0.177

725

525

315

Point Gate Full Body Direct Valve Gate

4.0

4.5

0.163

0.177

725

525

315

Sprue Tip

5.0

6.0

0.204

0.236

1200

950

600

StellarONE-16 Valve Gate

Point Gate Bodiless Direct Valve Gate

2.0

6.0

0.082

0.236

940

640

475

Point Gate Full Body Direct Valve Gate

5.0

6.0

0.204

0.236

940

640

475

Available only as a DME Designed and Manufactured Manifold & Components or Fully Assembled and Wired Hot Half

APRIL 2024

www.DME.net

DME Hot Runner Technology Selection Guide

GENERIC POLYMER NAME (TRADE NAME) [A=AMORPHOUS or C=CRYSTALLINE] NOTE:THE CHART BELOW SHOWS COMMODITY RESINS IN ORANGETYPE; ALL OTHERS ARE ENGINEERING RESINS.

The values expressed in grams are for reference only and are determined by using a nominal wall thickness of 1.8mm (.070") and unfilled poly- propylene Part dimension, wall thickness, length of fill within part, mold conditions and molding param- eters must also be considered. NOTE: If flame retardant is present in the desired resin grade, please contact DME for product suitability or application guid- ance.

Resin Application Key Good Contact DME

Not recommended

Flow Capacity

(Grams)

Polymer Viscosity Key L=Low M=Medium H=High

Recommended Gate Diameter Range

Viscosity

Max (inch) 0.125 0.100 0.125 0.100 0.187 0.125 0.187 0.125 0.312 0.175 0.187 0.175 0.160 0.060 0.125 0.062 0.125 0.125 0.100 0.100 0.187 0.125 0. 312 0. 175 0.175

Low MFI-16

Medium MFI 7-16

High MFI .02-7 LLHMHMLMHMMMHHMLHHHHHHHLHHMHHLLHHHM

NOZZLES

Min (mm) Max (mm) Min (inch)

TIP

Sprue Tip

2.0 0.7 2.0 0.7 3.2 0.7 3.2 0.7 4.7 3.2 4.7 3.2 4.1 1.5 3.2 1.6 3.2 2.0

3.1 2.5 3.1 2.5 4.7 3.1 4.7 3.1 7.9 4.4 7.9 4.4 4.1 1.5 3.2 1.6 3.2 3.1 2.5 2.5 4.7 3.1 7.9 4.4 4.4

0.080 0.028 0.080 0.060 0.125 0.028 0.125 0.060 0.187 0.125 0.187 0.125 0.160 0.060 0.125 0.062 0.125 0.080 0.050 0.060 0.125 0.050 0. 187 0.1 25 0.125

625 200 625 200

475 150 475 150 750 200 750 200

315 100 315 100 450 150 450 150 750 400 750 400 300

Hot One 250 Series (Coil Heater) Hot One 250 Series (Cast-in Heater) Hot One 375 Series (Coil Heater) Hot One 375 Series (Cast-in Heater) Hot One 625 Series (Coil Heater) Hot One 625 Series (Cast-in Heater)

Standard Point Gate Tip

Sprue Tip

Standard Point Gate Tip

Sprue Tip

1000

Standard Point Gate Tip

310

Sprue Tip

1000

Standard Point Gate Tip

310

Sprue Tip

1500

1100

Standard Point Gate Tip

800

550

Sprue Tip

1500

1100

Standard Point Gate Tip S-Series & T-Series

800 700 300 500 300 500 700 250 250

550 500 150 300 150 300 500 175 175 800 250

E-Series

50

Radius Hot Sprue Bushing

ER-Series & TR-Series High Performance Series

200

50

Sprue Tip

200 350 125 125 500 200 850 500 500

D-MAX 250 Series High Performance D-MAX 375 Series High Performance D-MAX 625 Series High Performance

Standard Point Gate Tip

Wear Resistant Point Gate Tip 1.3

Sprue Tip

1.5 3.2

Standard Point Gate Tip

1100

Wear Resistant Point Gate Tip 1.3

350

Sprue Tip 250 Series

1. 7 3.0 3.0

1600

1200

650

90 0

High Performance

900

650

Available only as a DME Designed and Manufactured Manifold & Components or Fully Assembled and Wired Hot Half

12

Hot Runner Selection Guide Hot Runner Systems

DME Hot Runner Technology Selection Guide - APRIL 2024 - www.dme.net

GENERIC POLYMER NAME (TRADE NAME) [A=AMORPHOUS or C=CRYSTALLINE]

COMMODITY RESINS

The values expressed in grams are for reference only and are determined by using a nominal wall thickness of 1.8mm (.070") and unfilled poly- propylene Part dimension, wall thickness, length of fill within part, mold conditions and molding parameters must also be considered. NOTE: If flame retardant is present in the desired resin grade, please contact DME for product suitability or ap- plication guidance.

Resin Application Key Good

Contact DME Not recom- mended

Flow Capacity

(Grams)

Polymer Viscosity Key

Recommended Gate Diameter Range

L=Low M=Medium H=High

Viscosity

Low MFI- 16

Medium MFI 7-16

High MFI .02-7

Min (mm)

Max (mm)

Min inch)

Max (inch)

LLHMHMLMHMM

NOZZLES

TIP

Equatemp 3/4” Dia Single-Zone HSB Equatemp 1” Dia Single-Zone HSB

Sprue Tip

1.2 2.4 0.047 0.094 300 150

75

Sprue Tip

1.5 3.5 0.062 0.140 550 400

250

Std Point Gate Tip Wear Resisstant Point Gate Tip

0.8 1.5 0.030 0.060 250 175

125

1.5 2.5 0.060 0.100 250 175

125

Sprue Tip

3.1 5.5 0.125 0.218 1000 775

475

Equatemp 1.5” Dia Single-Zone HSB

Std Point Gate Tip Wear Resisstant Point Gate Tip

0.8 2.0 0.060 0.200 500 375

275

1.5 2.5 0.080 0.200 500 375

275

Sprue Tip

1.5 2.4 0.062 0.094 300 150

75

Equatemp 3/4” Dia Dual-Zone HSB

Std Point Gate Tip Wear Resisstant Point Gate Tip

0.8 1.5 0.030 0.060 100

75

50

1.5 2.0 0.060 0.080 100

75

50

Sprue Tip

2.4 3.5 0.094 0.140 550 400

250

Equatemp 1” Dia Dual-Zone HSB

Std Point Gate Tip Wear Resisstant Point Gate Tip

0.8 2.0 0.030 0.080 250 175

125

1.5 2.5 0.060 0.100 250 175

125

If you are not finding all the information you require to select a Hot Runner System please contact: Technial Service Department - DME_Tech_Service@DME.net

U.S. 800-626-6653 • Canada 800-387-6600 • dme.net • store.dme.net

13

13

Standard Global Manifold & Plastic Materials and Specifications

DME Global Manifolds and Components are standardized worldwide to ensure that even the smallest detail provides operational excellence regardless of where DME hot runner products are used. Whether you’re relying on a quick-delivery manifold or an applications-engineered, custom manifold, the DME Global Manifold Standard ensures optimal hot runner performance no matter where in the world it was built. Key Features of the DME Global Manifold Include: • Flexible tubular heaters • Locating rings that fit virtually any injection press platen hole diameters • Heated Manifold Extension Nozzles available • High-tolerance, press-fit heaters

• Upper and center Manifold supports constructed of high-strength, low- heat conductive titanium that minimizes heat loss and maintains an even heat profile • J-type thermocouples are black-and-white, coinciding with the IEC 584-3 International Standard • Flow channel sizes range from 6mm to 16mm

DME customers are assured that DME Manifold Systems are designed and built with a global standard that ensures efficient molding anywhere in the world. And, since replacement parts are identical worldwide, they are readily available wherever your mold is operating, not just where it was built. All DME nozzles, including, Stellar and the Hot One, perform flawlessly with the DME Global Manifold Standard.

PLASTIC MATERIAL PROCESS CONDITIONS

PROCESS TEMPERATURE

MOLD TEMPERATURE

HOT RUNNER TEMPERATURE

DENSITY MELTING

SOLID DENSITY

STANDARD RESIN SYMBOL

MATERIAL

[g/cm 3 ] [Ibs/inch 3 ] [g/cm 3 ] [Ibs/inch 3 ]

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

Styrene Butadiene

SB

210 220 230 210 300 260 200 225 330 300 265 220 255 240 180 235

410 428 446 410 572 500 392 437

70 45 80 45 80 80 25 40

158 113 176 113 176 176

230 240 255 230 330 300 225 245 370 330 290 250 280 265 200 250

446 464 491 446 626 572 437 473 698 626 554 482 536 509 392 482

0.93 0.93 0.99 0.95 1.08 0.99 0.74 0.73 1.13 1.53 1.44 0.98 1.09 0.78 1.16 1.09

0.0366 0.0366 0.0358 0.0343 0.0390 0.0358 0.0267 0.0264 0.0408 0.0553 0.0520 0.0354 0.0394 0.0282 0.0419 0.0394

1.02 1.11 1.08 1.05 1.20 1.13 0.96 0.91 1.37 1.70 1.57 1.14 1.26 0.90 1.42 1.18

0.0369 0.0401 0.0390 0.0379 0.0434 0.0408 0.0347 0.0329 0.0495 0.0614 0.0567 0.0412 0.0455 0.0325 0.0513 0.0426

Polyurethane

PUR SAN

Styrene-acrylonitrile

Polystyrene

PS PC

Polycarbonate

Polyphenylene Oxide-Styrene

PPO

Polyethylene Polypropylene

PE PP

77

104 329 230 140 194 194

Polyether-etherketone Polyphenylene Sulfide

PEEK PPS PBT PA 6 PA 66

626 165 572 110

Polyebutylene Terephthalate

509 428 491 464

60 90 90 35

Polyamide 6 Polyamide 66

Thermal Plastic Elastomers

TPE

95

Polyoxymethylene (Polyacetal)

POM

356 100

212 158 158

Polymethyl Methacrylate

PMMA

455 437

70 70

Acrylonitrile Butadiene Styrene 0.0390 NOTE: Temperature and density values shown above are general, and may not apply to your application. Please refer to proper processing data for the resin grade intended for your specific application. Failure to use temperature settings appropriate to the specific resin and resin grade intended for your application may result in poor part quality, or inability to produce acceptable molded parts. ABS 225 250 482 0.95 0.0343 1.08

U.S. 800-626-6653 • Canada 800-387-6600 • dme.net • store.dme.net

14

14

Bushing Selection

HOT SPRUE BUSHING TIP STYLE

For use where gate vestige is allowed. Provides low resistance to flow with excellent flow rates. Extended style provides additional stock for machining profiles or part contours.

SPRUE GATE TIP STANDARD / EXTENDED

Ideal for low vestige commodity and engineering grade resin applications. The Ring Gate features a sealed tip for efficient shut-off at the part surface. Available with standard or wear resistant needles. Extended style provides additional stock for machining profiles or part contours.

RING GATE TIP STANDARD / EXTENDED

Suitable for high viscosity resins, engineering plastics and applications requiring optimum gate cosmetics with minimal gate vestige. Available with standard or wear resistant needles.

POINT GATE TIP

BUSHING TIP AND PLASTIC MATERIAL COMPATIBILITY

THERMOPLASTIC RESIN TYPE

AMORPHOUS

SEMI-CRYSTALINE

NOZZLE

SPRUE GATE TIP STANDARD / EXTENDED

RING GATE TIP STANDARD / EXTENDED

POINT GATE TIP

Green Yellow Red

– Works well with this resin – Contact DME Engineering for guidance – Not recommended

U.S. 800-626-6653 • Canada 800-387-6600 • dme.net • store.dme.net

15

13

Hot Runner Quote Request Form Hot One Hot Runner Technology

EMAIL TO DME_TECH_SERVICE@DME.NET OR FAX United States: 888-808-4363 • Canada: 800-461-9965 • International: 248-398-7394

DME 29111 Stephenson Highway Madison Heights, MI. 48071-2383

Applications Engineering QUOTE REQUEST FORM Email to: mailto: DME_Tech_Service@dme.net

Tech Service Approval, Final Drawings and In-House Due Date Required for Firm Quote - QUOTE TYPE

Preliminary

Firm

Customer’s In-House Date Requirement

Date

Sales Rep Contact

Company Address Address

Phone

Fax

City

E-Mail

State

Zip

Acct#

End User Melt Temp

Molding Material Manufacturer Flame Retardant Color Changes Filler

deg. (min)

Range

(max)

None

Glass

Other Percent

%

Yes Yes

No Melt Flow Index

No

Mold Temp

deg.

New Mold

Retrofit

DME Mold Base to be Quoted Mold Base Drawings Supplied

Mold Base Size

Gating Into

Part

Dimple

Runner

StellarONE (Fixed Point/Sprue Tip only) / Hot One

StellarONE (Valve Gate)

Gate Style

Sprue Other

Ext Sprue

Tip/Point

WR

VG–Bodiless VG-Sprue

VG–Full Body

VG–Full Body Ext’d

Number of Drops

Number of Cavities

Control:

Pneumatic

Hydraulic *** 700 PSI MAX***

Part Name

Part Number

Job #

Part Drawing Supplied Wall Thickness of Part

Yes

No

Sample Supplied CAD Data Supplied Total Shot Weight

Yes Yes

No No

Part Weight Runner Weight

Grams Grams

Ounces Ounces

Grams

Ounces

Type of Quote Requested

M&C (system)

Hot Half – Plate Steel

#2 (standard)

420SS

iControl

Drop Spacing

A= A1= B= B1=

Drop Spacing

Plate Width Plate Length

X= Y= L=

Molding Elevation

# of Columns # of Rows

NOTES:

AE001 Rev3.15.24

Page 1 of 2

U.S. 800-626-6653 • Canada 800-387-6600 • dme.net • store.dme.net

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10-11 Page 12-13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42 Page 43 Page 44 Page 45 Page 46 Page 47 Page 48 Page 49 Page 50 Page 51 Page 52 Page 53 Page 54 Page 55 Page 56 Page 57 Page 58 Page 59 Page 60 Page 61 Page 62 Page 63 Page 64 Page 65 Page 66 Page 67 Page 68 Page 69 Page 70 Page 71 Page 72 Page 73 Page 74 Page 75 Page 76 Page 77 Page 78 Page 79 Page 80 Page 81 Page 82 Page 83 Page 84 Page 85 Page 86 Page 87 Page 88 Page 89 Page 90 Page 91 Page 92 Page 93 Page 94 Page 95 Page 96 Page 97 Page 98 Page 99 Page 100 Page 101 Page 102 Page 103 Page 104 Page 105 Page 106 Page 107 Page 108 Page 109 Page 110 Page 111 Page 112 Page 113 Page 114 Page 115 Page 116 Page 117 Page 118 Page 119 Page 120 Page 121 Page 122 Page 123 Page 124 Page 125 Page 126 Page 127 Page 128 Page 129 Page 130 Page 131 Page 132 Page 133 Page 134 Page 135 Page 136 Page 137 Page 138 Page 139 Page 140 Page 141 Page 142 Page 143 Page 144 Page 145 Page 146 Page 147 Page 148 Page 149 Page 150 Page 151 Page 152 Page 153 Page 154 Page 155 Page 156 Page 157 Page 158 Page 159 Page 160 Page 161 Page 162 Page 163 Page 164 Page 165 Page 166 Page 167 Page 168 Page 169 Page 170 Page 171 Page 172 Page 173 Page 174 Page 175 Page 176 Page 177 Page 178 Page 179 Page 180 Page 181 Page 182 Page 183 Page 184 Page 185 Page 186 Page 187 Page 188 Page 189 Page 190 Page 191 Page 192 Page 193 Page 194 Page 195

Made with FlippingBook - professional solution for displaying marketing and sales documents online