Trex® Lighting Installation Overview

Trex® Lighting Installation Overview for use when installing the Trex® Lighting collection.

TREX® LIGHTING WIRING OVERVIEW, POST PREPARATION, RISER LIGHT INSTALLATION » Y OU MUST USE A TREX 24V TRANSFORMER ON ALL TREX 24V LIGHTING INSTALLATIONS. » YOU MUST INSTALL A GFCI CIRCUIT AS THIS IS REQUIRED TO PREVENT DAMAGE TO LIGHTING FROM ELECTRICAL SURGES. » THIS SYSTEM IS NOT BACKWARDS COMPATIBLE WITH PREVIOUS TREX LIGHTING SYSTEMS, THIS SYSTEM IS 24V AND CANNOT BE USED WITH 12V COMPONENTS. » TREX LIGHTING OPERATES ON DC POWER. NEVER MIX AC AND DC FIXTURES ON THE SAME CIRCUIT. DOING SO WILL RESULT IN EXTREMELY PREMATURE FIXTURE FAILURE AND IS NOT COVERED BY THE TREX LIMITED WARRANTY. » INSTALL WIRING AND SPLITTERS BEFORE DECKING AND RAILING HAVE BEEN INSTALLED. » DO NOT RUN WIRES BETWEEN JOISTS AND DECK BOARDS. » AVOID RAILING BRACKETS WHEN RUNNING WIRES UP POSTS. » CAP ALL UNUSED CONNECTIONS WITH CAPS PROVIDED OR WEATHER-RESISTANT SILICONE TO PREVENT WATER DAMAGE OR CORROSION. » IF INSTALLING UNDER RAIL LIGHTING, PREP POSTS, BLOCKING, AND JOISTS ACCORDINGLY PER INSTRUCTIONS BELOW. REVIEW DETAILED RAILING INSTRUCTIONS FOR THE INSTALLATION OF THE UNDER-RAIL LIGHTING. » TREX LIGHTING IS NOT RECOMMENDED FOR POSTS INSTALLED IN CONCRETE. POWER SUPPLY AND SYSTEM WARNINGS: »  DO NOT INSTALL TREX LIGHTING IN CLOSE PROXIMITY TO POOLS OR HOT TUBS AS CHEMICALS FROM THE WATER CAN DAMAGE LIGHTING FIXTURES. » DO NOT INSTALL WIRING UNDER HEAVY WEIGHT OR LOAD AS THIS CAN DAMAGE WIRING. » IF USING STAPLES TO SECURE WIRING, NEVER FULL DRIVE STAPLES IN AS THIS CAN PINCH WIRING; WIRING SHOULD MOVE UNDER STAPLES. » IT’S BEST PRACTICE TO PROTECT WIRE THAT IS CLOSE TO THE GROUND WITH CONDUIT OR WIRE LOOM TO PREVENT RODENT DAMAGE. » A VOID EXTREME ANGLES, PRESSURE, OR TENSION ON WIRING, AS THIS CAN CAUSE PINCHING OF THE WIRING AND LEAD TO LIGHTING FAILURE. » F IRE HAZARD WARNING: RISK OF FIRE. DO NOT PLACE INSULATION UNDER THE TERMINAL PLATE. CHECK CONNECTION AFTER INSULATION. » S HOCK HAZARD WARNING: WARNING – RISK OF ELECTRIC SHOCK. INSTALL THE POWER UNIT 5 FEET OR MORE FROM A POOL, SPA, OR FOUNTAIN. WHERE THE POWER UNIT IS INSTALLED (A) INDOORS WITHIN 10 FEET OF A POOL, SPA, OR FOUNTAIN, OR (B) OUTDOORS, CONNECT THE POWER UNIT TO A RECEPTACLE PROTECTED BY A GFCI. » DIMMER COMPATIBILITY: NOT FOR USE WITH AC DIMMERS SUCH AS ELV, TRIAC, AND 0-10V. » PARALLEL CONNECTION: DO NOT CONNECT TWO OR MORE POWER SUPPLIES IN PARALLEL. » FOR USE ONLY WITH TREX LOW VOLTAGE 24VDC LANDSCAPE LIGHTING SYSTEMS ONLY. » NOT FOR USE IN DWELLING UNITS. » FOR OUTDOOR USE ONLY.

1

LIGHT-OVERVIEW-1026

TABLE OF CONTENTS:

General Notes ............................................................................................................................ Page 1 Table Of Contents...................................................................................................................... Page 2 Parts List ....................................................................................................................................... Page 3 Number Of Lights Per Transformer .................................................................................. Page 3 Wiring Overview Examples .................................................................................................. Page 4 Framing And Blocking Preparation .................................................................................. Page 5 Splitter Installation ................................................................................................................... Page 6 Wiring Installation .................................................................................................................... Page 6 Making Connections ................................................................................................................ Page 7 Riser Light Installation ............................................................................................................ Page 7 Linear Light Installation........................................................................................................... Page 8 Compatible Post/Railing With Lighting Chart ............................................................. Page 9 Preparing Pressure-Treated Posts/Post Sleeves For Lighted Caps And Under-Rail Lighting ........................................................................................ Page 10 Preparing Post Sleeve With Transcend Composite Railing .................................... Page 11 Preparing Post Sleeve With Select & Enhance Composite Railing ..................... Page 12 Preparing Post Sleeve With Signature Railing ............................................................. Page 12 Preparing Post Sleeve With Select Aluminum Railing .............................................. Page 13 Preparing Post Sleeve With Enhance Steel Railing .................................................... Page 14 Post Sleeve And Under-Rail Lighting Installation ....................................................... Page 15 Transcend Composite Railing Bracket Installation To Post Sleeve ...................... Page 15 Signature Railing Bracket Installation To Post Sleeve ............................................... Page 16 Select Aluminum Railing Bracket Installation To Post Sleeve ............................... Page 17 Enhance Steel Railing Bracket Installation To Post Sleeve ..................................... Page 18 Metal (Aluminum And Steel) Post Preparation ......................................................... Page 19 Signature Railing Bracket Installation To Aluminum Post ...................................... Page 20 Select Aluminum Railing Bracket Installation To Aluminum Post ....................... Page 21 Enhance Steel Railing Bracket Installation To Steel Post ....................................... Page 22 Under-Rail Light To Metal Post Installation ................................................................... Page 23 Preparing Signature X-Series Anchor Posts ................................................................ Page 24

2

LIGHT-OVERVIEW-1026

TREX® LIGHTING–PARTS

A Dimmer

B Linear Riser Light

L Dimmer Remote

D Under Rail Light

C Oval Riser Light

F Y Splitter Note: Y-Splitter is included with Linear Riser Light (NOT sold separately).

H2 Wiring 5' H4 Wiring 20'

H1

E Timer

Wiring 2 1/2'

H3 Wiring 10'

G2

G1

60W Transformer

96W Transformer

I Stair Rail Clip

K1 Signature/Select Aluminum Post Cap Light

K2 X-Series Post Cap Light

K3 4 x 4 Post Sleeve Cap Light

J Splitter

Number of Lights Per Transformer 1 Branch 2 Branches

Transformer Splitter One Branch

3 Branches

60W 90W

16

32 48

48 72

24

Two Branch

Transformer Splitter

*3 Oval Risers = 1 Light

WARNING • INGESTION HAZARD: This product contains a button cell or coin battery. • DEATH or serious Injury can occur if ingested. • A swallowed button cell or coin battery can cause Internal Chemical Burns in as little as 2 hours. • KEEP new and used batteries OUT OF REACH of CHILDREN. • Seek Immediate medical attention if a battery is suspected to be swallowed or inserted inside any part of the body.

Three Branch

Transformer Splitter

3

LIGHT-OVERVIEW-1026

TREX® LIGHTING–WIRING OVERVIEW

Example 1 Under Rail Lights and Linear Riser Lights

= 8 Lights = 3 Lights = 2 Lights

E

G

1

2

3

2

4

1

5

6

1

7

D

8

1 2

J

B

3

F

Example 2 Lighted Post Caps and Oval Riser Lights

1

= 5 Lights = 2 Lights

2

(6 Oval Risers) = 4 Lights

4

K

E

3

3

G

4

5

2

1

21

J

1

C

Note: Pictures above are examples of how wiring could be installed based on customer preference of lighting components being used, as well as general representation of placement of wiring components. All wiring and splitters should be mounted to the inside of the framing.

4

LIGHT-OVERVIEW-1026

TREX® LIGHTING–WIRING OVERVIEW/ CONTINUED

Tools Needed

Adjacent to Rim Joist

1" (25 mm)

1/2" (13 mm)

7/16" (11 mm)

Planning » When designing deck, plan locations of lights, power supply, and timer. These should be accessible for service when required. » Times must be installed vertically with receptacle To Splitter

4 x 4 Pressure Treated Post Location

GFCI Outlet

facing downward. Timer must be at least 1” from ground level when installed as per federal safety code regulations. Timer must be in view of the sun to use dusk/dawn feature. » First splitter must be installed within 20’ of transformer.

Dimmer (Optional)

Notched Blocking

Timer

Parallel to Joist

Transformer

Blocking Preparation » Refer to following images and cut out locations where required to allow for wiring placement. » Install pressure-treated posts per local code requirements, images below are general representations of blocking requirements.

Corner Post

Notched Blocking

4 x 4 Pressure Treated Post Location

Notched Blocking

4 x 4 Pressure Treated Post Location

5

LIGHT-OVERVIEW-1026

TREX® LIGHTING–SPLITTERS AND WIRING INSTALLATION

» ALWAYS INSTALL WIRING AND SPLITTERS BEFORE DECKING AND RAILING HAVE BEEN INSTALLED. » USE A SINGLE MALE CONNECTION ON SPLITTER TO CONNECT TO TRANSFORMER.

Post Caps

Decking Structure

6" (152 mm)

Attach wire to post with female connection at top of post and male connection at bottom to connect to splitter. Avoid running wire on side of posts where railing brackets or under-rail lights are to be installed. Leave approximately 6" of lead at top of wire to make connections with post cap.

Install splitters to inside of framing using hardware provided. Install at every post base where lighting is present and depending on spacing in between each type of light being used.

Oval Riser

Decking Structure

Oval Riser lights should be spaced 20” or less apart. If wider, an extension cable will be required. Ensure that splitters are installed within reach of first oval light or use wiring extensions when necessary.

Linear Riser Lights

Wiring must be run under decking structure, behind stringers and/or risers. Example shown here. Mount splitter high enough to ensure some slack in under-rail light wire.

Make sure splitter is within 6” of first linear riser light. Ensure stair riser has overhang of 3/4” to allow for proper installation of linear riser light.

6

LIGHT-OVERVIEW-1026

TREX® LIGHTING–MAKING CONNECTIONS

First Splitter From Power Source

Oval Riser Lights Installation » Install riser lights after stairs and risers have been installed. » Avoid locations over stringers as holes are difficult to create.

1

Power in

Light connection

1

4" (102 mm)

Power out to next splitter

1. Attach male lead from lights to female (out) connections on splitter. Also attach connection wiring in between each splitter. Continue until all wiring from lighting and connector wires are attached between splitters.

1. Mark locations for each light, generally 4" above tread. Consult local codes for lighting requirements.

2

2

2. Drill a 1" diameter hole using Forstner bit, at least 1” deep into riser (if riser is thicker than 1", use a 1/2" drill bit to create a passage for wires).

2. Cap off all unused connections on splitters with caps provided.

3

3. Thread wires through hole. Press light into hole, ensuring lens in fully seated and oval light is in correct orientation. Make connections behind stairs from lead wire on oval light to female connection on splitter. Cap off any connections not being used. When daisy chaining oval riser lights, plug long female lead into short male lead.

7

LIGHT-OVERVIEW-1026

TREX® LIGHTING–MAKING CONNECTIONS

3

Linear Lights Installation » .Install riser lights after stairs and risers have been installed. » Ensure stair riser has overhang of 3/4" to allow for proper installation of linear riser light.

1

3. Install riser light clips to riser at evenly spaced locations where light is being placed. Use 3 clips for a 32" riser light and 4 clips for a 42" riser light. Install clips with “tabs side up” pressing against the underside of the stair tread. Install with screws provided.

1. D etermine location for linear riser light directly under the stair tread, mark location where hole needs to be drilled for wire.

4

2

2. U sing a 1/2" drill bit, drill through riser (and if required any framing).

4. T hread wire from stair riser light into drilled out hole. Push and snap stair riser light into clips. Connect wiring accordingly,

8

LIGHT-OVERVIEW-1026

TREX® LIGHTING–POST PREPARATION

Compatible Post with Lighting

Pressure- Treated post with 4 x 4 composite post sleeve

Pressure- Treated post with 6 x 6 composite post sleeve

Pressure- Treated post with All-in-One Post Sleeve

Treated post with Select Aluminum Post Sleeve

Signature & Select Aluminum Post

Enhance Steel Post (2” or 3”)

Signature X-Series Post

Railing System

Transcend Composite Railing systems Classic, T-Rail and Mesh Railing systems** Enhance Composite Railing systems** Signature Standard Railing

UR PC UR

UR PC UR

UR

UR PC UR

UR

UR PC

UR

UR PC

Signature Rod Rail

UR PC UR PC UR PC

UR UR UR

UR PC UR PC

Signature Mesh Rail Signature Glass Rail Signature X-Series Railing Select Aluminum Railing

PC

PC

UR PC UR

UR

UR PC

Enhance Steel Railing UR PC UR

UR

UR = Under Rail Light /PC = Post Cap

NOTES: » A LL TREX RAILING PRODUCTS ARE DESIGNED FOR POSTS TO BE INSTALLED AT CLEAR SPANS OF 6’ OR 8’. TREX SELECT T-RAIL IS ALSO AVAILABLE AT 10’ CLEAR SPAN. » IN MOST CASES COMPOSITE RAILING WILL BE SLIGHTLY LONGER TO ALLOW FOR POST PLACEMENT ISSUES, THUS TRIMMING RAILS MAY BE REQUIRED. » IF NOT INSTALLING CLEAR SPANS, PLAN AHEAD FOR POST AND RAILING PLACEMENT TO ENSURE THAT PANELS/BALUSTERS ARE CENTERED BE-TWEEN POSTS AND THERE IS ENOUGH RAIL CLEARANCE FOR ATTACHMENT TO BRACKETS. » IF USING THE SELECT™ ALUMINUM POST SLEEVE, COVER 4X4 PRESSURE-TREATED POST WITH PLASTIC, HOUSEWRAP, OR SIMILAR PRODUCT BEFORE INSTALLING ALUMINUM POST SLEEVE. » W HEN INSTALLING COCKTAIL POST-TO-POST RAILING CONFIGURATIONS WITH ALUMINUM POSTS, YOU MUST USE TALLER POSTS. FOR 36” RAILING HEIGHTS USE 42” POST, FOR 42” RAILING HEIGHTS USE 53” POST. FAILURE TO DO THIS WILL NOT ALLOW POST CAPS TO FIT PROPERLY ON POSTS DUE TO INSUFFICIENT CLEARANCE. » IF ATTACHING TREX ENHANCE STEEL RAILING TO PRESSURE-TREATED POST OR PRESSURE-TREATED POST/POST SLEEVES, ATTACH BRACKETS TO POSTS USING #10 X 2.5” HIGH CARBON STEEL COATED BLACK SCREWS (NOT INCLUDED) . » T REX SIGNATURE GLASS RAILINGS ARE DESIGNED TO BE ATTACHED WITH POSTS INSTALLED AT A MAXIMUM CLEAR SPAN OF 6’ (1.83M). » S IGNATURE (BLACK ONLY) POSTS, SELECT ALUMINUM POST, AND ENHANCE STEEL POST CAN BE PURCHASED WITH BRACKETS PREINSTALLED.

SIGNATURE ALUMINUM POSTS (BLACK ONLY): SKU NUMBER

DESCRIPTION Signature Post 37" Corner Post Signature Post 37" End Post Signature Post 37" Inline Post

SKU NUMBER BKAL252543RCAPCNR2G BKAL252543RCAPEND2G BKAL252543RCAPLINE2G

DESCRIPTION SIGNATURE POST 43" Corner Post Signature Post 43" End Post Signature Post 43" Inline Post

BKAL252537RCAPCNR2G BKAL252537RCAPEND2G BKAL252537RCAPLINE2G ENHANCE STEEL POSTS: SKU NUMBER BKSTL202043ENPCNR BKSTL202043ENPLINE BKSTL202043ENPEND SELECT ALUMINUM POSTS: SKU NUMBER

DESCRIPTION 43" Black Steel Enhance Corner Post 43" Black Steel Enhance Line Post 43" Black Steel Enhance End Post DESCRIPTION 2.5” X 2.5" X 37" BKAL SEL End Post 2.5” X 2.5" X 37" BK AL SEL Line Post 2.5” X 2.5" X 37" BK AL SEL Corner Post 2.5” X 2.5" X 43" BK AL SEL End Post 2.5” X 2.5" X 43" BK AL SEL Line Post 2.5” X 2.5" X 43" BK AL SEL Corner Post

SKU NUMBER BKSTL202037ENPCNR BKSTL202037ENPLINE BKSTL202037ENPEND

DESCRIPTION 37" Black Steel Enhance Corner Post 37" Black Steel Enhance Line Post 37" Black Steel Enhance End Post DESCRIPTION 2.5" X 2.5" X 37" BN AL SEL End Post 2.5" X 2.5" X 37" BN AL SEL Line Post 2.5" X 2.5" X 37" BN AL SEL Corner Post 2.5" X 2.5" X 43" BN AL SEL End Post 2.5" X 2.5" X 43" BN AL SEL Line Post 2.5" X 2.5" X 43" BN AL SEL Corner Post

SKU NUMBER BBSAL2537PEND BBSAL2537PLINE BBSAL2537PCNR BBSAL2543PEND BBSAL2543PLINE BBSAL2543PCNR

BKSAL2537PEND BKSAL2537PLINE BKSAL2537PCNR BKSAL2543PEND BKSAL2543PLINE BKSAL2543PCNR

9

LIGHT-OVERVIEW-1026

TREX® LIGHTING–POST SLEEVE

Follow Instructions below for all Pressure-Treated Post with Composite and Aluminum Sleeves Unless Otherwise Stated**

4 x 4 Composite Post Sleeve 6 x 6 Composite Post Sleeve All-in-One Composite Post Sleeve Aluminum Post Sleeve

INSTALLING PRESSURE-TREATED POSTS 1. .Review COMPATIBLE POST WITH LIGHTING CHART to determine the correct composite sleeve that is suitable with lighted post cap, under rail lighting, as well as approved railing systems used.

2. R efer to local building code requirements prior to attaching pressure-treated posts.

PREPARING POST SLEEVES FOR LIGHTED POST CAPS 3. E nsure wiring is installed to pressure-treated post as previously outlined in instructions. PREPARING POST SLEEVES FOR UNDER-RAIL LIGHTING

4

4. If installing under-rail lighting, drill a 1/2" hole through deck board at wire location. Drill hole directly beside pressure-treated post to allow for post skirt to hide hole location. Note: This step might not be necessary if there is a large enough gap between deck board and pressure-treated post.

10

LIGHT-OVERVIEW-1026

TREX® LIGHTING–POST SLEEVE/ CONTINUED Use information on the following tables to locate bracket and under rail light placements on post sleeves (with the exception for Select and Enhance Railing as noted) for desired railings being installed, post sleeves are not installed over pressure-treated posts until after this step is completed. DO NOT INSTALL BRACKETS AT THIS STEP.

TRANSCEND RAILING HORIZONTAL RAILING BRACKET AND UNDER RAIL LIGHT LOCATIONS

Bottom Bracket Location

Top Bracket Location 36"

Top Bracket Location 42"

Transcend Standard

5-1/2" 5-1/2”

35-1/16" 36-3/16”

41-1/16" 42-3/16”

Transcend Cocktail-Over the Post

5c

5a

Bottom of post sleeve

5-1/2"

See Table

5a. U sing table above, mark locations for brackets at all required locations.

5c. If installing a post sleeve that has a one-piece skirt, slide one-piece skirt over pressure-treated post.

5b

3-1/2"

5b. M easure 4" from bottom of post sleeve and drill a 1/2" hole under the location of the lower bracket being used.

Note: Do this at all locations where under-rail lighting is being installed.

11

LIGHT-OVERVIEW-1026

TREX® LIGHTING–POST SLEEVE/ CONTINUED

SELECT / ENHANCE RAILING - UNDER RAIL LIGHT LOCATION

Note: For Select Classic, Select T-Rail, and Enhance Railings, brackets are installed on rails first so bracket placement does not apply here.

6a

6b. If installing a post sleeve that has a one-piece skirt, slide one-piece skirt over pressure-treated post.

2-1/4"

6a. F or Select Classic, Select T-Rail, or Enhance Composite railing, measure 2-1/4" from bottom of post sleeve, and drill 1/2" hole. Do this at all locations where under-rail lighting is being installed.

SIGNATURE - STANDARD / ROD RAIL / MESH RAIL, GLASS RAIL HORIZONTAL RAILING BRACKET AND UNDER RAIL LIGHT LOCATIONS Bottom Bracket Location Top Bracket Location 36"

Top Bracket Location 42"

Signature/Rod Rail/Mesh/Glass*–Horizontal Fixed Bracket

1-7/8"

34-1/2"

40-1/2"

7b

7a

Bottom of post sleeve

1-5/8"

1-7/8"

See Table

7a. U sing table above, mark locations for brackets at all required locations.

7b. Measure 1-5/8" from bottom of post sleeve and drill a 1/2" hole under the location of the lower bracket being used.

Note: Do this at all locations where under-rail lighting is being installed.

7c. If installing a post sleeve that has a one-piece skirt, slide one-piece skirt over pressure-treated post.

12

LIGHT-OVERVIEW-1026

TREX® LIGHTING–POST SLEEVE/ CONTINUED

SELECT ALUMINUM RAILING BRACKET AND UNDER RAIL LIGHT LOCATIONS

Bottom Bracket Location

Top Bracket Location 36"

Top Bracket Location 42"

Select Aluminum–Horizontal Fixed Bracket

3-9/16"

34-7/8"

40-7/8"

8b

8a

Bottom of post sleeve

3-5/16"

3-9/16"

See Table

8a. U sing table above, mark locations for brackets at all required locations.

8b. M easure 3-5/16" from bottom of post sleeve and drill a 1/2" hole under the location of the lower bracket being used.

Note: Do this at all locations where under-rail lighting is being installed.

8c. If installing a post sleeve that has a one-piece skirt, slide one-piece skirt over pressure-treated post.

13

LIGHT-OVERVIEW-1026

TREX® LIGHTING–POST SLEEVE/ CONTINUED

ENHANCE STEEL RAILING BRACKET AND UNDER RAIL LIGHT LOCATIONS

Bottom Bracket Location

Top Bracket Location 36"

Top Bracket Location 42"

Enhance Steel–Horizontal Fixed Bracket

3-3/8"

35-1/8"

41-1/8"

9b

Bottom of post sleeve 9a

3-1/8"

3-3/8"

See Table

9a. U sing table above, mark locations for brackets at all required locations.

9b. M easure 3-1/8" from bottom of post sleeve and drill a 1/2" hole under the location of the lower bracket being used.

Note: Do this at all locations where under-rail lighting is being installed.

9c. If installing a post sleeve that has a one-piece skirt, slide one-piece skirt over pressure-treated post.

14

LIGHT-OVERVIEW-1026

TREX® LIGHTING–POST SLEEVE BRACKET INSTALLATION

10

Installation of Brackets to Sleeves

Transcend Railing–Bracket Installation 13a. Install RSB’s UNDER marks, center on posts, and secure with two 2" wood screws (provided). Place top RSBs flat side up, bottom RSBs flat side down. If using a 6 x 6 post sleeve, secure RBS’s to post with two 2-1/2" wood screws that are provided with the 6 x 6 post sleeve.

10. If one-piece skirts were used (not shown), ensure these are in place before proceeding. Thread under-rail wiring through drilled hole on post sleeve as shown. Place post sleeve on pressure-treated post, keeping under rail light positioned so this and the wiring does not get damaged. Use shims if necessary to plum posts. If installing multiple under-rail lights install on all required sides.

11. Snap two-piece skirt on post sleeve.

Note: if there is clearance issue with hole/wiring and any skirt, trimming skirt may be required.

13b. Use instructions for designated railing to complete lighting installation.

12

Select Classic, Select T-Rail, Enhance Composite–Bracket Installation 14a. Not applicable at this stage. Refer to detailed instructions as brackets are attached to rails first and not posts.

14b. Use instructions for designated railing to complete lighting installation.

12. E nsure the opposite end of wiring is placed either through the notched blocking (if required) under the sleeve or through the drilled-out hole on the deck board. Use painters tape or equivalent and tape under-rail light to side of post sleeve.

15

LIGHT-OVERVIEW-1026

TREX® LIGHTING–POST SLEEVE BRACKET INSTALLATION/ CONTINUED

Signature/Rod Rail/Mesh/Glass– Lower Bracket Installation

Signature/Rod Rail/Mesh/Glass– Upper Bracket Installation

15a. C enter lower bracket on post ABOVE the marked line and attach using two 2" (5.1 cm) wood screws (provided) . If using 6 x 6 post sleeve secure brackets with two 2-1/2" wood screws that are provided with the 6 x 6 post sleeve.

15b. C enter upper bracket on post ABOVE the marked line and attach using three 2" (5.1 cm) wood screws (provided). If using 6 x 6 post sleeve secure brackets with two 2-1/2" wood screws that are provided with the 6 x 6 post sleeve.

15c. U se instructions for designated railing to complete lighting installation.

16

LIGHT-OVERVIEW-1026

TREX® LIGHTING–POST SLEEVE BRACKET INSTALLATION/ CONTINUED

Select Aluminum Railing– Lower Bracket Installation

Select Aluminum Railing– Upper Bracket Installation

16a. C enter lower bracket on post ABOVE the marked line and attach using two #10 x 1-3/4" stainless steel screws.

16b. Center upper bracket on post ABOVE marked line and attach using four #10 x 1-3/4" stainless steel screws.

16c. U se instructions for designated railing to complete lighting installation.

17

LIGHT-OVERVIEW-1026

TREX® LIGHTING–POST SLEEVE BRACKET INSTALLATION/ CONTINUED

Enhance Steel Railing– Lower Bracket Installation

Enhance Steel Railing– Upper Bracket Installation

17a. C enter lower bracket on post ABOVE the marked line and attach using two #10 x 2.5" high carbon steel coated black screws (not provided).

17b. C enter upper bracket on post ABOVE marked line and attach using two #10 x 2.5" high carbon steel coated black screws (not provided).

17c. Use instructions for designated railing to complete lighting installation.

18

LIGHT-OVERVIEW-1026

TREX® LIGHTING–METAL/ALUMINUM/ENHANCE STEEL POST/PREPARATION

5

Follow Instructions below for all Metal Post Mounts Unless Otherwise Stated Signature Aluminum Rail Post Select Aluminum Rail Post Enhance Steel Rail Post PREPARING METAL POSTS FOR LIGHTED POST CAPS AND UNDER RAIL LIGHTING 1 Review COMPATIBLE POST WITH LIGHTING CHART to determine the metal posts that are suitable with lighted post cap, under rail lighting, as well as approved railing systems used. 2. E nsure proper blocking has been installed as per requirements set forth in detailed product railing post installation instructions.

5. W hen installing Signature or Select Aluminum posts, drill through decking and blocking using long 1/2" drill bit. When installing Enhance Steel posts, drill through decking and blocking using a long 9/16" drill bit. 6. If installing lighting and using posts that require bracket installation, use information as outlined or use Trex designated templates to locate bracket placement. All measurements listed are from the DECKING SURFACE.

3

7. Attach Posts per posts instructions.

3. U sing post as template, place post in desired location, and mark location of mounting bolts.

4

4. S et post aside and use an “X” pattern between marked locations, and mark center location.

19

LIGHT-OVERVIEW-1026

TREX® LIGHTING–METAL POST BRACKET INSTALLATION

Signature Post–Bracket Installation

Horizontal Railing Bracket Placement– Metal Post Signature / Rod Rail / Mesh / Glass– Horizontal Fixed Bracket

Bottom Bracket Location

Top Bracket Location 36"

Top Bracket Location 42"

1-7/8"

34-1/2"

40-1/2"

All bracket locations are measured from decking surface and are to be placed ABOVE measured/marked lines.

Signature Post– Lower Bracket Installation

Signature Post– Upper Bracket Installation

8a. F or lower fixed bracket, center lower bracket on post ABOVE the marked line and attach using two self-tapping screws (provided) .

8b. For upper fixed bracket, center upper bracket on post ABOVE marked line and attach using three self-tapping screws (provided).

20

LIGHT-OVERVIEW-1026

TREX® LIGHTING–ALUMINUM POST BRACKET INSTALLATION

Select Aluminum–Bracket Installation

Horizontal Railing Bracket Placement– Metal Post Select Aluminum–Horizontal Fixed Bracket

Bottom Bracket Location

Top Bracket Location 36"

Top Bracket Location 42"

3-9/16" 40-7/8" All bracket locations are measured from decking surface and are to be placed ABOVE measured/marked lines. 34-7/8"

Select Aluminum– Lower Bracket Installation

Select Aluminum– Upper Bracket Installation

9a. F or lower ABOVE bracket, center lower bracket on post above the marked line and attach using two #10 x 3/4” self-drilling screws (provided) .

9b. F or upper fixed bracket, center upper bracket on post ABOVE marked line and attach using four #10 x 3/4” self-drilling screws (provided) .

21

LIGHT-OVERVIEW-1026

TREX® LIGHTING–ENHANCE STEEL BRACKET INSTALLATION

Enhance Steel–Bracket Installation

Horizontal Railing Bracket Placement– Metal Post Enhance Steel–Horizontal Fixed Bracket

Bottom Bracket Location

Top Bracket Location 36"

Top Bracket Location 42"

3-3/8" 41-1/8" All bracket locations are measured from decking surface and are to be placed ABOVE measured/marked lines. 35-1/8"

Enhance Steel– Lower Bracket Installation

Enhance Steel– Upper Bracket Installation

10a. Center lower fixed bracket on post ABOVE the marked line and attach using two #12 x 3/4” self- drilling screws (provided).

10b. C enter upper fixed bracket on post ABOVE marked line and attach using two #12 x 3/4” self-drilling screws (provided).

22

LIGHT-OVERVIEW-1026

TREX® LIGHTING–METAL/ALUMINUM/ENHANCE STEEL POST/ CONTINUED UNDER-RAIL LIGHT TO POST INSTALLATION

13. U se instructions for designated railing to complete lighting installation.

11

11. D rill a 1/2" hole under the location of underside of the lower bracket being used. Do this at all locations where under-rail lighting is being installed. In some cases the skirt might interfere with this hole location, so slight trimming of the skirt may be required.

12

12. T hread under-rail wiring through drilled hole on metal post, and through pre-drill hole in decking and blocking. TIP: If wiring is difficult to thread through hole in bottom of post, this opening can be drilled out and opened slightly to accommodate all wiring. Install posts as outlined in detailed railing installation instructions, keeping under-rail light positioned so this does not get damaged.

TIP: Using painters tape or equivalent, tape under-rail light to side of metal post.

23

LIGHT-OVERVIEW-1026

TREX® LIGHTING–X-SERIES LIGHTED POST CAPS INSTALLATION

4

Follow Instructions below for Signature X-Series Post

Signature X-Series Anchor Post

PREPARING X-SERIES ANCHOR POSTS FOR LIGHTED POST CAPS

1. E nsure proper blocking has been installed as per requirements set forth in the X-Series Post instructions.

2

4. U sing post as template, place post in desired location, and mark location of mounting bolts and wiring hole.

5

No cable installation at this location

5. S et post aside and drill through decking and blocking using same 9/16” long drill bit.

6

2. R emove one channel cover from side of post, ensuring this location is not the same as where cable railing is being installed. See example.

3

3. L ocate and drill 9/16" hole through the bottom of baseplate.

6. P lace wire in the channel of the post and thread through pre-drilled hole in baseplate, decking and blocking.

24

LIGHT-OVERVIEW-1026

TREX® LIGHTING–X-SERIES LIGHTED POST CAPS INSTALLATION/ CONTINUED

INSTALLING X-SERIES ANCHOR POSTS AND LIGHTED POST CAP

7. Attach posts as per X-Series post instructions.

8. C onnect all wiring as required and press lighted post cap on X-Series anchor post.

9

9 R eplace the channel cover.

25

LIGHT-OVERVIEW-1026

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25

Made with FlippingBook Annual report maker